Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2016-05-15 — GA
Operator
Atlanta Gas Light Co
Cause
Notification Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$136,044
Incident datetime
2016-05-15 17:37
Report number
Location
GA, DEKALB
Narrative
A 2-inch plastic main with one-way feed was ruptured by a county water & sewer crew while performing maintenance work. Once the incident was made safe it was identified that mud, water and debris had entered the downstream gas pipeline where crews began running a cleaning pig to clean the pipeline where it was determined that satisfactory results were not being obtained. At this point during evaluations it was determined that the affected pipeline should be replaced where cost of replacement was the direct results of the incident and not improvements to the existing system where the additional cost resulted in the incident exceeding the $50,000 threshold for reporting. Notification of excavation by the excavator was not made to the one-call center before damage occurred.
Detailed record list
Occurred At
2016-05-15 17:37:00
Year
2016
Report Received Date
2016-05-27 00:00:00
Iyear
2016.0
Report Number
20160049.0
Supplemental Number
16307.0
Report Type
Original Final
Operator Id
Name
Atlanta Gas Light Co
Operator Street Address
10 Peachtree Place Ne
Operator City Name
Atlanta
Operator State Abbreviation
GA
Operator Postal Code
30309
Local Datetime
2016-05-15 17:37:00
Location Street Address
1120 Mcconnell Drive
Location City Name
Decatur
Location County Name
Dekalb
Location State Abbreviation
GA
Location Postal Code
30033
Location Latitude
33.811634
Location Longitude
-84.312419
Nrc Rpt Datetime
2016-05-16 18:01:00
Nrc Rpt Num
1147911
Commodity Released Type
Natural Gas
Unintentional Release
560.04
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2016-05-15 17:37:00
On Site Datetime
2016-05-15 18:17:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
5.0
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
1989.0
Pipe Diameter
2.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Unknown
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
1.9
Puncture Circum
1.9
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
136044.0
Est Cost Emergency
2601.0
Est Cost Other
0.0
Est Cost Unintentional Release
1074.0
Prpty
139719.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
24.0
Accident Psig
40.0
Normal Psig
40.0
Mop Psig
45.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Third Party That Caused The Incident
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
City Street
Excavator Type
County
Excavator Equipment
Backhoe/trackhoe
Work Performed
Sewer (Sanitary/storm)
One Call Notified Ind
No
Service Interruption
Yes
Service Interruption Hours
50.0
Root Cause Category
Notification Issue
Root Cause Type
No Notification Made To The One-Call Center/811
Preparer Name
R**** M*******
Preparer Title
Sr. Compliance Engineer
Preparer Email
R*******@a***********.com
Preparer Telephone
(404) 584-3733
Preparer Fax
(404) 584-4710
Authorizer Name
R****** R L***
Authorizer Title
Managing Director Compliance And Prm
Authorizer Telephone
(404) 584-3552
Authorizer Email
R****@a***********.com
Narrative
A 2-inch plastic main with one-way feed was ruptured by a county water & sewer crew while performing maintenance work. Once the incident was made safe it was identified that mud, water and debris had entered the downstream gas pipeline where crews began running a cleaning pig to clean the pipeline where it was determined that satisfactory results were not being obtained. At this point during evaluations it was determined that the affected pipeline should be replaced where cost of replacement was the direct results of the incident and not improvements to the existing system where the additional cost resulted in the incident exceeding the $50,000 threshold for reporting. Notification of excavation by the excavator was not made to the one-call center before damage occurred.
| Occurred At | 2016-05-15 17:37:00 |
|---|---|
| Year | 2016 |
| Report Received Date | 2016-05-27 00:00:00 |
| Iyear | 2016.0 |
| Report Number | 20160049.0 |
| Supplemental Number | 16307.0 |
| Report Type | Original Final |
| Operator Id | 792 PHMSA Enforcement |
| Name | Atlanta Gas Light Co |
| Operator Street Address | 10 Peachtree Place Ne |
| Operator City Name | Atlanta |
| Operator State Abbreviation | GA |
| Operator Postal Code | 30309 |
| Local Datetime | 2016-05-15 17:37:00 |
| Location Street Address | 1120 Mcconnell Drive |
| Location City Name | Decatur |
| Location County Name | Dekalb |
| Location State Abbreviation | GA |
| Location Postal Code | 30033 |
| Location Latitude | 33.811634 Google Maps OpenStreetMap |
| Location Longitude | -84.312419 Google Maps OpenStreetMap |
| Nrc Rpt Datetime | 2016-05-16 18:01:00 |
| Nrc Rpt Num | 1147911 NRC Report How to search |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 560.04 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2016-05-15 17:37:00 |
| On Site Datetime | 2016-05-15 18:17:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Exposed Due To Excavation |
| Depth Of Cover | 5.0 |
| Crossing | No |
| Pipe Facility Type | Privately Owned |
| System Part Involved | Main |
| Installation Year | 1989.0 |
| Pipe Diameter | 2.0 |
| Pipe Specification | Astm D2513 |
| Pipe Manufacturer | Unknown |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Plastic Sdr | 11 |
| Material Pe Pipe Code | 2406 |
| Release Type | Mechanical Puncture |
| Puncture Axial | 1.9 |
| Puncture Circum | 1.9 |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 0.0 |
| Est Cost Prop Damage | 136044.0 |
| Est Cost Emergency | 2601.0 |
| Est Cost Other | 0.0 |
| Est Cost Unintentional Release | 1074.0 |
| Prpty | 139719.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 24.0 |
| Accident Psig | 40.0 |
| Normal Psig | 40.0 |
| Mop Psig | 45.0 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Third Party That Caused The Incident |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | No |
| Notify Cga Dirt | Yes |
| Public Row Ind | Yes |
| Public Subtype | City Street |
| Excavator Type | County |
| Excavator Equipment | Backhoe/trackhoe |
| Work Performed | Sewer (Sanitary/storm) |
| One Call Notified Ind | No |
| Service Interruption | Yes |
| Service Interruption Hours | 50.0 |
| Root Cause Category | Notification Issue |
| Root Cause Type | No Notification Made To The One-Call Center/811 |
| Preparer Name | R**** M******* |
| Preparer Title | Sr. Compliance Engineer |
| Preparer Email | R*******@a***********.com |
| Preparer Telephone | (404) 584-3733 |
| Preparer Fax | (404) 584-4710 |
| Authorizer Name | R****** R L*** |
| Authorizer Title | Managing Director Compliance And Prm |
| Authorizer Telephone | (404) 584-3552 |
| Authorizer Email | R****@a***********.com |
| Narrative | A 2-inch plastic main with one-way feed was ruptured by a county water & sewer crew while performing maintenance work. Once the incident was made safe it was identified that mud, water and debris had entered the downstream gas pipeline where crews began running a cleaning pig to clean the pipeline where it was determined that satisfactory results were not being obtained. At this point during evaluations it was determined that the affected pipeline should be replaced where cost of replacement was the direct results of the incident and not improvements to the existing system where the additional cost resulted in the incident exceeding the $50,000 threshold for reporting. Notification of excavation by the excavator was not made to the one-call center before damage occurred. |