HL incident on 2016-04-16 — TX

Operator
Phillips 66 Pipeline Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$15,000
Incident datetime
2016-04-16 23:30
Report number
Location
TX
Narrative
At approximately 11:30 pm on saturday, april 16, a leak occurred on the 12-inch hs&p to orcutt segment of line 300. The leak occurred on a third party crude oil production facility about two miles south of vandenberg village, california. The pipeline was shut down and the appropriate regulatory agencies were notified. The spill is contained on the third party's production facility property and does not pose a threat to the public or the surrounding environment. Supplemental report: changed part b question 10 to "pipeline right of way"
Detailed record list
Report Received Date
2016-05-16 00:00:00
Iyear
2016
Report Number
20160146
Supplemental Number
21908
Report Type
Supplemental Final
Operator Id
Name
Phillips 66 Pipeline Llc
Operator Street Address
2331 Citywest Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Local Datetime
2016-04-16 23:30:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
18
Recovered Bbls
18
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2016-04-16 23:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2016-04-16 23:30:00
Restart Datetime
2016-04-26 15:00:00
On Site Datetime
2016-04-16 23:30:00
Nrc Rpt Datetime
2016-04-17 20:00:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Hs&p
Segment Name
Cc-30
Onshore State Abbreviation
Ca
Onshore Postal Code
93436
Onshore City Name
Lompoc
Onshore County Name
Santa Barbara
Designated Location
Milepost/valve Station
Designated Name
0
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
120
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Other
Item Involved Details
Fitting Elbow / 90
Installation Year
1986
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
30000
Est Cost Gas Released
720
Est Cost Prop Damage
15000
Est Cost Emergency
222000
Est Cost Environmental
75000
Est Cost Other
0
Prpty
342720
Accident Psig
598
Mop Psig
895
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
15312
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Localized external pit corrosion.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1986
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2015
Prior Damage
Yes
Preparer Name
B**** G****
Preparer Title
Dot Coordinator
Preparer Email
B**********@p**.com
Preparer Telephone
909-241-3358
Preparer Fax
562-290-1580
Prepared Date
2016-12-02 00:00:00
Authorizer Name
T*** F****
Authorizer Telephone
832-765-1632
Authorizer Title
Director Dot Compliance
Authorizer Email
M***********@p**.com
Narrative
At approximately 11:30 pm on saturday, april 16, a leak occurred on the 12-inch hs&p to orcutt segment of line 300. The leak occurred on a third party crude oil production facility about two miles south of vandenberg village, california. The pipeline was shut down and the appropriate regulatory agencies were notified. The spill is contained on the third party's production facility property and does not pose a threat to the public or the surrounding environment. Supplemental report: changed part b question 10 to "pipeline right of way"
Report Received Date 2016-05-16 00:00:00
Iyear 2016
Report Number 20160146
Supplemental Number 21908
Report Type Supplemental Final
Operator Id 31684 PHMSA Enforcement
Name Phillips 66 Pipeline Llc
Operator Street Address 2331 Citywest Blvd
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77042
Local Datetime 2016-04-16 23:30:00
Location Latitude 34.723949 Google Maps OpenStreetMap
Location Longitude -120.433842 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 18
Recovered Bbls 18
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2016-04-16 23:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2016-04-16 23:30:00
Restart Datetime 2016-04-26 15:00:00
On Site Datetime 2016-04-16 23:30:00
Nrc Rpt Datetime 2016-04-17 20:00:00
Nrc Rpt Num 1145487 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Remotely Controlled
Downstream Valve Type Ind Remotely Controlled
Num Pub Evacuated 0
Pipe Fac Name Hs&p
Segment Name Cc-30
Onshore State Abbreviation Ca
Onshore Postal Code 93436
Onshore City Name Lompoc
Onshore County Name Santa Barbara
Designated Location Milepost/valve Station
Designated Name 0
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Pavement
Depth Of Cover 120
Crossing No
Pipe Facility Type Intrastate
Item Involved Other
Item Involved Details Fitting Elbow / 90
Installation Year 1986
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 30000
Est Cost Gas Released 720
Est Cost Prop Damage 15000
Est Cost Emergency 222000
Est Cost Environmental 75000
Est Cost Other 0
Prpty 342720
Accident Psig 598
Mop Psig 895
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 15312
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Localized external pit corrosion.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1986
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Cp Annual Survey Year 2015
Prior Damage Yes
Preparer Name B**** G****
Preparer Title Dot Coordinator
Preparer Email B**********@p**.com
Preparer Telephone 909-241-3358
Preparer Fax 562-290-1580
Prepared Date 2016-12-02 00:00:00
Authorizer Name T*** F****
Authorizer Telephone 832-765-1632
Authorizer Title Director Dot Compliance
Authorizer Email M***********@p**.com
Narrative At approximately 11:30 pm on saturday, april 16, a leak occurred on the 12-inch hs&p to orcutt segment of line 300. The leak occurred on a third party crude oil production facility about two miles south of vandenberg village, california. The pipeline was shut down and the appropriate regulatory agencies were notified. The spill is contained on the third party's production facility property and does not pose a threat to the public or the surrounding environment. Supplemental report: changed part b question 10 to "pipeline right of way"

All rights reserved. Copyright © by ClearPHMSA