GD incident on 2014-10-30 — IN

Operator
Community Natural Gas Inc
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 1 injury
Property damage (nominal)
$900
Incident datetime
2014-10-30 11:04
Report number
Location
IN, DUBOIS
Narrative
Around 11:00 am cst 10/30/14 contractor for the operator was making a tie-in for two 6" poly natural gas lines. 2" line comes off existing 6" line and feeds 8 households. New 6" line and existing 2" line are in close proximity. Laborer was digging with hand tools around those lines and the backhoe operator was removing dirt once it was uncovered. This area was uncovered the night before the incident and was approx. 20' long x 10' wide x 4' deep. Contractor was making hole longer to perform a tie in. While digging out excess dirt, 2" line went up and at near 90 deg angle. This is where a tooth from backhoe hit the line. Laborer turned around to cut off gas at 2" tap. Natural gas ignited before this could happen. Laborer caught on fire and sustained second degree burns to arms and face. No internal damages to laborer. No one else was hurt. No personal property was damaged. 11:21 am cst natural gas was shut off and fire department put out fire. Started shutting off meters in town. Made repairs to pipeline and started turning meters back on from 4:45 pm to 9:40 pm. Changed answering machine message at local office in dale. To let customers know we are aware of outage and left a cell phone number to call to get gas turned back on. 11 people went door to door to re-light customers. Only 8 customers were not able to be turned back on same night. Some houses were for sale and no one lived there. Furthermore, some customers were on vacation. Notes were left on those houses. All customers were able to be turned back on by 1:50 pm cst on 10/31/14.
Detailed record list
Occurred At
2014-10-30 11:04:00
Year
2014
Report Received Date
2014-11-04 00:00:00
Iyear
2014.0
Report Number
20140096.0
Supplemental Number
16059.0
Report Type
Supplemental Final
Operator Id
Name
Community Natural Gas Inc
Operator Street Address
116 N Main St
Operator City Name
Owensville
Operator State Abbreviation
IN
Operator Postal Code
47665
Local Datetime
2014-10-30 11:00:00
Location Street Address
West Side Of In161, East Side Of 2nd Ave, South Main Street
Location City Name
Holland
Location County Name
Dubois
Location State Abbreviation
IN
Location Postal Code
47541
Location Latitude
Location Longitude
Nrc Rpt Datetime
2014-10-30 12:33:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
105.0
Fatality Ind
No
Fatal
0
Injury Ind
Yes
Num Emp Injuries
0
Num Contr Injuries
1
Num Er Injuries
0
Num Worker Injuries
0
Num Gp Injuries
0
Injure
1
Ignite Ind
Yes
Explode Ind
Yes
Num Pub Evacuated
75.0
Incident Identified Datetime
2014-10-30 11:04:00
On Site Datetime
2014-10-30 11:12:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
48.0
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
2013.0
Pipe Diameter
2.0
Pipe Specification
Poly 2406
Pipe Manufacturer
Drisplex
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
1.0
Puncture Circum
0.5
Class Location Type
Class 2 Location
Est Cost Oper Paid
90000.0
Est Cost Prop Damage
900.0
Est Cost Emergency
7185.0
Est Cost Other
0.0
Est Cost Unintentional Release
578.0
Prpty
98663.0
Commercial Affected
25.0
Industrial Affected
1.0
Residences Affected
225.0
Accident Psig
50.0
Normal Psig
50.0
Mop Psig
60.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Third Party That Caused The Incident
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
Yes
Num Contractors Tested
1
Num Contractors Failed
0
Cause
Excavation Damage
Cause Details
Excavation Damage By Operator's Contractor (Second Party)
Ex Party Type
Excavation Damage By Operator's Contractor (Second Party)
Ex Hydrotest Leak Survey Date
2010-07-21 00:00:00
Ex Hydrotest Conducted Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Easement
Excavator Type
Contractor
Excavator Equipment
Backhoe/trackhoe
Work Performed
Natural Gas
One Call Notified Ind
Yes
One Call Ticket Num
1410202080
Locator Type
Utility Owner
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
27.0
Root Cause Category
Excavation Issue
Root Cause Type
Improper Excavation Practice Not Listed Above
Preparer Name
D*** J* K******
Preparer Title
Operations Manager
Preparer Email
D***@c******************.com
Preparer Telephone
6189724060
Preparer Fax
6182633215
Authorizer Name
D*** J* K******
Authorizer Title
Operations Manager
Authorizer Telephone
6182633328
Authorizer Email
D***@c******************.com
Narrative
Around 11:00 am cst 10/30/14 contractor for the operator was making a tie-in for two 6" poly natural gas lines. 2" line comes off existing 6" line and feeds 8 households. New 6" line and existing 2" line are in close proximity. Laborer was digging with hand tools around those lines and the backhoe operator was removing dirt once it was uncovered. This area was uncovered the night before the incident and was approx. 20' long x 10' wide x 4' deep. Contractor was making hole longer to perform a tie in. While digging out excess dirt, 2" line went up and at near 90 deg angle. This is where a tooth from backhoe hit the line. Laborer turned around to cut off gas at 2" tap. Natural gas ignited before this could happen. Laborer caught on fire and sustained second degree burns to arms and face. No internal damages to laborer. No one else was hurt. No personal property was damaged. 11:21 am cst natural gas was shut off and fire department put out fire. Started shutting off meters in town. Made repairs to pipeline and started turning meters back on from 4:45 pm to 9:40 pm. Changed answering machine message at local office in dale. To let customers know we are aware of outage and left a cell phone number to call to get gas turned back on. 11 people went door to door to re-light customers. Only 8 customers were not able to be turned back on same night. Some houses were for sale and no one lived there. Furthermore, some customers were on vacation. Notes were left on those houses. All customers were able to be turned back on by 1:50 pm cst on 10/31/14.
