GD incident on 2016-10-26 — TN

Operator
Atmos Energy Corporation - Ky/mid-States (Mid-States)
Cause
Equipment Failure
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$10,000
Incident datetime
2016-10-26 09:30
Report number
Location
TN, WILLIAMSON
Narrative
The leak occurred during the attempted installation of a 2' x 3/4' electrofusion tap tee on to a 2' hdpe main. All of the materials and equipment used during the attempted installation were destroyed by fire, leaving no evidence to examine. The electrofusion process provided heat that apparently compromised the pipe.
Detailed record list
Occurred At
2016-10-26 09:30:00
Year
2016
Report Received Date
2016-12-02 00:00:00
Iyear
2016.0
Report Number
20160123.0
Supplemental Number
30427.0
Report Type
Supplemental Final
Operator Id
Name
Atmos Energy Corporation - Ky/mid-States (Mid-States)
Operator Street Address
5430 Lbj Freeway Suite 1800
Operator City Name
Dallas
Operator State Abbreviation
TX
Operator Postal Code
75240
Local Datetime
2016-10-26 09:30:00
Location Street Address
1147 Eckerton Dr
Location City Name
Nolensville
Location County Name
Williamson
Location State Abbreviation
TN
Location Postal Code
37135
Location Latitude
Location Longitude
Nrc Rpt Datetime
2016-10-26 10:45:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
68.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2016-10-26 09:30:00
On Site Datetime
2016-10-26 09:30:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
36.0
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2016.0
Pipe Diameter
2.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Performance
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
3408
Release Type
Leak
Leak Type
Connection Failure
Class Location Type
Class 3 Location
Est Cost Oper Paid
500000.0
Est Cost Prop Damage
10000.0
Est Cost Emergency
10000.0
Est Cost Other
0.0
Est Cost Unintentional Release
250.0
Prpty
520250.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
74.0
Accident Psig
87.0
Normal Psig
90.0
Mop Psig
100.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
Yes
Num Contractors Tested
3
Num Contractors Failed
0
Cause
Equipment Failure
Cause Details
Other Equipment Failure
Eq Failure Type
Other Equipment Failure
Eq Failure Details
The Leak Occurred During The Attempted Installation Of A 2' X 3/4' Electrofusion Tap Tee On To A 2' Hdpe Main. All Of The Materials And Equipment Used During The Attempted Installation Were Destroyed By Fire, Leaving No Evidence To Examine. The Electrofusion Process Provided Heat That Apparently Compromised The Pipe.
Preparer Name
J*** M* S******
Preparer Title
Mgr. Compliance
Preparer Email
J***********@a**********.com
Preparer Telephone
615 771-8387
Authorizer Name
J*** M* S******
Authorizer Title
Mgr. Compliance
Authorizer Telephone
615 771-8387
Authorizer Email
J***********@a**********.com
Narrative
The leak occurred during the attempted installation of a 2' x 3/4' electrofusion tap tee on to a 2' hdpe main. All of the materials and equipment used during the attempted installation were destroyed by fire, leaving no evidence to examine. The electrofusion process provided heat that apparently compromised the pipe.
Occurred At 2016-10-26 09:30:00
Year 2016
Report Received Date 2016-12-02 00:00:00
Iyear 2016.0
Report Number 20160123.0
Supplemental Number 30427.0
Report Type Supplemental Final
Operator Id 20211 PHMSA Enforcement
Name Atmos Energy Corporation - Ky/mid-States (Mid-States)
Operator Street Address 5430 Lbj Freeway Suite 1800
Operator City Name Dallas
Operator State Abbreviation TX
Operator Postal Code 75240
Local Datetime 2016-10-26 09:30:00
Location Street Address 1147 Eckerton Dr
Location City Name Nolensville
Location County Name Williamson
Location State Abbreviation TN
Location Postal Code 37135
Location Latitude 35.94208 Google Maps OpenStreetMap
Location Longitude -86.65972 Google Maps OpenStreetMap
Nrc Rpt Datetime 2016-10-26 10:45:00
Nrc Rpt Num 1162559 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 68.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
Explode Ind No
Num Pub Evacuated 0.0
Incident Identified Datetime 2016-10-26 09:30:00
On Site Datetime 2016-10-26 09:30:00
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 36.0
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Main
Installation Year 2016.0
Pipe Diameter 2.0
Pipe Specification Astm D2513
Pipe Manufacturer Performance
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11
Material Pe Pipe Code 3408
Release Type Leak
Leak Type Connection Failure
Class Location Type Class 3 Location
Est Cost Oper Paid 500000.0
Est Cost Prop Damage 10000.0
Est Cost Emergency 10000.0
Est Cost Other 0.0
Est Cost Unintentional Release 250.0
Prpty 520250.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 74.0
Accident Psig 87.0
Normal Psig 90.0
Mop Psig 100.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind Yes
Num Contractors Tested 3
Num Contractors Failed 0
Cause Equipment Failure
Cause Details Other Equipment Failure
Eq Failure Type Other Equipment Failure
Eq Failure Details The Leak Occurred During The Attempted Installation Of A 2' X 3/4' Electrofusion Tap Tee On To A 2' Hdpe Main. All Of The Materials And Equipment Used During The Attempted Installation Were Destroyed By Fire, Leaving No Evidence To Examine. The Electrofusion Process Provided Heat That Apparently Compromised The Pipe.
Preparer Name J*** M* S******
Preparer Title Mgr. Compliance
Preparer Email J***********@a**********.com
Preparer Telephone 615 771-8387
Authorizer Name J*** M* S******
Authorizer Title Mgr. Compliance
Authorizer Telephone 615 771-8387
Authorizer Email J***********@a**********.com
Narrative The leak occurred during the attempted installation of a 2' x 3/4' electrofusion tap tee on to a 2' hdpe main. All of the materials and equipment used during the attempted installation were destroyed by fire, leaving no evidence to examine. The electrofusion process provided heat that apparently compromised the pipe.

All rights reserved. Copyright © by ClearPHMSA