GD incident on 2016-09-02 — GA
Operator
Atlanta Gas Light Co
Cause
Incorrect Operation
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$34,000
Incident datetime
2016-09-02 20:58
Report number
Location
GA, HALL
Narrative
A 6-inch hp steel main with a bull plug end connected by a style 700 posi-hold compression coupling (marked with a 300 psi pressure rating and tested to 2x working pressure (600 psi) in the factory during production) separated from the main. As a result of the separation, gas service to 452 customers was interrupted to make repairs to the main. At this point it was determined that the incident resulted in a cost meeting the threshold for reporting. Prior to the separation, the main associated with the posi-hold compression coupling experienced an increase in pressure approximately 10 psig above 110% of maop. The over-pressure above the allowed 10% build-up was the result of undersized piping between the regulator and relief valve which limited the amount of flow the relief valve could pass to stay within the necessary tolerance for build-up. The regulator station in question has since been rebuilt where the piping and fittings are adequate for the required over-pressure protection.
Detailed record list
Occurred At
2016-09-02 20:58:00
Year
2016
Report Received Date
2016-10-05 00:00:00
Iyear
2016.0
Report Number
20160101.0
Supplemental Number
31686.0
Report Type
Supplemental Final
Operator Id
Name
Atlanta Gas Light Co
Operator Street Address
10 Peachtree Place Ne
Operator City Name
Atlanta
Operator State Abbreviation
GA
Operator Postal Code
30309
Local Datetime
2016-09-02 20:58:00
Location Street Address
2113 Friendship Road
Location City Name
Buford
Location County Name
Hall
Location State Abbreviation
GA
Location Postal Code
30519
Location Latitude
34.107492
Location Longitude
-83.878376
Nrc Rpt Datetime
2016-09-03 20:14:00
Nrc Rpt Num
1158091
Commodity Released Type
Natural Gas
Unintentional Release
7300.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
2.0
Incident Identified Datetime
2016-09-02 20:58:00
On Site Datetime
2016-09-02 21:39:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
108.0
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Other
System Part Details
6-Inch Posi-Hold Coupling
Installation Year
2011.0
Material Involved
Other
Material Details
6-Inch Posi-Hold Coupling
Release Type
Leak
Leak Type
Connection Failure
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
34000.0
Est Cost Emergency
82730.0
Est Cost Other
0.0
Est Cost Unintentional Release
19856.0
Prpty
136586.0
Commercial Affected
9.0
Industrial Affected
5.0
Residences Affected
438.0
Accident Psig
343.0
Normal Psig
280.0
Mop Psig
300.0
Accident Pressure
Pressure Exceeded The Applicable Allowance In 192.201
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Preliminary investigation determined that the controller(s) and/or control room did not contribute to the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Equipment Not Installed Properly
Operation Type
Equipment Not Installed Properly
Related Failure Follow Ind
Yes
Category Type
Construction
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
R**** M*******
Preparer Title
Lead Compliance Engineer
Preparer Email
R*******@s*********.com
Preparer Telephone
(404) 584-3733
Preparer Fax
(404) 584-4710
Authorizer Name
R****** R L***
Authorizer Title
Managing Director Compliance And Prm
Authorizer Telephone
(404) 585-3552
Authorizer Email
R****@s*********.com
Narrative
A 6-inch hp steel main with a bull plug end connected by a style 700 posi-hold compression coupling (marked with a 300 psi pressure rating and tested to 2x working pressure (600 psi) in the factory during production) separated from the main. As a result of the separation, gas service to 452 customers was interrupted to make repairs to the main. At this point it was determined that the incident resulted in a cost meeting the threshold for reporting. Prior to the separation, the main associated with the posi-hold compression coupling experienced an increase in pressure approximately 10 psig above 110% of maop. The over-pressure above the allowed 10% build-up was the result of undersized piping between the regulator and relief valve which limited the amount of flow the relief valve could pass to stay within the necessary tolerance for build-up. The regulator station in question has since been rebuilt where the piping and fittings are adequate for the required over-pressure protection.