Occurred At 2014-10-30 11:04:00
Year 2014
Report Received Date 2014-11-04 00:00:00
Iyear 2014.0
Report Number 20140096.0
Supplemental Number 16059.0
Report Type Supplemental Final
Operator Id 2676 PHMSA Enforcement
Name Community Natural Gas Inc
Operator Street Address 116 N Main St
Operator City Name Owensville
Operator State Abbreviation IN
Operator Postal Code 47665
Local Datetime 2014-10-30 11:00:00
Location Street Address West Side Of In161, East Side Of 2nd Ave, South Main Street
Location City Name Holland
Location County Name Dubois
Location State Abbreviation IN
Location Postal Code 47541
Location Latitude 38.144527 Google Maps OpenStreetMap
Location Longitude -87.2101 Google Maps OpenStreetMap
Nrc Rpt Datetime 2014-10-30 12:33:00
Nrc Rpt Num 1099761 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 105.0
Fatality Ind No
Fatal 0
Injury Ind Yes
Num Emp Injuries 0
Num Contr Injuries 1
Num Er Injuries 0
Num Worker Injuries 0
Num Gp Injuries 0
Injure 1
Ignite Ind Yes
Explode Ind Yes
Num Pub Evacuated 75.0
Incident Identified Datetime 2014-10-30 11:04:00
On Site Datetime 2014-10-30 11:12:00
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 48.0
Crossing No
Pipe Facility Type Privately Owned
System Part Involved Main
Installation Year 2013.0
Pipe Diameter 2.0
Pipe Specification Poly 2406
Pipe Manufacturer Drisplex
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11
Material Pe Pipe Code 2406
Release Type Mechanical Puncture
Puncture Axial 1.0
Puncture Circum 0.5
Class Location Type Class 2 Location
Est Cost Oper Paid 90000.0
Est Cost Prop Damage 900.0
Est Cost Emergency 7185.0
Est Cost Other 0.0
Est Cost Unintentional Release 578.0
Prpty 98663.0
Commercial Affected 25.0
Industrial Affected 1.0
Residences Affected 225.0
Accident Psig 50.0
Normal Psig 50.0
Mop Psig 60.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Third Party That Caused The Incident
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind Yes
Num Contractors Tested 1
Num Contractors Failed 0
Cause Excavation Damage
Cause Details Excavation Damage By Operator's Contractor (Second Party)
Ex Party Type Excavation Damage By Operator's Contractor (Second Party)
Ex Hydrotest Leak Survey Date 2010-07-21 00:00:00
Ex Hydrotest Conducted Ind No
Notify Cga Dirt No
Private Row Ind Yes
Private Subtype Private Easement
Excavator Type Contractor
Excavator Equipment Backhoe/trackhoe
Work Performed Natural Gas
One Call Notified Ind Yes
One Call Ticket Num 1410202080
Locator Type Utility Owner
Visible Marks Yes
Service Interruption Yes
Service Interruption Hours 27.0
Root Cause Category Excavation Issue
Root Cause Type Improper Excavation Practice Not Listed Above
Preparer Name D*** J* K******
Preparer Title Operations Manager
Preparer Email D***@c******************.com
Preparer Telephone 6189724060
Preparer Fax 6182633215
Authorizer Name D*** J* K******
Authorizer Title Operations Manager
Authorizer Telephone 6182633328
Authorizer Email D***@c******************.com
Narrative Around 11:00 am cst 10/30/14 contractor for the operator was making a tie-in for two 6" poly natural gas lines. 2" line comes off existing 6" line and feeds 8 households. New 6" line and existing 2" line are in close proximity. Laborer was digging with hand tools around those lines and the backhoe operator was removing dirt once it was uncovered. This area was uncovered the night before the incident and was approx. 20' long x 10' wide x 4' deep. Contractor was making hole longer to perform a tie in. While digging out excess dirt, 2" line went up and at near 90 deg angle. This is where a tooth from backhoe hit the line. Laborer turned around to cut off gas at 2" tap. Natural gas ignited before this could happen. Laborer caught on fire and sustained second degree burns to arms and face. No internal damages to laborer. No one else was hurt. No personal property was damaged. 11:21 am cst natural gas was shut off and fire department put out fire. Started shutting off meters in town. Made repairs to pipeline and started turning meters back on from 4:45 pm to 9:40 pm. Changed answering machine message at local office in dale. To let customers know we are aware of outage and left a cell phone number to call to get gas turned back on. 11 people went door to door to re-light customers. Only 8 customers were not able to be turned back on same night. Some houses were for sale and no one lived there. Furthermore, some customers were on vacation. Notes were left on those houses. All customers were able to be turned back on by 1:50 pm cst on 10/31/14.