GD incident on 2014-12-20 — IN

Operator
Indiana Natural Gas Corp
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
1 fatality 0 injuries
Property damage (nominal)
$3,000
Incident datetime
2014-12-20 08:38
Report number
Location
IN, BARTHOLOMEW
Narrative
On saturday, december 20, 2014 a driver of a passenger vehicle lost control while driving west on a rural section of indiana state road 46 west, west of columbus, indiana. The vehicle was observed to fishtail on an ice covered bridge over wolf creek. It skidded off the north side of the highway while spinning 180-degrees and rolling over on its side. The vehicle came to rest on top of an above ground 1-inch 190 psi to 3/4-inch 20 psi service line/regulator assembly owned by indiana natural gas corporation. The force of the impact sheared the 1-inch gas line downstream of the shutoff valve for the farm tap, causing a gas leak. The gas did not ignite. Bartholomew county fire department emergency responders arrived on scene and found the sole occupant of the vehicle unresponsive and without a pulse. They were unable to immediately extricate the occupant from the vehicle due to his size. Noting a gas leak, they retreated, donned self-contained breathing apparatus and tried again unsuccessfully to remove the occupant from the vehicle. Emergency responders notified dispatch that they needed the local gas company to respond to the gas leak. Bartholomew county dispatch contacted indiana natural gas's on-call service person who arrived on the scene five minutes later (see attached time line). He and another responding indiana natural gas service person utilized cgi's to monitor the escaping gas, discussed the situation of with emergency responders and then excavated and shut off the service tee for the 1-inch line to stop gas flow and make the situation safe. The occupant of the vehicle was pronounced dead at the scene. Bartholomew county personnel theorized that the blowing gas could have caused the driver of the vehicle to asphyxiate. Indiana natural gas contacted indiana pipeline safety on-call personnel at 10:00 am to report the incident. Indiana natural gas contacted the national response center at 10:15 am to report the incident. An incident number of 1103941 was assigned by the nrc.
Detailed record list
Occurred At
2014-12-20 08:38:00
Year
2014
Report Received Date
2015-01-14 00:00:00
Iyear
2014.0
Report Number
20150002.0
Supplemental Number
16014.0
Report Type
Supplemental Final
Operator Id
Name
Indiana Natural Gas Corp
Operator Street Address
Po Box 520
Operator City Name
Washinton
Operator State Abbreviation
IN
Operator Postal Code
47501
Local Datetime
2014-12-20 07:47:00
Location Street Address
13417 W State Road 46
Location City Name
Columbus
Location County Name
Bartholomew
Location State Abbreviation
IN
Location Postal Code
47201-8729
Location Latitude
Location Longitude
Nrc Rpt Datetime
2014-12-20 10:10:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
63.0
Fatality Ind
Yes
Num Emp Fatalities
0
Num Contr Fatalities
0
Num Er Fatalities
0
Num Worker Fatalities
0
Num Gp Fatalities
1
Fatal
1
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2014-12-20 08:38:00
On Site Datetime
2014-12-20 08:43:00
Federal
No
Location Type
Public Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Farm Tap Meter/regulator Set
Installation Year
2001.0
Material Involved
Steel
Wt Steel
0.138
Release Type
Rupture
Rupture Orient
Circumferential
Rupture Length
1
Rupture Width
1
Class Location Type
Class 2 Location
Est Cost Oper Paid
25000.0
Est Cost Prop Damage
3000.0
Est Cost Emergency
2000.0
Est Cost Other
0.0
Est Cost Unintentional Release
300.0
Prpty
30300.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
2.0
Accident Psig
190.0
Normal Psig
190.0
Mop Psig
300.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Outside Force Type
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Vehicle Subtype
Third Party
Preparer Name
P****** S* R***
Preparer Title
General Manager
Preparer Email
P*****@i*************.com
Preparer Telephone
812-723-2151
Preparer Fax
812-723-2188
Authorizer Name
P****** S* R***
Authorizer Title
General Manager
Authorizer Telephone
812-723-2151
Authorizer Email
P*****@i*************.com
Narrative
On saturday, december 20, 2014 a driver of a passenger vehicle lost control while driving west on a rural section of indiana state road 46 west, west of columbus, indiana. The vehicle was observed to fishtail on an ice covered bridge over wolf creek. It skidded off the north side of the highway while spinning 180-degrees and rolling over on its side. The vehicle came to rest on top of an above ground 1-inch 190 psi to 3/4-inch 20 psi service line/regulator assembly owned by indiana natural gas corporation. The force of the impact sheared the 1-inch gas line downstream of the shutoff valve for the farm tap, causing a gas leak. The gas did not ignite. Bartholomew county fire department emergency responders arrived on scene and found the sole occupant of the vehicle unresponsive and without a pulse. They were unable to immediately extricate the occupant from the vehicle due to his size. Noting a gas leak, they retreated, donned self-contained breathing apparatus and tried again unsuccessfully to remove the occupant from the vehicle. Emergency responders notified dispatch that they needed the local gas company to respond to the gas leak. Bartholomew county dispatch contacted indiana natural gas's on-call service person who arrived on the scene five minutes later (see attached time line). He and another responding indiana natural gas service person utilized cgi's to monitor the escaping gas, discussed the situation of with emergency responders and then excavated and shut off the service tee for the 1-inch line to stop gas flow and make the situation safe. The occupant of the vehicle was pronounced dead at the scene. Bartholomew county personnel theorized that the blowing gas could have caused the driver of the vehicle to asphyxiate. Indiana natural gas contacted indiana pipeline safety on-call personnel at 10:00 am to report the incident. Indiana natural gas contacted the national response center at 10:15 am to report the incident. An incident number of 1103941 was assigned by the nrc.
