Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2016-02-24 — TX
Operator
Texas Eastern Transmission, Lp (Spectra Energy Partners, Lp)
Cause
Material Failure Of Pipe Or Weld
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$109,360
Incident datetime
2016-02-24 09:12
Report number
Location
TX
Narrative
A spectra energy employee discovered bubbles in ponding water over texas eastern transmission, lp 36-inch line 25 near tremont, mississippi in itawamba county on february 24, 2016. The pipeline was excavated and a pinhole leak in the dsaw long seam weld was observed. Metallurgical analysis was performed, and the leak was the result of a pinhole leak with a diameter of approximately 0.043'. The pinhole was due to porosity in the seam weld. The pipe had been hydrostatic tested in 1965 to 1,378 psig (1.47 x maop) with no leak detected.
Detailed record list
Report Received Date
2016-03-16 00:00:00
Iyear
2016
Report Number
20160021
Supplemental Number
17436
Report Type
Supplemental Final
Operator Id
19235
Name
Texas Eastern Transmission, Lp (Spectra Energy Partners, Lp)
Operator Street Address
915 North Eldridge Parkway
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Local Datetime
2016-02-24 09:12:00
Location Latitude
34.3438291
Location Longitude
-88.2303334
Nrc Rpt Num
1141243
Nrc Rpt Datetime
2016-02-24 10:34:00
Commodity Released Type
Natural Gas
Unintentional Release
32
Intentional Release
23229
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2016-02-24 10:46:00
Restart Datetime
2016-03-01 09:48:00
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Incident Identified Datetime
2016-02-24 09:12:00
On Site Datetime
2016-02-24 09:12:00
On Off Shore
Onshore
Onshore State Abbreviation
Ms
Onshore Postal Code
38876
Onshore City Name
Not Within A Municipality
Onshore County Name
Itawamba
Designated Location
Milepost
Designated Name
121
Pipe Fac Name
36-Inch Line 25
Segment Name
Egypt-Barton
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
36
Pipe Wall Thickness
0.39
Pipe Smys
60000
Pipe Specification
Api-5l
Pipe Seam Type
Dsaw
Pipe Manufacturer
Kaiser Steel
Pipe Coating Type
Coal Tar
Installation Year
1965
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
760
Heat Damage Ind
No
Non Heat Damage Ind
No
Hca Fatalities Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
64
Est Cost Intentional Release
46458
Est Cost Prop Damage
109360
Est Cost Emergency
0
Est Cost Other
0
Prpty
155882
Accident Psig
843
Mop Psig
936
Mop Cfr Section
192.619(A)(1)
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
47995
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The leak resulted from a pinhole leak which could not be discovered by control instruments.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Design-, Construction-, Installation-, Or Fabrication-Related
Pwjf Failure Type
Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind
Yes
Other Factor
Yes
Other Factor Details
Porosity In Seam Weld
Pwf Additional Other Ind
Yes
Additional Other Details
Porosity In Seam Weld.
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2009
Geometry Recent Year
2009
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
D***** T**********
Preparer Title
Senior Technical Advisor
Preparer Email
D************@s************.com
Preparer Telephone
713-627-5573
Authorizer Name
N***** A****
Authorizer Title
Manager
Authorizer Telephone
713-627-5008
Authorizer Email
N******@s************.com
Narrative
A spectra energy employee discovered bubbles in ponding water over texas eastern transmission, lp 36-inch line 25 near tremont, mississippi in itawamba county on february 24, 2016. The pipeline was excavated and a pinhole leak in the dsaw long seam weld was observed. Metallurgical analysis was performed, and the leak was the result of a pinhole leak with a diameter of approximately 0.043'. The pinhole was due to porosity in the seam weld. The pipe had been hydrostatic tested in 1965 to 1,378 psig (1.47 x maop) with no leak detected.
