HL incident on 2013-09-29 — TX
Operator
Tesoro High Plains Pipeline Company Llc
Cause
Natural Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$269,051
Incident datetime
2013-09-29 21:36
Report number
Location
TX
Narrative
On september 29, 2013, tesoro high plains pipeline (thpp) personnel were notified of a possible crude oil release from a pipeline approximately 9 miles north of tioga, nd. Local thpp personnel immediately notified the control center which shutdown the pipeline. Thpp response personnel were dispatched to the site and federal and state authorities were notified (I.E. Nrc and nd state radio). The pipeline was excavated and the release source (a small hole) was clamped. A subsurface assessment of the affected soil has estimated the total spill volume at 20,600 bbls. The affected pipe was removed and sent to a laboratory for metallurgical analysis. The report from the metallurgical laboratory determined that the hole resulted from an electrical discharge. The laboratory also determined that there was no evidence of corrosion or mechanical damage. The root cause analysis investigation determined the electrical discharge was most likely the result of a lightning strike. Although the exact date of the lightning strike is unknown, the investigation concluded that it most likely occurred between july 29 and august 9, 2013. Per PHMSA guidance, this report is being submitted as a "final" report because the accident response consists of only long term remediation which is being conducted under the auspices of the north dakota department of health.
Detailed record list
Report Received Date
2013-10-29 00:00:00
Iyear
2013
Report Number
20130353
Supplemental Number
19930
Report Type
Supplemental Final
Operator Id
31570
Name
Tesoro High Plains Pipeline Company Llc
Operator Street Address
19100 Ridgewood Parkway
Operator City Name
San Antonio
Operator State Abbreviation
TX
Operator Postal Code
78259
Local Datetime
2013-07-29 00:00:00
Location Latitude
48.524251
Location Longitude
-102.856912
Commodity Released Type
Crude Oil
Unintentional Release Bbls
20600
Recovered Bbls
5856
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2013-09-29 21:36:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2013-09-29 21:47:00
Restart Datetime
2013-11-01 10:40:00
On Site Datetime
2013-09-29 22:15:00
Nrc Rpt Datetime
2013-09-30 00:16:00
Nrc Rpt Num
1061615
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Tesoro High Plains Pipeline
Segment Name
Tioga To Black Slough
Onshore State Abbreviation
Nd
Onshore Postal Code
58852
Onshore County Name
Mountrail
Designated Location
Milepost/valve Station
Designated Name
29.6
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
6.625
Pipe Wall Thickness
0.219
Pipe Smys
42000
Pipe Specification
X-42
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Ipsco
Pipe Coating Type
Extruded Polyehylene
Installation Year
1993
Manufactured Year
1993
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
10/32" Hole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
168000
Est Cost Gas Released
1417839
Est Cost Prop Damage
269051
Est Cost Emergency
4100000
Est Cost Environmental
11031800
Est Cost Other
0
Prpty
16986690
Accident Psig
350
Mop Psig
1390
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
93614
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Lightning
Natural Force Type
Lightning
Lightning Subtype
Direct Hit
Nf Extreme Weather Ind
No
Preparer Name
A**** W* M*******
Preparer Title
Manager Dot Compliance
Preparer Email
A***************@t******.com
Preparer Telephone
2106266343
Prepared Date
2014-12-02 00:00:00
Authorizer Name
A**** W* M*******
Authorizer Telephone
210-626-6343
Authorizer Title
Dot Compliance Manager
Authorizer Email
A***************@t******.com
Narrative
On september 29, 2013, tesoro high plains pipeline (thpp) personnel were notified of a possible crude oil release from a pipeline approximately 9 miles north of tioga, nd. Local thpp personnel immediately notified the control center which shutdown the pipeline. Thpp response personnel were dispatched to the site and federal and state authorities were notified (I.E. Nrc and nd state radio). The pipeline was excavated and the release source (a small hole) was clamped. A subsurface assessment of the affected soil has estimated the total spill volume at 20,600 bbls. The affected pipe was removed and sent to a laboratory for metallurgical analysis. The report from the metallurgical laboratory determined that the hole resulted from an electrical discharge. The laboratory also determined that there was no evidence of corrosion or mechanical damage. The root cause analysis investigation determined the electrical discharge was most likely the result of a lightning strike. Although the exact date of the lightning strike is unknown, the investigation concluded that it most likely occurred between july 29 and august 9, 2013. Per PHMSA guidance, this report is being submitted as a "final" report because the accident response consists of only long term remediation which is being conducted under the auspices of the north dakota department of health.
