HL incident on 2015-10-15 — TX

Operator
Nustar Logistics, L.p.
Cause
Material Failure Of Pipe Or Weld
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$42,525
Incident datetime
2015-10-15 16:25
Report number
Location
TX
Narrative
While performing a dig to repair an anomaly discovered on an in-line inspection assessment, a nustar maintenance employee noticed a hydrocarbon odor coming from the soil. Upon investigation, a pinhole leak was discovered. A type-b sleeve was installed to repair the leak. The failed segment of pipe will be removed and examined to determine the cause of the failure. Update- the leak occurred in a portion of the longitudinal seam which was malformed. Misalignment of the seam during the manufacturing process contributed to the malformation.
Detailed record list
Report Received Date
2015-11-12 00:00:00
Iyear
2015
Report Number
20150401
Supplemental Number
21463
Report Type
Supplemental Final
Operator Id
Name
Nustar Logistics, L.p.
Operator Street Address
8111 Westchester Drive
Operator City Name
Dallas
Operator State Abbreviation
TX
Operator Postal Code
75225
Local Datetime
2015-10-15 16:25:00
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
0.41
Recovered Bbls
0.41
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2015-10-15 16:25:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2015-10-15 16:35:00
Restart Datetime
2015-10-16 17:49:00
On Site Datetime
2015-10-15 16:25:00
Nrc Rpt Datetime
2015-10-15 17:43:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
05p Southlake Pipeline
Segment Name
Davidson - Sheppard
Onshore State Abbreviation
Tx
Onshore Postal Code
76360
Onshore City Name
Not Within A Municipality
Onshore County Name
Wichita
Designated Location
Survey Station No.
Designated Name
11799+15
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
8.625
Pipe Wall Thickness
0.188
Pipe Smys
46000
Pipe Specification
Api 5l
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Kaiser
Pipe Coating Type
Cold Applied Tape
Installation Year
1979
Manufactured Year
1979
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
35
Est Cost Prop Damage
42525
Est Cost Emergency
1285
Est Cost Environmental
0
Est Cost Other
3739
Est Cost Other Details
Estimated Other Costs Include Metallurgical Analysis/failure Investigation
Prpty
47584
Accident Psig
328
Mop Psig
1252
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
73439
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Controller actions were not a cause or contributing factor to the accident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind
Yes
Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor
Yes
Other Factor Details
Original Manufacturing Defect
Pwf Addl Misalignment Ind
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Cir Trn Wave Mgn Flx Lkg Ind
Yes
Axial Recent Year
2012
Circ Wave Recent Year
2015
Geometry Recent Year
2012
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
R****** P****
Preparer Title
Lead Pipeline Safety Specialist
Preparer Email
R************@n***********.com
Preparer Telephone
361-249-9417
Preparer Fax
210-918-7117
Prepared Date
2016-06-24 00:00:00
Authorizer Name
W** G***
Authorizer Telephone
361-249-9402
Authorizer Title
Vice President And General Manager
Authorizer Email
W*******@n***********.com
Narrative
While performing a dig to repair an anomaly discovered on an in-line inspection assessment, a nustar maintenance employee noticed a hydrocarbon odor coming from the soil. Upon investigation, a pinhole leak was discovered. A type-b sleeve was installed to repair the leak. The failed segment of pipe will be removed and examined to determine the cause of the failure. Update- the leak occurred in a portion of the longitudinal seam which was malformed. Misalignment of the seam during the manufacturing process contributed to the malformation.
Report Received Date 2015-11-12 00:00:00
Iyear 2015
Report Number 20150401
Supplemental Number 21463
Report Type Supplemental Final
Operator Id 31454 PHMSA Enforcement
Name Nustar Logistics, L.p.
Operator Street Address 8111 Westchester Drive
Operator City Name Dallas
Operator State Abbreviation TX
Operator Postal Code 75225
Local Datetime 2015-10-15 16:25:00
Location Latitude 34.105033 Google Maps OpenStreetMap
Location Longitude -98.84851 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls 0.41
Recovered Bbls 0.41
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2015-10-15 16:25:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2015-10-15 16:35:00
Restart Datetime 2015-10-16 17:49:00
On Site Datetime 2015-10-15 16:25:00
Nrc Rpt Datetime 2015-10-15 17:43:00
Nrc Rpt Num 1130959 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name 05p Southlake Pipeline
Segment Name Davidson - Sheppard
Onshore State Abbreviation Tx
Onshore Postal Code 76360
Onshore City Name Not Within A Municipality
Onshore County Name Wichita
Designated Location Survey Station No.
Designated Name 11799+15
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 48
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 8.625
Pipe Wall Thickness 0.188
Pipe Smys 46000
Pipe Specification Api 5l
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Kaiser
Pipe Coating Type Cold Applied Tape
Installation Year 1979
Manufactured Year 1979
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 35
Est Cost Prop Damage 42525
Est Cost Emergency 1285
Est Cost Environmental 0
Est Cost Other 3739
Est Cost Other Details Estimated Other Costs Include Metallurgical Analysis/failure Investigation
Prpty 47584
Accident Psig 328
Mop Psig 1252
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 73439
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Controller actions were not a cause or contributing factor to the accident.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind Yes
Failure Type Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor Yes
Other Factor Details Original Manufacturing Defect
Pwf Addl Misalignment Ind Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Cir Trn Wave Mgn Flx Lkg Ind Yes
Axial Recent Year 2012
Circ Wave Recent Year 2015
Geometry Recent Year 2012
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name R****** P****
Preparer Title Lead Pipeline Safety Specialist
Preparer Email R************@n***********.com
Preparer Telephone 361-249-9417
Preparer Fax 210-918-7117
Prepared Date 2016-06-24 00:00:00
Authorizer Name W** G***
Authorizer Telephone 361-249-9402
Authorizer Title Vice President And General Manager
Authorizer Email W*******@n***********.com
Narrative While performing a dig to repair an anomaly discovered on an in-line inspection assessment, a nustar maintenance employee noticed a hydrocarbon odor coming from the soil. Upon investigation, a pinhole leak was discovered. A type-b sleeve was installed to repair the leak. The failed segment of pipe will be removed and examined to determine the cause of the failure. Update- the leak occurred in a portion of the longitudinal seam which was malformed. Misalignment of the seam during the manufacturing process contributed to the malformation.

All rights reserved. Copyright © by ClearPHMSA