Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2015-11-21 — NV
Operator
Paiute Pipeline Co
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$27,452
Incident datetime
2015-11-21 15:53
Report number
Location
NV
Narrative
On november 21, 2015, the 8-inch carson lateral was punctured on the south side of mica drive at US-395 during an in-line inspection (ili) tool run. The puncture occurred at a drop section containing 45-degree elbows installed in 1987 as part of a relocation for the construction of mica drive. An investigation on the cause of the incident has been completed and it was determined that during the ili of the carson lateral, the leading eye of the mfl tool struck the inside of the 45 degree elbow and caused a puncture in the pipeline. Company employees and contractors were stationed at the segment isolation valves as part of the ili procedure allowing for a rapid response and shutdown of the pipeline as part of the isolation plan. Public and private property damage includes six vehicles and a landscape retaining wall as a result of the blowing dirt and rocks. The magnetic flux leakage ili tool was also damaged.
Detailed record list
Report Received Date
2015-12-18 00:00:00
Iyear
2015
Report Number
20150150
Supplemental Number
17146
Report Type
Supplemental Final
Operator Id
15033
Name
Paiute Pipeline Co
Operator Street Address
5241 Spring Mountain Road
Operator City Name
Las Vegas
Operator State Abbreviation
NV
Operator Postal Code
89150
Local Datetime
2015-11-21 15:50:00
Location Latitude
39.09108
Location Longitude
-119.77467
Nrc Rpt Num
1134017
Nrc Rpt Datetime
2015-11-21 16:36:00
Commodity Released Type
Natural Gas
Unintentional Release
625
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2015-11-21 15:55:00
Restart Datetime
2015-11-25 10:27:00
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Incident Identified Datetime
2015-11-21 15:53:00
On Site Datetime
2015-11-21 15:53:00
On Off Shore
Onshore
Onshore State Abbreviation
Nv
Onshore Postal Code
89705
Onshore City Name
Carson City
Onshore County Name
Douglas
Designated Location
Milepost
Designated Name
Ca-57.30
Pipe Fac Name
Carson Lateral
Segment Name
Mica Drive Relocation
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
156
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased
Pipe Facility Type
Interstate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
8
Pipe Wall Thickness
0.188
Pipe Smys
42000
Pipe Specification
Api 5l
Pipe Seam Type
Longitudinal Erw - High Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Extruded Polyehylene
Installation Year
1987
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
1.4
Puncture Circum
0.6
Class Location Type
Class 3 Location
Could Be Hca
No
Pir Radius
126
Heat Damage Ind
No
Non Heat Damage Ind
No
Hca Fatalities Ind
No
Est Cost Oper Paid
400000
Est Cost Unintentional Release
1479
Est Cost Intentional Release
0
Est Cost Prop Damage
27452
Est Cost Emergency
962
Est Cost Other
0
Prpty
429893
Accident Psig
502
Mop Psig
520
Mop Cfr Section
192.619(A)(2)
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
33370
Internal Inspection Ind
Yes
Operation Complications Ind
Yes
Low Op Pressure Ind
Yes
Low Flow Ind
Yes
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A mechanical puncture occurred during an in-line inspection (ili) of the carson lateral. The punctured line was isolated from the parallel carson loop line. The scada information was limited to the carson loop due to the pipeline configuration as part of the ili procedure.
Employee Drug Test Ind
Yes
Contractor Drug Test Ind
Yes
Num Employees Tested
5
Num Employees Failed
0
Num Contractors Tested
2
Num Contractors Failed
0
Cause
Other Outside Force Damage
Cause Details
Other Outside Force Damage
Outside Force Type
Other Outside Force Damage
Osf Other Details
Paiute Pipeline Was Running An Inline Inspection Tool Through The Carson Lateral. The Leading Eye Of The Mfl Tool Struck The Inside Of A Long Radius 45 Degree Elbow, Puncturing The Pipe And Resulting In A Rupture.
Preparer Name
K***** C******
Preparer Title
Manager Of Engineering Paiute
Preparer Email
K*************@s****.com
Preparer Telephone
775-887-2814
Preparer Fax
775-882-4346
Authorizer Name
J*** M*****
Authorizer Title
Director Of Gas Operations Paiute
Authorizer Telephone
775-887-2805
Authorizer Email
J**********@s****.com
Narrative
On november 21, 2015, the 8-inch carson lateral was punctured on the south side of mica drive at US-395 during an in-line inspection (ili) tool run. The puncture occurred at a drop section containing 45-degree elbows installed in 1987 as part of a relocation for the construction of mica drive. An investigation on the cause of the incident has been completed and it was determined that during the ili of the carson lateral, the leading eye of the mfl tool struck the inside of the 45 degree elbow and caused a puncture in the pipeline. Company employees and contractors were stationed at the segment isolation valves as part of the ili procedure allowing for a rapid response and shutdown of the pipeline as part of the isolation plan. Public and private property damage includes six vehicles and a landscape retaining wall as a result of the blowing dirt and rocks. The magnetic flux leakage ili tool was also damaged.
