HL incident on 2013-09-04 — TX
Operator
Nustar Logistics, L.p.
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$109,184
Incident datetime
2013-09-04 07:40
Report number
Location
TX
Narrative
On tuesday, september 3, 2013, nustar's control room in san antonio, tx received a low-suction alarm on nustar's 8-inch 53p three rivers to san antonio (south) pipeline system. The three rivers pump station was automatically shut down on the alarm, and the pump station discharge valve was closed. Throughout the evening of september 3rd and early morning of september 4th, nustar personnel drove the entire pipeline segment from three rivers, tx to nustar's san antonio south terminal checking immediate response areas. On wednesday, september 4, 2013, nustar personnel discovered a release on the row of the pipeline approximately 0.5 miles north of hwy 72 near three rivers, tx. The accident occurred in a rural, non-hca location in live oak county, tx. Approximately 2,752 barrels of gasoline was released, and approximately 817 barrels have been recovered to-date. The affected pipe segment was removed and replaced on thursday, september 5, 2013. The affected pipe segment was sent to a third party metallurgical laboratory for analysis. The rupture was caused by external corrosion underneath tape coating applied over the girth weld region. The corrosion was isolated to the pipe beneath the tape coating. The corrosion progressed to a depth where the remaining wall thickness was unable to contain the internal pressure.
Detailed record list
Report Received Date
2013-10-03 00:00:00
Iyear
2013
Report Number
20130332
Supplemental Number
18957
Report Type
Supplemental Final
Operator Id
31454
Name
Nustar Logistics, L.p.
Operator Street Address
8111 Westchester Drive
Operator City Name
Dallas
Operator State Abbreviation
TX
Operator Postal Code
75225
Local Datetime
2013-09-03 21:34:00
Location Latitude
28.488488
Location Longitude
-98.160559
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
2752
Recovered Bbls
817
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Cpm Leak Detection System Or Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Calculations)
Incident Identified Datetime
2013-09-04 07:40:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2013-09-03 21:34:00
Restart Datetime
2013-09-05 21:09:00
On Site Datetime
2013-09-04 07:40:00
Nrc Rpt Datetime
2013-09-04 07:57:00
Nrc Rpt Num
1059132
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Automatic
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
53p-Three Rivers To San Antonio (South) Pl
Segment Name
Three Rivers To San Antonio South Terminal
Onshore State Abbreviation
Tx
Onshore Postal Code
78071
Onshore City Name
Three Rivers
Onshore County Name
Live Oak
Designated Location
Survey Station No.
Designated Name
222+34
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
54
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8.625
Pipe Wall Thickness
0.219
Pipe Smys
52000
Pipe Specification
Api 5l
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Dalmine
Pipe Coating Type
Cold Applied Tape
Installation Year
1979
Manufactured Year
1978
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Width
3.1
Rupture Length
14.3
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
1045900
Est Cost Gas Released
217560
Est Cost Prop Damage
109184
Est Cost Emergency
151051
Est Cost Environmental
200000
Est Cost Other
0
Prpty
1723695
Accident Psig
1742
Mop Psig
1865
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
48854
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
Yes
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The scada system responded automatically to the low-suction alarm. Nustar control room personnel recognized the event and responded appropriately.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Metallurgical Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1979
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2013
Close Interval Survey Year
2009
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2009
Geometry Recent Year
2009
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
R****** P****
Preparer Title
Lead Pipeline Safety Specialist
Preparer Email
R************@n***********.com
Preparer Telephone
361-249-9417
Preparer Fax
210-918-7117
Prepared Date
2014-01-27 00:00:00
Authorizer Name
W** G***
Authorizer Telephone
361-249-9402
Authorizer Title
Vice President And General Manager Operations
Authorizer Email
W*******@n***********.com
Narrative
On tuesday, september 3, 2013, nustar's control room in san antonio, tx received a low-suction alarm on nustar's 8-inch 53p three rivers to san antonio (south) pipeline system. The three rivers pump station was automatically shut down on the alarm, and the pump station discharge valve was closed. Throughout the evening of september 3rd and early morning of september 4th, nustar personnel drove the entire pipeline segment from three rivers, tx to nustar's san antonio south terminal checking immediate response areas. On wednesday, september 4, 2013, nustar personnel discovered a release on the row of the pipeline approximately 0.5 miles north of hwy 72 near three rivers, tx. The accident occurred in a rural, non-hca location in live oak county, tx. Approximately 2,752 barrels of gasoline was released, and approximately 817 barrels have been recovered to-date. The affected pipe segment was removed and replaced on thursday, september 5, 2013. The affected pipe segment was sent to a third party metallurgical laboratory for analysis. The rupture was caused by external corrosion underneath tape coating applied over the girth weld region. The corrosion was isolated to the pipe beneath the tape coating. The corrosion progressed to a depth where the remaining wall thickness was unable to contain the internal pressure.
| Report Received Date | 2013-10-03 00:00:00 |
|---|---|
| Iyear | 2013 |
| Report Number | 20130332 |
| Supplemental Number | 18957 |
| Report Type | Supplemental Final |
| Operator Id | 31454 PHMSA Enforcement |
| Name | Nustar Logistics, L.p. |
| Operator Street Address | 8111 Westchester Drive |
| Operator City Name | Dallas |
| Operator State Abbreviation | TX |
| Operator Postal Code | 75225 |
| Local Datetime | 2013-09-03 21:34:00 |
| Location Latitude | 28.488488 Google Maps OpenStreetMap |
| Location Longitude | -98.160559 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Gasoline (Non-Ethanol) |
| Unintentional Release Bbls | 2752 |
| