Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2015-10-12 — TX
Operator
Kinder Morgan Wink Pipeline Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$12,000
Incident datetime
2015-10-12 11:09
Report number
Location
TX
Narrative
The aerial patrol pilot notified the control center on 10/12/15 of a possible crude oil leak near kinder morgan's mason station. The controller shutdown the pipeline, and field operations investigated the site. A release was discovered on the 20" wink to guadalupe pipeline, 0.5 miles east of mason station at milepost 159. An engineered leak clamp was applied to the pipeline to mitigate the release while the pipeline was shutdown. A b-sleeve was installed as a permanent repair. The pipeline was shutdown longer than anticipated due to a directive from the receiving refinery, which was not related to the kinder morgan pipeline release.
Detailed record list
Report Received Date
2015-11-11 00:00:00
Iyear
2015
Report Number
20150399
Supplemental Number
20893
Report Type
Original
Operator Id
31957
Name
Kinder Morgan Wink Pipeline Llc
Operator Street Address
1001 Louisiana St, Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2015-10-12 11:30:00
Location Latitude
31.80148
Location Longitude
-103.79509
Commodity Released Type
Crude Oil
Unintentional Release Bbls
17
Recovered Bbls
9
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Air Patrol
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2015-10-12 11:09:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2015-10-12 11:09:00
Restart Datetime
2015-10-14 15:20:00
On Site Datetime
2015-10-12 11:30:00
Nrc Rpt Datetime
2015-10-12 12:22:00
Nrc Rpt Num
1130673
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Automatic
Downstream Valve Type Ind
Automatic
Num Pub Evacuated
0
Pipe Fac Name
20" Wink To El Paso
Segment Name
20" Wink To Guadalupe
Onshore State Abbreviation
Tx
Onshore Postal Code
79770
Onshore City Name
Orla
Onshore County Name
Loving
Designated Location
Milepost/valve Station
Designated Name
Mp 159
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
30
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
20
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
X-52
Pipe Seam Type
Erw - Low Frequency
Pipe Manufacturer
Ygstn
Pipe Coating Type
Coal Tar
Installation Year
1955
Manufactured Year
1955
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
792
Est Cost Prop Damage
12000
Est Cost Emergency
0
Est Cost Environmental
162000
Est Cost Other
0
Prpty
174792
Accident Psig
158
Mop Psig
526
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
21648
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Schedule Ind
Yes
Invest No Schedule Ind Details
The Cause Of The Incident Was Not Related To Controller Actions. The Controller Responded Appropriately To The Leak Report, And Did Not Contribute To The Accident.
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Microbiological Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
2004
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2015
Close Interval Survey Year
2012
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Ultrasonic Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2008
Ultrasonic Recent Year
2013
Geometry Recent Year
2013
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1983
Hydrtst Most Rcnt Pressure
650
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
A**** Z*****
Preparer Title
Manager-Regulatory Compliance
Preparer Email
A***********@k***********.com
Preparer Telephone
713-369-9512
Preparer Fax
303-984-3417
Prepared Date
2015-11-11 00:00:00
Authorizer Name
K****** H H***** J*
Authorizer Telephone
713-369-9113
Authorizer Title
Vice President-Source And Transportation
Authorizer Email
K*********@k***********.com
Narrative
The aerial patrol pilot notified the control center on 10/12/15 of a possible crude oil leak near kinder morgan's mason station. The controller shutdown the pipeline, and field operations investigated the site. A release was discovered on the 20" wink to guadalupe pipeline, 0.5 miles east of mason station at milepost 159. An engineered leak clamp was applied to the pipeline to mitigate the release while the pipeline was shutdown. A b-sleeve was installed as a permanent repair. The pipeline was shutdown longer than anticipated due to a directive from the receiving refinery, which was not related to the kinder morgan pipeline release.
| Report Received Date | 2015-11-11 00:00:00 |
|---|---|
| Iyear | 2015 |
| Report Number | 20150399 |
| Supplemental Number | 20893 |
| Report Type | Original |
| Operator Id | 31957 PHMSA Enforcement |
| Name | Kinder Morgan Wink Pipeline Llc |
| Operator Street Address | 1001 Louisiana St, Suite 1000 |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2015-10-12 11:30:00 |
| Location Latitude | 31.80148 Google Maps OpenStreetMap |
| Location Longitude | -103.79509 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 17 |
| Recovered Bbls | 9 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Air Patrol |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2015-10-12 11:09:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2015-10-12 11:09:00 |
| Restart Datetime | 2015-10-14 15:20:00 |
| On Site Datetime | 2015-10-12 11:30:00 |
| Nrc Rpt Datetime | 2015-10-12 12:22:00 |
| Nrc Rpt Num | 1130673 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Automatic |
| Downstream Valve Type Ind | Automatic |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | 20" Wink To El Paso |
| Segment Name | 20" Wink To Guadalupe |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 79770 |
| Onshore City Name | Orla |
| Onshore County Name | Loving |
| Designated Location | Milepost/valve Station |
| Designated Name | Mp 159 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 30 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 20 |
| Pipe Wall Thickness | 0.25 |
| Pipe Smys | 52000 |
| Pipe Specification | X-52 |
| Pipe Seam Type | Erw - Low Frequency |
| Pipe Manufacturer | Ygstn |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1955 |
| Manufactured Year | 1955 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 792 |
| Est Cost Prop Damage | 12000 |
| Est Cost Emergency | 0 |
| Est Cost Environmental | 162000 |
| Est Cost Other | 0 |
| Prpty | 174792 |
| Accident Psig | 158 |
| Mop Psig | 526 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 21648 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest No Schedule Ind | Yes |
| Invest No Schedule Ind Details | The Cause Of The Incident Was Not Related To Controller Actions. The Controller Responded Appropriately To The Leak Report, And Did Not Contribute To The Accident. |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Galvanic Corrosion Ind | Yes |
| Microbiological Corrosion Ind | Yes |
| Field Exam Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | Yes |
| Cathodic Pro Start Year | 2004 |
| Shielding Evident | Yes |
| Cathodic Survey Type | Yes |
| Cp Annual Survey Ind | Yes |
| Close Interval Survey Ind | Yes |
| Cp Annual Survey Year | 2015 |
| Close Interval Survey Year | 2012 |
| Prior Damage | Yes |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Ultrasonic Ind | Yes |
| Geometry Deformation Ind | Yes |
| Axial Recent Year | 2008 |
| Ultrasonic Recent Year | 2013 |
| Geometry Recent Year | 2013 |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 1983 |
| Hydrtst Most Rcnt Pressure | 650 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | A**** Z***** |
| Preparer Title | Manager-Regulatory Compliance |
| Preparer Email | A***********@k***********.com |
| Preparer Telephone | 713-369-9512 |
| Preparer Fax | 303-984-3417 |
| Prepared Date | 2015-11-11 00:00:00 |
| Authorizer Name | K****** H H***** J* |
| Authorizer Telephone | 713-369-9113 |
| Authorizer Title | Vice President-Source And Transportation |
| Authorizer Email | K*********@k***********.com |
| Narrative | The aerial patrol pilot notified the control center on 10/12/15 of a possible crude oil leak near kinder morgan's mason station. The controller shutdown the pipeline, and field operations investigated the site. A release was discovered on the 20" wink to guadalupe pipeline, 0.5 miles east of mason station at milepost 159. An engineered leak clamp was applied to the pipeline to mitigate the release while the pipeline was shutdown. A b-sleeve was installed as a permanent repair. The pipeline was shutdown longer than anticipated due to a directive from the receiving refinery, which was not related to the kinder morgan pipeline release. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA