GD incident on 2014-02-18 — CA

Operator
Southern California Gas Co
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$1,240,000
Incident datetime
2014-02-18 21:48
Report number
Location
CA, SAN BERNARDINO
Narrative
On february 18, 2014 socalgas was notified of a gas leak at 9506 central ave in montclair. Monte vista water district indicated they were working on a water leak on their main in the intersection of central ave and palo verde and detected gas while excavating. Gas crews responded and confirmed leakage and that the water had entered the gas main. The water crews isolated the water main at the incursion point and socalgas excavated and repaired the gas leak with a clamp. While the gas leak was being brought under control, socalgas began investigating the area to determine the extent of the water incursion. Numerous locations were identified due to low elevation and ends of the distribution system as water extraction points. Over the course of the next five days, approximately 6,100 gallons of water was extracted from the gas lines and 1,751 impacted meters were replaced. As of 22:00 on 2-23-14, all impacted customers had either been restored or, if contact could not be made because of vacant residences, memos were placed on the accounts and literature left at the residence on how to contact socalgas for restoration of gas service. Investigation revealed that the water main, located perpendicular to and directly above the gas main had a corrosion leak on the bottom of the pipe. That water leak, over time, bored a hole into the top of the gas main. The water pressure was approximately 100 psig and the gas was operating at 45 psig which allowed the water to enter the gas main. The gas main was repaired with a clamp, the water main was replaced at the crossing. This incident was reported to PHMSA due to the anticipated costs of the incident would exceed $50,000. This incident was also reported to the cpuc.
Detailed record list
Occurred At
2014-02-18 21:48:00
Year
2014
Report Received Date
2014-03-18 00:00:00
Iyear
2014.0
Report Number
20140023.0
Supplemental Number
15822.0
Report Type
Original Final
Operator Id
Name
Southern California Gas Co
Operator Street Address
555 West Fifth Street
Operator City Name
Los Angeles
Operator State Abbreviation
CA
Operator Postal Code
90013
Local Datetime
2014-02-18 21:48:00
Location Street Address
9506 Central Ave
Location City Name
Montclair
Location County Name
San Bernardino
Location State Abbreviation
CA
Location Postal Code
91736
Location Latitude
Location Longitude
Nrc Rpt Datetime
2014-02-19 06:20:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
548.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2014-02-18 21:48:00
On Site Datetime
2014-02-18 22:10:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
45.0
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
1959.0
Pipe Diameter
8.625
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Unknown
Release Type
Mechanical Puncture
Puncture Axial
1.0
Puncture Circum
1.0
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
1240000.0
Est Cost Emergency
2000.0
Est Cost Other
0.0
Est Cost Unintentional Release
3288.0
Prpty
1245288.0
Commercial Affected
63.0
Industrial Affected
0.0
Residences Affected
1688.0
Accident Psig
45.0
Normal Psig
45.0
Mop Psig
60.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Third Party That Caused The Incident
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Other Outside Force Damage
Outside Force Type
Other Outside Force Damage
Osf Other Details
High Pressure Water Bored Hole Into 8" Steel Natrual Gas Main.
Preparer Name
T*** A* B****
Preparer Title
Pipeline Safety And Compliance Advisor
Preparer Email
T*****@s**************.com
Preparer Telephone
909-376-7208
Preparer Fax
909-885-6270
Authorizer Name
T*** A* B****
Authorizer Title
Pipeline Safety And Compliance Advisor
Authorizer Telephone
909-376-7208
Authorizer Email
T*****@s**************.com
Narrative
On february 18, 2014 socalgas was notified of a gas leak at 9506 central ave in montclair. Monte vista water district indicated they were working on a water leak on their main in the intersection of central ave and palo verde and detected gas while excavating. Gas crews responded and confirmed leakage and that the water had entered the gas main. The water crews isolated the water main at the incursion point and socalgas excavated and repaired the gas leak with a clamp. While the gas leak was being brought under control, socalgas began investigating the area to determine the extent of the water incursion. Numerous locations were identified due to low elevation and ends of the distribution system as water extraction points. Over the course of the next five days, approximately 6,100 gallons of water was extracted from the gas lines and 1,751 impacted meters were replaced. As of 22:00 on 2-23-14, all impacted customers had either been restored or, if contact could not be made because of vacant residences, memos were placed on the accounts and literature left at the residence on how to contact socalgas for restoration of gas service. Investigation revealed that the water main, located perpendicular to and directly above the gas main had a corrosion leak on the bottom of the pipe. That water leak, over time, bored a hole into the top of the gas main. The water pressure was approximately 100 psig and the gas was operating at 45 psig which allowed the water to enter the gas main. The gas main was repaired with a clamp, the water main was replaced at the crossing. This incident was reported to PHMSA due to the anticipated costs of the incident would exceed $50,000. This incident was also reported to the cpuc.
