Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2015-11-18 — TX
Operator
Sunoco Pipeline L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$10,000
Incident datetime
2015-11-18 08:00
Report number
Location
TX
Narrative
At approximately 08:00 on 11/18/2015, a company employee discovered an approximate 2 bbl release of crude oil inside alvord pump station. The pump station was down and isolated from the mainline prior to the discovery of the release. The employee that discovered the release was onsite to perform a station review and assessment and did not have response materials and equipment available. The area manager was immediately alerted and additional personnel and resources were dispatched to the site arriving at approximately 09:15 as cleanup efforts progressed it was discovered that aproximately 10 gallons of crude oil had migrated to a small pond adjacent to the facility due to heavy rain the night before. At this time additional internal notifications were made and the release was reported to the nrc. The oil/water mix was immediately removed from the pond via vacuum truck. All contaminated soil was excavated and remediated onsite. Investigation of the failed section revealed an internal corrosion pinhole in the discharge piping from the pump and a plidco clamp was installwd. This pump station is no longer utilized for normal operation of the pipeline and as such the affected pipe and other station piping will remain isolated and bypassed from the mainline. Modifications are planned that will remove the underground station piping and bring all above grade. The failed section of pipe will be permanently removed via this project.
Detailed record list
Report Received Date
2015-12-15 00:00:00
Iyear
2015
Report Number
20150460
Supplemental Number
21092
Report Type
Supplemental Final
Operator Id
18718
Name
Sunoco Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2015-11-18 08:00:00
Location Latitude
33.34157
Location Longitude
-97.6054
Commodity Released Type
Crude Oil
Unintentional Release Bbls
2
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2015-11-18 08:00:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Sttion Was Already Isolated From The Mainline.
On Site Datetime
2015-11-18 09:15:00
Nrc Rpt Datetime
2015-11-18 13:35:00
Nrc Rpt Num
1131751
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Alvord Station
Segment Name
22002-16" Ringgold To Corsicana
Onshore State Abbreviation
Tx
Onshore Postal Code
76225
Onshore City Name
Alvord
Onshore County Name
Wise
Designated Location
Milepost/valve Station
Designated Name
41.4
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
60
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
16
Pipe Wall Thickness
0.312
Pipe Smys
42000
Pipe Specification
Api 5l
Pipe Seam Type
Erw � Unknown Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Fusion Bonded Epoxy(Fbe)
Installation Year
1980
Manufactured Year
1980
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Surface Water Remed Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
0.24
Rel Water Name
Unnamed Pond Adjacent To Station Property.
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
500
Est Cost Gas Released
84
Est Cost Prop Damage
10000
Est Cost Emergency
25000
Est Cost Environmental
9300
Est Cost Other
0
Prpty
44884
Accident Psig
100
Mop Psig
776
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Microbiological Ind
Yes
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
No
Corrosion Lining
No
Cleaning Dewatering
Not Applicable - Not Mainline Pipe
Corrosion Coupons
Not Applicable - Not Mainline Pipe
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
T*** G* N*******
Preparer Title
Dot Compliance Manager
Preparer Email
T*********@s**************.com
Preparer Telephone
281-637-6576
Preparer Fax
877-917-0448
Prepared Date
2016-02-04 00:00:00
Authorizer Name
T*** G* N*******
Authorizer Telephone
281-637-6576
Authorizer Title
Dot Compliance Manager
Authorizer Email
T*********@s**************.com
Narrative
At approximately 08:00 on 11/18/2015, a company employee discovered an approximate 2 bbl release of crude oil inside alvord pump station. The pump station was down and isolated from the mainline prior to the discovery of the release. The employee that discovered the release was onsite to perform a station review and assessment and did not have response materials and equipment available. The area manager was immediately alerted and additional personnel and resources were dispatched to the site arriving at approximately 09:15 as cleanup efforts progressed it was discovered that aproximately 10 gallons of crude oil had migrated to a small pond adjacent to the facility due to heavy rain the night before. At this time additional internal notifications were made and the release was reported to the nrc. The oil/water mix was immediately removed from the pond via vacuum truck. All contaminated soil was excavated and remediated onsite. Investigation of the failed section revealed an internal corrosion pinhole in the discharge piping from the pump and a plidco clamp was installwd. This pump station is no longer utilized for normal operation of the pipeline and as such the affected pipe and other station piping will remain isolated and bypassed from the mainline. Modifications are planned that will remove the underground station piping and bring all above grade. The failed section of pipe will be permanently removed via this project.
| Report Received Date | 2015-12-15 00:00:00 |
|---|---|
| Iyear | 2015 |
| Report Number | 20150460 |
| Supplemental Number | 21092 |
| Report Type | Supplemental Final |
| Operator Id | 18718 PHMSA Enforcement |
| Name | Sunoco Pipeline L.p. |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2015-11-18 08:00:00 |
| Location Latitude | 33.34157 Google Maps OpenStreetMap |
| Location Longitude | -97.6054 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 2 |
| Recovered Bbls | 1 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2015-11-18 08:00:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Sttion Was Already Isolated From The Mainline. |
| On Site Datetime | 2015-11-18 09:15:00 |
| Nrc Rpt Datetime | 2015-11-18 13:35:00 |
| Nrc Rpt Num | 1131751 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Alvord Station |
| Segment Name | 22002-16" Ringgold To Corsicana |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 76225 |
| Onshore City Name | Alvord |
| Onshore County Name | Wise |
| Designated Location | Milepost/valve Station |
| Designated Name | 41.4 |
| Federal | No |
| Location Type | Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 60 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 16 |
| Pipe Wall Thickness | 0.312 |
| Pipe Smys | 42000 |
| Pipe Specification | Api 5l |
| Pipe Seam Type | Erw � Unknown Frequency |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Fusion Bonded Epoxy(Fbe) |
| Installation Year | 1980 |
| Manufactured Year | 1980 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Surface Water Remed Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | Yes |
| Surface Contam Ind | Yes |
| Amount Released | 0.24 |
| Rel Water Name | Unnamed Pond Adjacent To Station Property. |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 500 |
| Est Cost Gas Released | 84 |
| Est Cost Prop Damage | 10000 |
| Est Cost Emergency | 25000 |
| Est Cost Environmental | 9300 |
| Est Cost Other | 0 |
| Prpty | 44884 |
| Accident Psig | 100 |
| Mop Psig | 776 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | A review of the accident determined that there were no control room actions that contributed to the event. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Localized Pitting |
| Int Microbiological Ind | Yes |
| Int Field Exam Basis Ind | Yes |
| Int Low Point Pipe Loc Ind | Yes |
| Corrosion Inhibitors | No |
| Corrosion Lining | No |
| Cleaning Dewatering | Not Applicable - Not Mainline Pipe |
| Corrosion Coupons | Not Applicable - Not Mainline Pipe |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | T*** G* N******* |
| Preparer Title | Dot Compliance Manager |
| Preparer Email | T*********@s**************.com |
| Preparer Telephone | 281-637-6576 |
| Preparer Fax | 877-917-0448 |
| Prepared Date | 2016-02-04 00:00:00 |
| Authorizer Name | T*** G* N******* |
| Authorizer Telephone | 281-637-6576 |
| Authorizer Title | Dot Compliance Manager |
| Authorizer Email | T*********@s**************.com |
| Narrative | At approximately 08:00 on 11/18/2015, a company employee discovered an approximate 2 bbl release of crude oil inside alvord pump station. The pump station was down and isolated from the mainline prior to the discovery of the release. The employee that discovered the release was onsite to perform a station review and assessment and did not have response materials and equipment available. The area manager was immediately alerted and additional personnel and resources were dispatched to the site arriving at approximately 09:15 as cleanup efforts progressed it was discovered that aproximately 10 gallons of crude oil had migrated to a small pond adjacent to the facility due to heavy rain the night before. At this time additional internal notifications were made and the release was reported to the nrc. The oil/water mix was immediately removed from the pond via vacuum truck. All contaminated soil was excavated and remediated onsite. Investigation of the failed section revealed an internal corrosion pinhole in the discharge piping from the pump and a plidco clamp was installwd. This pump station is no longer utilized for normal operation of the pipeline and as such the affected pipe and other station piping will remain isolated and bypassed from the mainline. Modifications are planned that will remove the underground station piping and bring all above grade. The failed section of pipe will be permanently removed via this project. |