HL incident on 2014-04-08 — TX

Operator
Sinclair Transportation Company
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$1,000
Incident datetime
2014-04-08 10:25
Report number
Location
TX
Narrative
On 4/7/2014 the patrol pilot reported a possible leak at 15:21. On 4/7 at 16:45 a sinclair employee responded to the report and was unable to find the leak site. The employee did not smell anything unusual and found a small pond of water adjacent to the row and assumed this was the condition called in by the pilot. On 4/8/2014 at 10:25 two sinclair employees found a 6' x 6' stain on row and could smell petroleum. They reported it internally at 10:30 cst and the controll center shutdown the line at 10:31 cst. Emergency 1-call submitted and sinclair maintenance dispatched to scene. Maintenance crews arrived at 15:00 and began excavating site. Pinhole corrosion leak found at 17:05. Patch welded on leak location at 17:30. On 4/9/14 sinclair pressured the affected segment to 217 psi and proof tested the line for 4 hours. Pressure actually increased to 222 psi on the blocked in section. On morning of 4/10/14 sinclair re-started the line with personnel at leak location visually inspecting pipe & repair. The investigation revealed that a piece of steel pipe found under the pipe at the leak location could have been the apparent cause of the pinhole corrosion leak. The steel pipe may have shielded the pipe from cathodic protection and caused a localized corrosion cell at this location. 2741 cubic yards of contaminated soil removed from leak site.
Detailed record list
Report Received Date
2014-05-22 00:00:00
Iyear
2014
Report Number
20140197
Supplemental Number
20217
Report Type
Supplemental Final
Operator Id
Name
Sinclair Transportation Company
Operator Street Address
2323 Victory Ave. Suite 1400
Operator City Name
Dallas
Operator State Abbreviation
TX
Operator Postal Code
75219
Local Datetime
2014-04-08 10:25:00
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Mixture Of Refined Products (Transmix Or Other Mixture)
Unintentional Release Bbls
80
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Air Patrol
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2014-04-08 10:25:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2014-04-08 10:31:00
Restart Datetime
2014-04-10 07:23:00
On Site Datetime
2014-04-08 10:25:00
Nrc Rpt Datetime
2014-04-08 10:48:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Mid Continent Pipeline
Segment Name
Carrollton - Montrose
Onshore State Abbreviation
Mo
Onshore Postal Code
63543
Onshore City Name
Gorin
Onshore County Name
Scotland
Designated Location
Milepost/valve Station
Designated Name
323
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
30
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8
Pipe Wall Thickness
0.322
Pipe Smys
24000
Pipe Specification
Unknown
Pipe Seam Type
Other
Pipe Seam Details
Unknown
Pipe Manufacturer
Unknown
Pipe Coating Type
None
Installation Year
Unknown
Manufactured Year
1930
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
210395
Est Cost Gas Released
10080
Est Cost Prop Damage
1000
Est Cost Emergency
1589
Est Cost Environmental
0
Est Cost Other
0
Prpty
223064
Accident Psig
92
Mop Psig
485
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
67904
Internal Inspection Ind
No
Other Restrictions Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Schedule Ind
Yes
Invest No Schedule Ind Details
In Reviewing Scada Data It Was Apparent That The Size Of The Pinhole Leak Was Undetectable By Scada Alarms And Events, Therefore, The Fatigue Issues Associated With Controller Shift Schedules, Schedule Rotations, Etc. Did Not Need To Be Investigated As Fatique, In No Way, Was A Contributing Factor To The Incident.
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1957
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2013
Close Interval Survey Year
2003
Prior Damage
No
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2012
Hydrtst Most Rcnt Pressure
727
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
J******* B****
Preparer Title
Regulatory Compliance Coordinator
Preparer Email
J*****@s**********.com
Preparer Telephone
307-328-3643
Preparer Fax
307-328-3571
Prepared Date
2015-03-09 00:00:00
Authorizer Name
M*** P*******
Authorizer Telephone
801-524-2852
Authorizer Title
President Transportation
Authorizer Email
M********@s**********.com
Narrative
On 4/7/2014 the patrol pilot reported a possible leak at 15:21. On 4/7 at 16:45 a sinclair employee responded to the report and was unable to find the leak site. The employee did not smell anything unusual and found a small pond of water adjacent to the row and assumed this was the condition called in by the pilot. On 4/8/2014 at 10:25 two sinclair employees found a 6' x 6' stain on row and could smell petroleum. They reported it internally at 10:30 cst and the controll center shutdown the line at 10:31 cst. Emergency 1-call submitted and sinclair maintenance dispatched to scene. Maintenance crews arrived at 15:00 and began excavating site. Pinhole corrosion leak found at 17:05. Patch welded on leak location at 17:30. On 4/9/14 sinclair pressured the affected segment to 217 psi and proof tested the line for 4 hours. Pressure actually increased to 222 psi on the blocked in section. On morning of 4/10/14 sinclair re-started the line with personnel at leak location visually inspecting pipe & repair. The investigation revealed that a piece of steel pipe found under the pipe at the leak location could have been the apparent cause of the pinhole corrosion leak. The steel pipe may have shielded the pipe from cathodic protection and caused a localized corrosion cell at this location. 2741 cubic yards of contaminated soil removed from leak site.