Occurred At 2014-02-18 21:48:00
Year 2014
Report Received Date 2014-03-18 00:00:00
Iyear 2014.0
Report Number 20140023.0
Supplemental Number 15822.0
Report Type Original Final
Operator Id 18484 PHMSA Enforcement
Name Southern California Gas Co
Operator Street Address 555 West Fifth Street
Operator City Name Los Angeles
Operator State Abbreviation CA
Operator Postal Code 90013
Local Datetime 2014-02-18 21:48:00
Location Street Address 9506 Central Ave
Location City Name Montclair
Location County Name San Bernardino
Location State Abbreviation CA
Location Postal Code 91736
Location Latitude 34.08131 Google Maps OpenStreetMap
Location Longitude -117.68963 Google Maps OpenStreetMap
Nrc Rpt Datetime 2014-02-19 06:20:00
Nrc Rpt Num 1074442 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 548.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind No
Explode Ind No
Num Pub Evacuated 0.0
Incident Identified Datetime 2014-02-18 21:48:00
On Site Datetime 2014-02-18 22:10:00
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Under Pavement
Depth Of Cover 45.0
Crossing Yes
Road Crossing Ind Yes
Road Type Uncased
Pipe Facility Type Privately Owned
System Part Involved Main
Installation Year 1959.0
Pipe Diameter 8.625
Pipe Specification Unknown
Pipe Manufacturer Unknown
Material Involved Steel
Steel Seam Type Other
Steel Seam Type Details Unknown
Release Type Mechanical Puncture
Puncture Axial 1.0
Puncture Circum 1.0
Class Location Type Class 3 Location
Est Cost Oper Paid 0.0
Est Cost Prop Damage 1240000.0
Est Cost Emergency 2000.0
Est Cost Other 0.0
Est Cost Unintentional Release 3288.0
Prpty 1245288.0
Commercial Affected 63.0
Industrial Affected 0.0
Residences Affected 1688.0
Accident Psig 45.0
Normal Psig 45.0
Mop Psig 60.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Third Party That Caused The Incident
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Other Outside Force Damage
Cause Details Other Outside Force Damage
Outside Force Type Other Outside Force Damage
Osf Other Details High Pressure Water Bored Hole Into 8" Steel Natrual Gas Main.
Preparer Name T*** A* B****
Preparer Title Pipeline Safety And Compliance Advisor
Preparer Email T*****@s**************.com
Preparer Telephone 909-376-7208
Preparer Fax 909-885-6270
Authorizer Name T*** A* B****
Authorizer Title Pipeline Safety And Compliance Advisor
Authorizer Telephone 909-376-7208
Authorizer Email T*****@s**************.com
Narrative On february 18, 2014 socalgas was notified of a gas leak at 9506 central ave in montclair. Monte vista water district indicated they were working on a water leak on their main in the intersection of central ave and palo verde and detected gas while excavating. Gas crews responded and confirmed leakage and that the water had entered the gas main. The water crews isolated the water main at the incursion point and socalgas excavated and repaired the gas leak with a clamp. While the gas leak was being brought under control, socalgas began investigating the area to determine the extent of the water incursion. Numerous locations were identified due to low elevation and ends of the distribution system as water extraction points. Over the course of the next five days, approximately 6,100 gallons of water was extracted from the gas lines and 1,751 impacted meters were replaced. As of 22:00 on 2-23-14, all impacted customers had either been restored or, if contact could not be made because of vacant residences, memos were placed on the accounts and literature left at the residence on how to contact socalgas for restoration of gas service. Investigation revealed that the water main, located perpendicular to and directly above the gas main had a corrosion leak on the bottom of the pipe. That water leak, over time, bored a hole into the top of the gas main. The water pressure was approximately 100 psig and the gas was operating at 45 psig which allowed the water to enter the gas main. The gas main was repaired with a clamp, the water main was replaced at the crossing. This incident was reported to PHMSA due to the anticipated costs of the incident would exceed $50,000. This incident was also reported to the cpuc.

All rights reserved. Copyright © by ClearPHMSA