Occurred At 2014-12-20 08:38:00
Year 2014
Report Received Date 2015-01-14 00:00:00
Iyear 2014.0
Report Number 20150002.0
Supplemental Number 16014.0
Report Type Supplemental Final
Operator Id 8080 PHMSA Enforcement
Name Indiana Natural Gas Corp
Operator Street Address Po Box 520
Operator City Name Washinton
Operator State Abbreviation IN
Operator Postal Code 47501
Local Datetime 2014-12-20 07:47:00
Location Street Address 13417 W State Road 46
Location City Name Columbus
Location County Name Bartholomew
Location State Abbreviation IN
Location Postal Code 47201-8729
Location Latitude 39.2002 Google Maps OpenStreetMap
Location Longitude -86.06731 Google Maps OpenStreetMap
Nrc Rpt Datetime 2014-12-20 10:10:00
Nrc Rpt Num 1103941 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 63.0
Fatality Ind Yes
Num Emp Fatalities 0
Num Contr Fatalities 0
Num Er Fatalities 0
Num Worker Fatalities 0
Num Gp Fatalities 1
Fatal 1
Injury Ind No
Injure 0
Ignite Ind No
Explode Ind No
Num Pub Evacuated 0.0
Incident Identified Datetime 2014-12-20 08:38:00
On Site Datetime 2014-12-20 08:43:00
Federal No
Location Type Public Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Farm Tap Meter/regulator Set
Installation Year 2001.0
Material Involved Steel
Wt Steel 0.138
Release Type Rupture
Rupture Orient Circumferential
Rupture Length 1
Rupture Width 1
Class Location Type Class 2 Location
Est Cost Oper Paid 25000.0
Est Cost Prop Damage 3000.0
Est Cost Emergency 2000.0
Est Cost Other 0.0
Est Cost Unintentional Release 300.0
Prpty 30300.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 2.0
Accident Psig 190.0
Normal Psig 190.0
Mop Psig 300.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Other Outside Force Damage
Cause Details Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Outside Force Type Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Vehicle Subtype Third Party
Preparer Name P****** S* R***
Preparer Title General Manager
Preparer Email P*****@i*************.com
Preparer Telephone 812-723-2151
Preparer Fax 812-723-2188
Authorizer Name P****** S* R***
Authorizer Title General Manager
Authorizer Telephone 812-723-2151
Authorizer Email P*****@i*************.com
Narrative On saturday, december 20, 2014 a driver of a passenger vehicle lost control while driving west on a rural section of indiana state road 46 west, west of columbus, indiana. The vehicle was observed to fishtail on an ice covered bridge over wolf creek. It skidded off the north side of the highway while spinning 180-degrees and rolling over on its side. The vehicle came to rest on top of an above ground 1-inch 190 psi to 3/4-inch 20 psi service line/regulator assembly owned by indiana natural gas corporation. The force of the impact sheared the 1-inch gas line downstream of the shutoff valve for the farm tap, causing a gas leak. The gas did not ignite. Bartholomew county fire department emergency responders arrived on scene and found the sole occupant of the vehicle unresponsive and without a pulse. They were unable to immediately extricate the occupant from the vehicle due to his size. Noting a gas leak, they retreated, donned self-contained breathing apparatus and tried again unsuccessfully to remove the occupant from the vehicle. Emergency responders notified dispatch that they needed the local gas company to respond to the gas leak. Bartholomew county dispatch contacted indiana natural gas's on-call service person who arrived on the scene five minutes later (see attached time line). He and another responding indiana natural gas service person utilized cgi's to monitor the escaping gas, discussed the situation of with emergency responders and then excavated and shut off the service tee for the 1-inch line to stop gas flow and make the situation safe. The occupant of the vehicle was pronounced dead at the scene. Bartholomew county personnel theorized that the blowing gas could have caused the driver of the vehicle to asphyxiate. Indiana natural gas contacted indiana pipeline safety on-call personnel at 10:00 am to report the incident. Indiana natural gas contacted the national response center at 10:15 am to report the incident. An incident number of 1103941 was assigned by the nrc.

All rights reserved. Copyright © by ClearPHMSA