| Report Received Date | 2016-03-16 00:00:00 |
|---|---|
| Iyear | 2016 |
| Report Number | 20160021 |
| Supplemental Number | 17436 |
| Report Type | Supplemental Final |
| Operator Id | 19235 PHMSA Enforcement |
| Name | Texas Eastern Transmission, Lp (Spectra Energy Partners, Lp) |
| Operator Street Address | 915 North Eldridge Parkway |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77079 |
| Local Datetime | 2016-02-24 09:12:00 |
| Location Latitude | 34.3438291 Google Maps OpenStreetMap |
| Location Longitude | -88.2303334 Google Maps OpenStreetMap |
| Nrc Rpt Num | 1141243 NRC Report How to search |
| Nrc Rpt Datetime | 2016-02-24 10:34:00 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 32 |
| Intentional Release | 23229 |
| Accompanying Liquid | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2016-02-24 10:46:00 |
| Restart Datetime | 2016-03-01 09:48:00 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Incident Identified Datetime | 2016-02-24 09:12:00 |
| On Site Datetime | 2016-02-24 09:12:00 |
| On Off Shore | Onshore |
| Onshore State Abbreviation | Ms |
| Onshore Postal Code | 38876 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Itawamba |
| Designated Location | Milepost |
| Designated Name | 121 |
| Pipe Fac Name | 36-Inch Line 25 |
| Segment Name | Egypt-Barton |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 36 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| Item Involved | Pipe |
| Pipe Type | Pipe Seam |
| Pipe Diameter | 36 |
| Pipe Wall Thickness | 0.39 |
| Pipe Smys | 60000 |
| Pipe Specification | Api-5l |
| Pipe Seam Type | Dsaw |
| Pipe Manufacturer | Kaiser Steel |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1965 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Class Location Type | Class 1 Location |
| Could Be Hca | No |
| Pir Radius | 760 |
| Heat Damage Ind | No |
| Non Heat Damage Ind | No |
| Hca Fatalities Ind | No |
| Est Cost Oper Paid | 0 |
| Est Cost Unintentional Release | 64 |
| Est Cost Intentional Release | 46458 |
| Est Cost Prop Damage | 109360 |
| Est Cost Emergency | 0 |
| Est Cost Other | 0 |
| Prpty | 155882 |
| Accident Psig | 843 |
| Mop Psig | 936 |
| Mop Cfr Section | 192.619(A)(1) View CFR 49 §192 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Pressure Restriction Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Length Segment Isolated | 47995 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | Transmission System |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Accident Identifier | Ground Patrol By Operator Or Its Contractor |
| Operator Type | Operator Employee |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The leak resulted from a pinhole leak which could not be discovered by control instruments. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Material Failure Of Pipe Or Weld |
| Cause Details | Design-, Construction-, Installation-, Or Fabrication-Related |
| Pwjf Failure Type | Design-, Construction-, Installation-, Or Fabrication-Related |
| Field Exam Ind | Yes |
| Other Factor | Yes |
| Other Factor Details | Porosity In Seam Weld |
| Pwf Additional Other Ind | Yes |
| Additional Other Details | Porosity In Seam Weld. |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Geometry Deformation Ind | Yes |
| Axial Recent Year | 2009 |
| Geometry Recent Year | 2009 |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | D***** T********** |
| Preparer Title | Senior Technical Advisor |
| Preparer Email | D************@s************.com |
| Preparer Telephone | 713-627-5573 |
| Authorizer Name | N***** A**** |
| Authorizer Title | Manager |
| Authorizer Telephone | 713-627-5008 |
| Authorizer Email | N******@s************.com |
| Narrative | A spectra energy employee discovered bubbles in ponding water over texas eastern transmission, lp 36-inch line 25 near tremont, mississippi in itawamba county on february 24, 2016. The pipeline was excavated and a pinhole leak in the dsaw long seam weld was observed. Metallurgical analysis was performed, and the leak was the result of a pinhole leak with a diameter of approximately 0.043'. The pinhole was due to porosity in the seam weld. The pipe had been hydrostatic tested in 1965 to 1,378 psig (1.47 x maop) with no leak detected. |