Report Received Date 2014-05-22 00:00:00
Iyear 2014
Report Number 20140197
Supplemental Number 20217
Report Type Supplemental Final
Operator Id 15156 PHMSA Enforcement
Name Sinclair Transportation Company
Operator Street Address 2323 Victory Ave. Suite 1400
Operator City Name Dallas
Operator State Abbreviation TX
Operator Postal Code 75219
Local Datetime 2014-04-08 10:25:00
Location Latitude 40.36474 Google Maps OpenStreetMap
Location Longitude -92.01656 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Mixture Of Refined Products (Transmix Or Other Mixture)
Unintentional Release Bbls 80
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Air Patrol
Operator Type Contractor Working For The Operator
Incident Identified Datetime 2014-04-08 10:25:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2014-04-08 10:31:00
Restart Datetime 2014-04-10 07:23:00
On Site Datetime 2014-04-08 10:25:00
Nrc Rpt Datetime 2014-04-08 10:48:00
Nrc Rpt Num 1079151 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Remotely Controlled
Downstream Valve Type Ind Remotely Controlled
Num Pub Evacuated 0
Pipe Fac Name Mid Continent Pipeline
Segment Name Carrollton - Montrose
Onshore State Abbreviation Mo
Onshore Postal Code 63543
Onshore City Name Gorin
Onshore County Name Scotland
Designated Location Milepost/valve Station
Designated Name 323
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 30
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 8
Pipe Wall Thickness 0.322
Pipe Smys 24000
Pipe Specification Unknown
Pipe Seam Type Other
Pipe Seam Details Unknown
Pipe Manufacturer Unknown
Pipe Coating Type None
Installation Year Unknown
Manufactured Year 1930
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 210395
Est Cost Gas Released 10080
Est Cost Prop Damage 1000
Est Cost Emergency 1589
Est Cost Environmental 0
Est Cost Other 0
Prpty 223064
Accident Psig 92
Mop Psig 485
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 67904
Internal Inspection Ind No
Other Restrictions Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest No Schedule Ind Yes
Invest No Schedule Ind Details In Reviewing Scada Data It Was Apparent That The Size Of The Pinhole Leak Was Undetectable By Scada Alarms And Events, Therefore, The Fatigue Issues Associated With Controller Shift Schedules, Schedule Rotations, Etc. Did Not Need To Be Investigated As Fatique, In No Way, Was A Contributing Factor To The Incident.
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1957
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2013
Close Interval Survey Year 2003
Prior Damage No
Collected Data Ind No
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2012
Hydrtst Most Rcnt Pressure 727
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name J******* B****
Preparer Title Regulatory Compliance Coordinator
Preparer Email J*****@s**********.com
Preparer Telephone 307-328-3643
Preparer Fax 307-328-3571
Prepared Date 2015-03-09 00:00:00
Authorizer Name M*** P*******
Authorizer Telephone 801-524-2852
Authorizer Title President Transportation
Authorizer Email M********@s**********.com
Narrative On 4/7/2014 the patrol pilot reported a possible leak at 15:21. On 4/7 at 16:45 a sinclair employee responded to the report and was unable to find the leak site. The employee did not smell anything unusual and found a small pond of water adjacent to the row and assumed this was the condition called in by the pilot. On 4/8/2014 at 10:25 two sinclair employees found a 6' x 6' stain on row and could smell petroleum. They reported it internally at 10:30 cst and the controll center shutdown the line at 10:31 cst. Emergency 1-call submitted and sinclair maintenance dispatched to scene. Maintenance crews arrived at 15:00 and began excavating site. Pinhole corrosion leak found at 17:05. Patch welded on leak location at 17:30. On 4/9/14 sinclair pressured the affected segment to 217 psi and proof tested the line for 4 hours. Pressure actually increased to 222 psi on the blocked in section. On morning of 4/10/14 sinclair re-started the line with personnel at leak location visually inspecting pipe & repair. The investigation revealed that a piece of steel pipe found under the pipe at the leak location could have been the apparent cause of the pinhole corrosion leak. The steel pipe may have shielded the pipe from cathodic protection and caused a localized corrosion cell at this location. 2741 cubic yards of contaminated soil removed from leak site.

All rights reserved. Copyright © by ClearPHMSA