GTG incident on 2015-08-03 — TX

Operator
Tennessee Gas Pipeline Company
Cause
Material Failure Of Pipe Or Weld
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$40,601
Incident datetime
2015-08-03 20:36
Report number
Location
TX
Narrative
On 08/03/2015 at approximately 8:36pm tennessee gas pipeline (tgp) gas control received a pressure rate of change critical alarm on line 400-1. The gas controller contacted tgp operations to dispatch personnel to the possible leak site and take tgp station 1 offline. The controller also confirmed that local emergency responders, including the brooks county sheriffs department, were on-site. Operations initiated emergency response. The 400-1 line from mainline valve (mlv) 403-1 to mlv 404-1 was isolated at 10:06pm and the isolated section was blown down to a zero pressure by 10:15pm. The fire marshal evacuated homes and tx DOT temporarily closed hwy 285 for a 5 mile distance east and west until the isolated segment was blown down. The metallurgical report concluded that the cause was high ph stress corrosion cracking.
Detailed record list
Report Received Date
2015-09-02 00:00:00
Iyear
2015
Report Number
20150110
Supplemental Number
16929
Report Type
Supplemental Final
Operator Id
Name
Tennessee Gas Pipeline Company
Operator Street Address
1001 Louisiana St
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2015-08-03 20:36:00
Location Latitude
Location Longitude
Nrc Rpt Num
Nrc Rpt Datetime
2015-08-03 21:49:00
Commodity Released Type
Natural Gas
Unintentional Release
50740
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2015-08-03 22:06:00
Still Shutdown Ind
Yes
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
100
Incident Identified Datetime
2015-08-03 20:36:00
On Site Datetime
2015-08-03 21:30:00
On Off Shore
Onshore
Onshore State Abbreviation
Tx
Onshore Postal Code
78355
Onshore City Name
Falfurrias
Onshore County Name
Brooks
Designated Location
Milepost
Designated Name
403-1+51168
Pipe Fac Name
San Salvador (400-1)
Segment Name
Line 400-1
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
33
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
16
Pipe Wall Thickness
0.25
Pipe Smys
42000
Pipe Specification
Api 5l X42
Pipe Seam Type
Longitudinal Erw - Low Frequency
Pipe Manufacturer
Youngstown Sheet & Tube
Pipe Coating Type
Coal Tar
Installation Year
1947
Manufactured Year
1947
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Length
675
Rupture Width
16
Class Location Type
Class 2 Location
Could Be Hca
No
Pir Radius
332
Heat Damage Ind
No
Non Heat Damage Ind
No
Hca Fatalities Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
147585
Est Cost Intentional Release
0
Est Cost Prop Damage
40601
Est Cost Emergency
3312
Est Cost Other
0
Prpty
191498
Accident Psig
827
Mop Psig
903
Mop Cfr Section
192.619(A)(2)
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
58925
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The rupture was not related to controller actions and the controller notified tgp operations as soon as the incident was identified.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Environmental Cracking-Related
Pwjf Failure Type
Environmental Cracking-Related
Metallurgical Ind
Yes
Stress Subtype
Stress Corrosion Cracking
Pwf Additional Other Ind
Yes
Additional Other Details
Preexisting Oxide Inclusions And Seams/laps In The Steel
Collected Data Ind
Yes
Other Tool Tech Ind
Yes
Other Tool
Combination Tool
Other Recent Year
2009
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1997
Hydrtst Most Rcnt Pressure
1225
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
K****** V** D** L***
Preparer Title
Compliance Engineer Iii
Preparer Email
K*****************@k***********.com
Preparer Telephone
303-914-7753
Authorizer Name
R*** G*****
Authorizer Title
Director - Compliance Codes And Standards
Authorizer Telephone
713-420-5433
Authorizer Email
R**********@k***********.com
Narrative
On 08/03/2015 at approximately 8:36pm tennessee gas pipeline (tgp) gas control received a pressure rate of change critical alarm on line 400-1. The gas controller contacted tgp operations to dispatch personnel to the possible leak site and take tgp station 1 offline. The controller also confirmed that local emergency responders, including the brooks county sheriffs department, were on-site. Operations initiated emergency response. The 400-1 line from mainline valve (mlv) 403-1 to mlv 404-1 was isolated at 10:06pm and the isolated section was blown down to a zero pressure by 10:15pm. The fire marshal evacuated homes and tx DOT temporarily closed hwy 285 for a 5 mile distance east and west until the isolated segment was blown down. The metallurgical report concluded that the cause was high ph stress corrosion cracking.