| Occurred At | 2016-09-02 20:58:00 |
|---|---|
| Year | 2016 |
| Report Received Date | 2016-10-05 00:00:00 |
| Iyear | 2016.0 |
| Report Number | 20160101.0 |
| Supplemental Number | 31686.0 |
| Report Type | Supplemental Final |
| Operator Id | 792 PHMSA Enforcement |
| Name | Atlanta Gas Light Co |
| Operator Street Address | 10 Peachtree Place Ne |
| Operator City Name | Atlanta |
| Operator State Abbreviation | GA |
| Operator Postal Code | 30309 |
| Local Datetime | 2016-09-02 20:58:00 |
| Location Street Address | 2113 Friendship Road |
| Location City Name | Buford |
| Location County Name | Hall |
| Location State Abbreviation | GA |
| Location Postal Code | 30519 |
| Location Latitude | 34.107492 Google Maps OpenStreetMap |
| Location Longitude | -83.878376 Google Maps OpenStreetMap |
| Nrc Rpt Datetime | 2016-09-03 20:14:00 |
| Nrc Rpt Num | 1158091 NRC Report How to search |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 7300.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 2.0 |
| Incident Identified Datetime | 2016-09-02 20:58:00 |
| On Site Datetime | 2016-09-02 21:39:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 108.0 |
| Crossing | No |
| Pipe Facility Type | Privately Owned |
| System Part Involved | Other |
| System Part Details | 6-Inch Posi-Hold Coupling |
| Installation Year | 2011.0 |
| Material Involved | Other |
| Material Details | 6-Inch Posi-Hold Coupling |
| Release Type | Leak |
| Leak Type | Connection Failure |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 0.0 |
| Est Cost Prop Damage | 34000.0 |
| Est Cost Emergency | 82730.0 |
| Est Cost Other | 0.0 |
| Est Cost Unintentional Release | 19856.0 |
| Prpty | 136586.0 |
| Commercial Affected | 9.0 |
| Industrial Affected | 5.0 |
| Residences Affected | 438.0 |
| Accident Psig | 343.0 |
| Normal Psig | 280.0 |
| Mop Psig | 300.0 |
| Accident Pressure | Pressure Exceeded The Applicable Allowance In 192.201 |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | Yes |
| Scada Conf Ind | Yes |
| Accident Identifier | Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations) |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Preliminary investigation determined that the controller(s) and/or control room did not contribute to the incident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Incorrect Operation |
| Cause Details | Equipment Not Installed Properly |
| Operation Type | Equipment Not Installed Properly |
| Related Failure Follow Ind | Yes |
| Category Type | Construction |
| Operator Qualification Ind | Yes |
| Qualified Individuals | Yes, They Were Qualified For The Task(S) |
| Preparer Name | R**** M******* |
| Preparer Title | Lead Compliance Engineer |
| Preparer Email | R*******@s*********.com |
| Preparer Telephone | (404) 584-3733 |
| Preparer Fax | (404) 584-4710 |
| Authorizer Name | R****** R L*** |
| Authorizer Title | Managing Director Compliance And Prm |
| Authorizer Telephone | (404) 585-3552 |
| Authorizer Email | R****@s*********.com |
| Narrative | A 6-inch hp steel main with a bull plug end connected by a style 700 posi-hold compression coupling (marked with a 300 psi pressure rating and tested to 2x working pressure (600 psi) in the factory during production) separated from the main. As a result of the separation, gas service to 452 customers was interrupted to make repairs to the main. At this point it was determined that the incident resulted in a cost meeting the threshold for reporting. Prior to the separation, the main associated with the posi-hold compression coupling experienced an increase in pressure approximately 10 psig above 110% of maop. The over-pressure above the allowed 10% build-up was the result of undersized piping between the regulator and relief valve which limited the amount of flow the relief valve could pass to stay within the necessary tolerance for build-up. The regulator station in question has since been rebuilt where the piping and fittings are adequate for the required over-pressure protection. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA