Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2015-04-16 — TX
Operator
Enterprise Products Operating Llc
Cause
Incorrect Operation
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2015-04-16 07:45
Report number
Location
TX
Narrative
On april 16, 2015 ' operations personnel and contract crew had blown down launching barrel on lid 914b-100 in order to load a cleaning pig. In order to purge the launching barrel with nitrogen of hazardous vapors and not to over pressure the barrel, a pressure relief valve set at 1000 psi was installed on the launching barrel. After the launching barrel was blown down and cleaning pig inserted, the maintenance crew started to re-pressure the launching barrel with product off of the line that was flowing and operating at around 1100 psi. When the pressure on the launching barrel exceeded 1000 psi, the relief valve started relieving to the atmosphere. The valve used to pressure the launching barrel was closed and the relief valve closed off. The 1000 psig relief valve should have been replaced by one set at 1440 psig. The accident and procedures was reviewed with all personnel involved.
Detailed record list
Report Received Date
2015-05-11 00:00:00
Iyear
2015
Report Number
20150171
Supplemental Number
20428
Report Type
Original Final
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2015-04-16 07:45:00
Location Latitude
29.57863
Location Longitude
-95.017273
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Rgp
Unintentional Release Bbls
2.3
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2015-04-16 07:45:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Relief Valve On Pig Trap Closed Manually.
On Site Datetime
2015-04-16 07:45:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Morgans Point To Texas Petro Olefins #3
Segment Name
914b-100
Onshore State Abbreviation
Tx
Onshore Postal Code
77209
Onshore City Name
Not Within A Municipality
Onshore County Name
Harris
Designated Location
Milepost/valve Station
Designated Name
Mp 12.98
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Valve
Valve Type
Relief Valve
Installation Year
2015
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Pressure Exceeded Temporary Relief Valve Pressure Setting Of 1000 Psi
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
100
Est Cost Prop Damage
0
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
100
Accident Psig
1100
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
15
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Controllers was aware of the maintenance activities on the pipeline but was not involved in causing the relief valve to release product.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Wrong Equipment Specified Or Installed
Operation Type
Wrong Equipment Specified Or Installed
Related Failure Follow Ind
Yes
Category Type
Routine Maintenance
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
N*** B******
Preparer Title
Sr. Pipeline Compliance Specialist
Preparer Email
W********@e****.com
Preparer Telephone
713-381-3536
Prepared Date
2015-05-11 00:00:00
Authorizer Name
N*** B******
Authorizer Telephone
713-381-3536
Authorizer Title
Sr. Pipeline Compliance Specialist
Authorizer Email
W********@e****.com
Narrative
On april 16, 2015 ' operations personnel and contract crew had blown down launching barrel on lid 914b-100 in order to load a cleaning pig. In order to purge the launching barrel with nitrogen of hazardous vapors and not to over pressure the barrel, a pressure relief valve set at 1000 psi was installed on the launching barrel. After the launching barrel was blown down and cleaning pig inserted, the maintenance crew started to re-pressure the launching barrel with product off of the line that was flowing and operating at around 1100 psi. When the pressure on the launching barrel exceeded 1000 psi, the relief valve started relieving to the atmosphere. The valve used to pressure the launching barrel was closed and the relief valve closed off. The 1000 psig relief valve should have been replaced by one set at 1440 psig. The accident and procedures was reviewed with all personnel involved.
| Report Received Date | 2015-05-11 00:00:00 |
|---|---|
| Iyear | 2015 |
| Report Number | 20150171 |
| Supplemental Number | 20428 |
| Report Type | Original Final |
| Operator Id | 31618 PHMSA Enforcement |
| Name | Enterprise Products Operating Llc |
| Operator Street Address | 1100 Louisiana Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2015-04-16 07:45:00 |
| Location Latitude | 29.57863 Google Maps OpenStreetMap |
| Location Longitude | -95.017273 Google Maps OpenStreetMap |
| Commodity Released Type | Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions |
| Commodity Subtype | Other Hvl |
| Commodity Details | Rgp |
| Unintentional Release Bbls | 2.3 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2015-04-16 07:45:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Relief Valve On Pig Trap Closed Manually. |
| On Site Datetime | 2015-04-16 07:45:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Morgans Point To Texas Petro Olefins #3 |
| Segment Name | 914b-100 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 77209 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Harris |
| Designated Location | Milepost/valve Station |
| Designated Name | Mp 12.98 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Valve |
| Valve Type | Relief Valve |
| Installation Year | 2015 |
| Material Involved | Carbon Steel |
| Release Type | Other |
| Release Type Details | Pressure Exceeded Temporary Relief Valve Pressure Setting Of 1000 Psi |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 100 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 0 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 100 |
| Accident Psig | 1100 |
| Mop Psig | 1440 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 15 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Controllers was aware of the maintenance activities on the pipeline but was not involved in causing the relief valve to release product. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Incorrect Operation |
| Cause Details | Wrong Equipment Specified Or Installed |
| Operation Type | Wrong Equipment Specified Or Installed |
| Related Failure Follow Ind | Yes |
| Category Type | Routine Maintenance |
| Operator Qualification Ind | Yes |
| Qualified Individuals | Yes, They Were Qualified For The Task(S) |
| Preparer Name | N*** B****** |
| Preparer Title | Sr. Pipeline Compliance Specialist |
| Preparer Email | W********@e****.com |
| Preparer Telephone | 713-381-3536 |
| Prepared Date | 2015-05-11 00:00:00 |
| Authorizer Name | N*** B****** |
| Authorizer Telephone | 713-381-3536 |
| Authorizer Title | Sr. Pipeline Compliance Specialist |
| Authorizer Email | W********@e****.com |
| Narrative | On april 16, 2015 ' operations personnel and contract crew had blown down launching barrel on lid 914b-100 in order to load a cleaning pig. In order to purge the launching barrel with nitrogen of hazardous vapors and not to over pressure the barrel, a pressure relief valve set at 1000 psi was installed on the launching barrel. After the launching barrel was blown down and cleaning pig inserted, the maintenance crew started to re-pressure the launching barrel with product off of the line that was flowing and operating at around 1100 psi. When the pressure on the launching barrel exceeded 1000 psi, the relief valve started relieving to the atmosphere. The valve used to pressure the launching barrel was closed and the relief valve closed off. The 1000 psig relief valve should have been replaced by one set at 1440 psig. The accident and procedures was reviewed with all personnel involved. |