HL incident on 2016-05-05 — CA
Operator
Thums Long Beach Co
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$7,000
Incident datetime
2016-05-05 19:20
Report number
Location
CA
Narrative
On thursday, may 5th at approximately 7:20pm, a tidelands operator discovered a leak while conducting routine rounds. Approximately 3 barrels of crude oil was released from the pipeline, with product being cleaned up and recovered with the assistance of a vacuum truck. Contaminated soils are being removed from the area where the leak occurred. The leak was contained on company property.
Detailed record list
Report Received Date
2016-06-03 00:00:00
Iyear
2016
Report Number
20160168
Supplemental Number
21879
Report Type
Supplemental Final
Operator Id
19410
Name
Thums Long Beach Co
Operator Street Address
One World Trade Center Suite 1500
Operator City Name
Long Beach
Operator State Abbreviation
CA
Operator Postal Code
90831
Local Datetime
2016-05-05 19:15:00
Location Latitude
33.758661
Location Longitude
-118.203322
Commodity Released Type
Crude Oil
Unintentional Release Bbls
2.98
Recovered Bbls
2.98
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
Incident Identified Datetime
2016-05-05 19:20:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2016-05-05 19:30:00
Restart Datetime
2016-09-13 13:00:00
On Site Datetime
2016-05-05 19:20:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Parcel A Lease
Segment Name
Jl-1
Onshore State Abbreviation
Ca
Onshore Postal Code
90802
Onshore City Name
Long Beach
Onshore County Name
Los Angeles
Designated Location
Survey Station No.
Designated Name
Cp 51
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
108
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
20
Pipe Wall Thickness
0.375
Pipe Smys
35000
Pipe Specification
Api 5l Grade B
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Installation Year
1966
Manufactured Year
1965
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Commercially Nav Ind
Yes
Commercially Nav Yes No
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
120
Est Cost Prop Damage
7000
Est Cost Emergency
3000
Est Cost Environmental
0
Est Cost Other
0
Prpty
10120
Accident Psig
95
Mop Psig
132
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
9291
Internal Inspection Ind
No
Diameter Change Ind
Yes
Tight Mitered Ind
Yes
Operation Complications Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Corrosion identified as root cause
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
Unknown
Shielding Evident
No
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2015
Close Interval Survey Year
2015
Prior Damage
No
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2016
Hydrtst Most Rcnt Pressure
170
Direct Asmnt Conducted
No
Non Destructive Exam Ind
Yes
Exm Wave Ultrasonic Rcnt Year
2016
Exm Handl Ultrasonic Rcnt Year
2016
Exm Wave Ultrasonic Rcnt Ind
Yes
Exm Handl Ultrasonic Rcnt Ind
Yes
Preparer Name
C***** C********
Preparer Title
Mi Engineer - Piping
Preparer Email
C***************@c**.com
Preparer Telephone
562-277-5099
Preparer Fax
562-624-3499
Prepared Date
2016-11-21 00:00:00
Authorizer Name
C****** P****
Authorizer Telephone
562-624-3202
Authorizer Title
Vp Operations
Authorizer Email
C************@c**.com
Narrative
On thursday, may 5th at approximately 7:20pm, a tidelands operator discovered a leak while conducting routine rounds. Approximately 3 barrels of crude oil was released from the pipeline, with product being cleaned up and recovered with the assistance of a vacuum truck. Contaminated soils are being removed from the area where the leak occurred. The leak was contained on company property.
| Report Received Date | 2016-06-03 00:00:00 |
|---|---|
| Iyear | 2016 |
| Report Number | 20160168 |
| Supplemental Number | 21879 |
| Report Type | Supplemental Final |
| Operator Id | 19410 PHMSA Enforcement |
| Name | Thums Long Beach Co |
| Operator Street Address | One World Trade Center Suite 1500 |
| Operator City Name | Long Beach |
| Operator State Abbreviation | CA |
| Operator Postal Code | 90831 |
| Local Datetime | 2016-05-05 19:15:00 |
| Location Latitude | 33.758661 Google Maps OpenStreetMap |
| Location Longitude | -118.203322 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 2.98 |
| Recovered Bbls | 2.98 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Ground Patrol By Operator Or Its Contractor |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2016-05-05 19:20:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2016-05-05 19:30:00 |
| Restart Datetime | 2016-09-13 13:00:00 |
| On Site Datetime | 2016-05-05 19:20:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Parcel A Lease |
| Segment Name | Jl-1 |
| Onshore State Abbreviation | Ca |
| Onshore Postal Code | 90802 |
| Onshore City Name | Long Beach |
| Onshore County Name | Los Angeles |
| Designated Location | Survey Station No. |
| Designated Name | Cp 51 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 108 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 20 |
| Pipe Wall Thickness | 0.375 |
| Pipe Smys | 35000 |
| Pipe Specification | Api 5l Grade B |
| Pipe Seam Type | Seamless |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1966 |
| Manufactured Year | 1965 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| Commercially Nav Ind | Yes |
| Commercially Nav Yes No | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 120 |
| Est Cost Prop Damage | 7000 |
| Est Cost Emergency | 3000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 10120 |
| Accident Psig | 95 |
| Mop Psig | 132 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 9291 |
| Internal Inspection Ind | No |
| Diameter Change Ind | Yes |
| Tight Mitered Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Corrosion identified as root cause |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Galvanic Corrosion Ind | Yes |
| Field Exam Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | Yes |
| Cathodic Pro Start Year | Unknown |
| Shielding Evident | No |
| Cathodic Survey Type | Yes |
| Cp Annual Survey Ind | Yes |
| Close Interval Survey Ind | Yes |
| Cp Annual Survey Year | 2015 |
| Close Interval Survey Year | 2015 |
| Prior Damage | No |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 2016 |
| Hydrtst Most Rcnt Pressure | 170 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | Yes |
| Exm Wave Ultrasonic Rcnt Year | 2016 |
| Exm Handl Ultrasonic Rcnt Year | 2016 |
| Exm Wave Ultrasonic Rcnt Ind | Yes |
| Exm Handl Ultrasonic Rcnt Ind | Yes |
| Preparer Name | C***** C******** |
| Preparer Title | Mi Engineer - Piping |
| Preparer Email | C***************@c**.com |
| Preparer Telephone | 562-277-5099 |
| Preparer Fax | 562-624-3499 |
| Prepared Date | 2016-11-21 00:00:00 |
| Authorizer Name | C****** P**** |
| Authorizer Telephone | 562-624-3202 |
| Authorizer Title | Vp Operations |
| Authorizer Email | C************@c**.com |
| Narrative | On thursday, may 5th at approximately 7:20pm, a tidelands operator discovered a leak while conducting routine rounds. Approximately 3 barrels of crude oil was released from the pipeline, with product being cleaned up and recovered with the assistance of a vacuum truck. Contaminated soils are being removed from the area where the leak occurred. The leak was contained on company property. |