Report Received Date 2015-09-02 00:00:00
Iyear 2015
Report Number 20150110
Supplemental Number 16929
Report Type Supplemental Final
Operator Id 19160 PHMSA Enforcement
Name Tennessee Gas Pipeline Company
Operator Street Address 1001 Louisiana St
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2015-08-03 20:36:00
Location Latitude 27.22217 Google Maps OpenStreetMap
Location Longitude -98.11031 Google Maps OpenStreetMap
Nrc Rpt Num 1124690 NRC Report How to search
Nrc Rpt Datetime 2015-08-03 21:49:00
Commodity Released Type Natural Gas
Unintentional Release 50740
Intentional Release 0
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Shutdown Due Accident Ind Yes
Shutdown Datetime 2015-08-03 22:06:00
Still Shutdown Ind Yes
Ignite Ind No
Explode Ind No
Num Pub Evacuated 100
Incident Identified Datetime 2015-08-03 20:36:00
On Site Datetime 2015-08-03 21:30:00
On Off Shore Onshore
Onshore State Abbreviation Tx
Onshore Postal Code 78355
Onshore City Name Falfurrias
Onshore County Name Brooks
Designated Location Milepost
Designated Name 403-1+51168
Pipe Fac Name San Salvador (400-1)
Segment Name Line 400-1
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 33
Crossing No
Pipe Facility Type Interstate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 16
Pipe Wall Thickness 0.25
Pipe Smys 42000
Pipe Specification Api 5l X42
Pipe Seam Type Longitudinal Erw - Low Frequency
Pipe Manufacturer Youngstown Sheet & Tube
Pipe Coating Type Coal Tar
Installation Year 1947
Manufactured Year 1947
Material Involved Carbon Steel
Release Type Rupture
Rupture Orient Longitudinal
Rupture Length 675
Rupture Width 16
Class Location Type Class 2 Location
Could Be Hca No
Pir Radius 332
Heat Damage Ind No
Non Heat Damage Ind No
Hca Fatalities Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 147585
Est Cost Intentional Release 0
Est Cost Prop Damage 40601
Est Cost Emergency 3312
Est Cost Other 0
Prpty 191498
Accident Psig 827
Mop Psig 903
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 58925
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Accident Identifier Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The rupture was not related to controller actions and the controller notified tgp operations as soon as the incident was identified.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Environmental Cracking-Related
Pwjf Failure Type Environmental Cracking-Related
Metallurgical Ind Yes
Stress Subtype Stress Corrosion Cracking
Pwf Additional Other Ind Yes
Additional Other Details Preexisting Oxide Inclusions And Seams/laps In The Steel
Collected Data Ind Yes
Other Tool Tech Ind Yes
Other Tool Combination Tool
Other Recent Year 2009
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1997
Hydrtst Most Rcnt Pressure 1225
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name K****** V** D** L***
Preparer Title Compliance Engineer Iii
Preparer Email K*****************@k***********.com
Preparer Telephone 303-914-7753
Authorizer Name R*** G*****
Authorizer Title Director - Compliance Codes And Standards
Authorizer Telephone 713-420-5433
Authorizer Email R**********@k***********.com
Narrative On 08/03/2015 at approximately 8:36pm tennessee gas pipeline (tgp) gas control received a pressure rate of change critical alarm on line 400-1. The gas controller contacted tgp operations to dispatch personnel to the possible leak site and take tgp station 1 offline. The controller also confirmed that local emergency responders, including the brooks county sheriffs department, were on-site. Operations initiated emergency response. The 400-1 line from mainline valve (mlv) 403-1 to mlv 404-1 was isolated at 10:06pm and the isolated section was blown down to a zero pressure by 10:15pm. The fire marshal evacuated homes and tx DOT temporarily closed hwy 285 for a 5 mile distance east and west until the isolated segment was blown down. The metallurgical report concluded that the cause was high ph stress corrosion cracking.

All rights reserved. Copyright © by ClearPHMSA