| Report Received Date | 2015-12-18 00:00:00 |
|---|---|
| Iyear | 2015 |
| Report Number | 20150150 |
| Supplemental Number | 17146 |
| Report Type | Supplemental Final |
| Operator Id | 15033 PHMSA Enforcement |
| Name | Paiute Pipeline Co |
| Operator Street Address | 5241 Spring Mountain Road |
| Operator City Name | Las Vegas |
| Operator State Abbreviation | NV |
| Operator Postal Code | 89150 |
| Local Datetime | 2015-11-21 15:50:00 |
| Location Latitude | 39.09108 Google Maps OpenStreetMap |
| Location Longitude | -119.77467 Google Maps OpenStreetMap |
| Nrc Rpt Num | 1134017 NRC Report How to search |
| Nrc Rpt Datetime | 2015-11-21 16:36:00 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 625 |
| Intentional Release | 0 |
| Accompanying Liquid | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2015-11-21 15:55:00 |
| Restart Datetime | 2015-11-25 10:27:00 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Incident Identified Datetime | 2015-11-21 15:53:00 |
| On Site Datetime | 2015-11-21 15:53:00 |
| On Off Shore | Onshore |
| Onshore State Abbreviation | Nv |
| Onshore Postal Code | 89705 |
| Onshore City Name | Carson City |
| Onshore County Name | Douglas |
| Designated Location | Milepost |
| Designated Name | Ca-57.30 |
| Pipe Fac Name | Carson Lateral |
| Segment Name | Mica Drive Relocation |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 156 |
| Crossing | Yes |
| Road Crossing Ind | Yes |
| Road Type | Uncased |
| Pipe Facility Type | Interstate |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| Item Involved | Pipe |
| Pipe Type | Pipe Seam |
| Pipe Diameter | 8 |
| Pipe Wall Thickness | 0.188 |
| Pipe Smys | 42000 |
| Pipe Specification | Api 5l |
| Pipe Seam Type | Longitudinal Erw - High Frequency |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Extruded Polyehylene |
| Installation Year | 1987 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Mechanical Puncture |
| Puncture Axial | 1.4 |
| Puncture Circum | 0.6 |
| Class Location Type | Class 3 Location |
| Could Be Hca | No |
| Pir Radius | 126 |
| Heat Damage Ind | No |
| Non Heat Damage Ind | No |
| Hca Fatalities Ind | No |
| Est Cost Oper Paid | 400000 |
| Est Cost Unintentional Release | 1479 |
| Est Cost Intentional Release | 0 |
| Est Cost Prop Damage | 27452 |
| Est Cost Emergency | 962 |
| Est Cost Other | 0 |
| Prpty | 429893 |
| Accident Psig | 502 |
| Mop Psig | 520 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Pressure Restriction Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Length Segment Isolated | 33370 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | Yes |
| Low Op Pressure Ind | Yes |
| Low Flow Ind | Yes |
| Pipeline Function | Transmission System |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | A mechanical puncture occurred during an in-line inspection (ili) of the carson lateral. The punctured line was isolated from the parallel carson loop line. The scada information was limited to the carson loop due to the pipeline configuration as part of the ili procedure. |
| Employee Drug Test Ind | Yes |
| Contractor Drug Test Ind | Yes |
| Num Employees Tested | 5 |
| Num Employees Failed | 0 |
| Num Contractors Tested | 2 |
| Num Contractors Failed | 0 |
| Cause | Other Outside Force Damage |
| Cause Details | Other Outside Force Damage |
| Outside Force Type | Other Outside Force Damage |
| Osf Other Details | Paiute Pipeline Was Running An Inline Inspection Tool Through The Carson Lateral. The Leading Eye Of The Mfl Tool Struck The Inside Of A Long Radius 45 Degree Elbow, Puncturing The Pipe And Resulting In A Rupture. |
| Preparer Name | K***** C****** |
| Preparer Title | Manager Of Engineering Paiute |
| Preparer Email | K*************@s****.com |
| Preparer Telephone | 775-887-2814 |
| Preparer Fax | 775-882-4346 |
| Authorizer Name | J*** M***** |
| Authorizer Title | Director Of Gas Operations Paiute |
| Authorizer Telephone | 775-887-2805 |
| Authorizer Email | J**********@s****.com |
| Narrative | On november 21, 2015, the 8-inch carson lateral was punctured on the south side of mica drive at US-395 during an in-line inspection (ili) tool run. The puncture occurred at a drop section containing 45-degree elbows installed in 1987 as part of a relocation for the construction of mica drive. An investigation on the cause of the incident has been completed and it was determined that during the ili of the carson lateral, the leading eye of the mfl tool struck the inside of the 45 degree elbow and caused a puncture in the pipeline. Company employees and contractors were stationed at the segment isolation valves as part of the ili procedure allowing for a rapid response and shutdown of the pipeline as part of the isolation plan. Public and private property damage includes six vehicles and a landscape retaining wall as a result of the blowing dirt and rocks. The magnetic flux leakage ili tool was also damaged. |
External Resources