HL incident on 2015-06-19 — TX

Operator
Wyoming Pipeline Company
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$1,200
Incident datetime
2015-06-19 08:00
Report number
Location
TX
Narrative
Air patrol discovered the leak on routine flight. Maintenance crew dug up leak with backhoe, repaired pipe where a buried rock was discovered causing a holiday in the coating that caused a pinhole corrosion leak in the pipe. Inspected creek further; crude oil traveled 2 miles down stream; booms were set up a vac truck was called in to begin cleaning up oil. Sent in a burn request to wy deq. Received verbal permission for the burn; burn began on 6-22-15 @ 08:30 am. An estimated 1 barrel of crude oil was burned with the remaining 1 barrel collected in excavated soil that was disposed of with new soil being placed in the excavation. Local authorities and landowners were notified. Water depth stated as 1.0 feet because a lesser depth could not be entered. Creek depth was 8 to 10 inches deep at the time. The creek crossing is generally dry.
Detailed record list
Report Received Date
2016-05-25 00:00:00
Iyear
2015
Report Number
20160157
Supplemental Number
30552
Report Type
Supplemental Final
Operator Id
Name
Wyoming Pipeline Company
Operator Street Address
825 Town & Country Lane
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77024
Local Datetime
2015-06-19 08:00:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
2
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Air Patrol
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2015-06-19 08:00:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Line Was Repaired Using A Leak Clamp While In Service
On Site Datetime
2015-06-19 08:30:00
Nrc Rpt Datetime
2015-06-19 14:34:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Wyoming Pipeline Co.
Segment Name
Main Line/butte Jct To Wrc
Onshore State Abbreviation
Wy
Onshore Postal Code
82701
Onshore City Name
Not Within A Municipality
Onshore County Name
Weston
Designated Location
Milepost/valve Station
Designated Name
4 Milepost
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
34
Crossing
Yes
Water Crossing Ind
Yes
Water Type
Cased
Water Name
Little Oil Creek
Water Depth
1
Water Subtype
Shoreline/bank Crossing
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
6
Pipe Wall Thickness
0.125
Pipe Smys
56000
Pipe Specification
Api Sl X52 Erw
Pipe Seam Type
Erw � Unknown Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Cold Applied Tape
Installation Year
1969
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Surface Water Remed Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
2
Rel Water Name
Little Oil Creek
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
100
Est Cost Prop Damage
1200
Est Cost Emergency
7185
Est Cost Environmental
4000
Est Cost Other
0
Prpty
12485
Accident Psig
200
Mop Psig
400
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
24288
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
=< 20% Smys Regulated Gathering
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Volume of the leak would not be detectable on the scada system
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
General Corrosion
Microbiological Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
Unknown
Shielding Evident
Unknown
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Other Cp Survey Ind
Yes
Cp Annual Survey Year
2015
Close Interval Survey Year
2014
Other Cp Survey Year
2014
Prior Damage
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
M***** E*****
Preparer Title
Logistics Manager
Preparer Email
M******@p*********.com
Preparer Telephone
3077469803
Prepared Date
2018-06-27 00:00:00
Authorizer Name
M***** E*****
Authorizer Telephone
3077469803
Authorizer Title
Logistics Manager
Authorizer Email
M******@p*********.com
Narrative
A****************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************@ 08:30 am. An estimated 1 barrel of crude oil was burned with the remaining 1 barrel collected in excavated soil that was disposed of with new soil being placed in the excavation. Local authorities and landowners were notified. Water depth stated as 1.0 feet because a lesser depth could not be entered. Creek depth was 8 to 10 inches deep at the time. ************************************.
Report Received Date 2016-05-25 00:00:00
Iyear 2015
Report Number 20160157
Supplemental Number 30552
Report Type Supplemental Final
Operator Id 32537 PHMSA Enforcement
Name Wyoming Pipeline Company
Operator Street Address 825 Town & Country Lane
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77024
Local Datetime 2015-06-19 08:00:00
Location Latitude 43.841176 Google Maps OpenStreetMap
Location Longitude -104.255425 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 2
Recovered Bbls 1
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Air Patrol
Operator Type Contractor Working For The Operator
Incident Identified Datetime 2015-06-19 08:00:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind No
Shutdown Explain Line Was Repaired Using A Leak Clamp While In Service
On Site Datetime 2015-06-19 08:30:00
Nrc Rpt Datetime 2015-06-19 14:34:00
Nrc Rpt Num 1120320 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Wyoming Pipeline Co.
Segment Name Main Line/butte Jct To Wrc
Onshore State Abbreviation Wy
Onshore Postal Code 82701
Onshore City Name Not Within A Municipality
Onshore County Name Weston
Designated Location Milepost/valve Station
Designated Name 4 Milepost
Federal No
Location Type Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 34
Crossing Yes
Water Crossing Ind Yes
Water Type Cased
Water Name Little Oil Creek
Water Depth 1
Water Subtype Shoreline/bank Crossing
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 6
Pipe Wall Thickness 0.125
Pipe Smys 56000
Pipe Specification Api Sl X52 Erw
Pipe Seam Type Erw � Unknown Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Cold Applied Tape
Installation Year 1969
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Surface Water Remed Ind Yes
Soil Remed Ind Yes
Water Contam Ind Yes
Surface Contam Ind Yes
Amount Released 2
Rel Water Name Little Oil Creek
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 100
Est Cost Prop Damage 1200
Est Cost Emergency 7185
Est Cost Environmental 4000
Est Cost Other 0
Prpty 12485
Accident Psig 200
Mop Psig 400
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 24288
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function =< 20% Smys Regulated Gathering
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Volume of the leak would not be detectable on the scada system
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results General Corrosion
Microbiological Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year Unknown
Shielding Evident Unknown
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Other Cp Survey Ind Yes
Cp Annual Survey Year 2015
Close Interval Survey Year 2014
Other Cp Survey Year 2014
Prior Damage Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name M***** E*****
Preparer Title Logistics Manager
Preparer Email M******@p*********.com
Preparer Telephone 3077469803
Prepared Date 2018-06-27 00:00:00
Authorizer Name M***** E*****
Authorizer Telephone 3077469803
Authorizer Title Logistics Manager
Authorizer Email M******@p*********.com
Narrative A****************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************@ 08:30 am. An estimated 1 barrel of crude oil was burned with the remaining 1 barrel collected in excavated soil that was disposed of with new soil being placed in the excavation. Local authorities and landowners were notified. Water depth stated as 1.0 feet because a lesser depth could not be entered. Creek depth was 8 to 10 inches deep at the time. ************************************.

All rights reserved. Copyright © by ClearPHMSA