| Report Received Date | 2013-10-29 00:00:00 |
|---|---|
| Iyear | 2013 |
| Report Number | 20130353 |
| Supplemental Number | 19930 |
| Report Type | Supplemental Final |
| Operator Id | 31570 PHMSA Enforcement |
| Name | Tesoro High Plains Pipeline Company Llc |
| Operator Street Address | 19100 Ridgewood Parkway |
| Operator City Name | San Antonio |
| Operator State Abbreviation | TX |
| Operator Postal Code | 78259 |
| Local Datetime | 2013-07-29 00:00:00 |
| Location Latitude | 48.524251 Google Maps OpenStreetMap |
| Location Longitude | -102.856912 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 20600 |
| Recovered Bbls | 5856 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Public |
| Incident Identified Datetime | 2013-09-29 21:36:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2013-09-29 21:47:00 |
| Restart Datetime | 2013-11-01 10:40:00 |
| On Site Datetime | 2013-09-29 22:15:00 |
| Nrc Rpt Datetime | 2013-09-30 00:16:00 |
| Nrc Rpt Num | 1061615 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Tesoro High Plains Pipeline |
| Segment Name | Tioga To Black Slough |
| Onshore State Abbreviation | Nd |
| Onshore Postal Code | 58852 |
| Onshore County Name | Mountrail |
| Designated Location | Milepost/valve Station |
| Designated Name | 29.6 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 48 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 6.625 |
| Pipe Wall Thickness | 0.219 |
| Pipe Smys | 42000 |
| Pipe Specification | X-42 |
| Pipe Seam Type | Erw - High Frequency |
| Pipe Manufacturer | Ipsco |
| Pipe Coating Type | Extruded Polyehylene |
| Installation Year | 1993 |
| Manufactured Year | 1993 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | 10/32" Hole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | Yes |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 168000 |
| Est Cost Gas Released | 1417839 |
| Est Cost Prop Damage | 269051 |
| Est Cost Emergency | 4100000 |
| Est Cost Environmental | 11031800 |
| Est Cost Other | 0 |
| Prpty | 16986690 |
| Accident Psig | 350 |
| Mop Psig | 1390 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 93614 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Natural Force Damage |
| Cause Details | Lightning |
| Natural Force Type | Lightning |
| Lightning Subtype | Direct Hit |
| Nf Extreme Weather Ind | No |
| Preparer Name | A**** W* M******* |
| Preparer Title | Manager Dot Compliance |
| Preparer Email | A***************@t******.com |
| Preparer Telephone | 2106266343 |
| Prepared Date | 2014-12-02 00:00:00 |
| Authorizer Name | A**** W* M******* |
| Authorizer Telephone | 210-626-6343 |
| Authorizer Title | Dot Compliance Manager |
| Authorizer Email | A***************@t******.com |
| Narrative | On september 29, 2013, tesoro high plains pipeline (thpp) personnel were notified of a possible crude oil release from a pipeline approximately 9 miles north of tioga, nd. Local thpp personnel immediately notified the control center which shutdown the pipeline. Thpp response personnel were dispatched to the site and federal and state authorities were notified (I.E. Nrc and nd state radio). The pipeline was excavated and the release source (a small hole) was clamped. A subsurface assessment of the affected soil has estimated the total spill volume at 20,600 bbls. The affected pipe was removed and sent to a laboratory for metallurgical analysis. The report from the metallurgical laboratory determined that the hole resulted from an electrical discharge. The laboratory also determined that there was no evidence of corrosion or mechanical damage. The root cause analysis investigation determined the electrical discharge was most likely the result of a lightning strike. Although the exact date of the lightning strike is unknown, the investigation concluded that it most likely occurred between july 29 and august 9, 2013. Per PHMSA guidance, this report is being submitted as a "final" report because the accident response consists of only long term remediation which is being conducted under the auspices of the north dakota department of health. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA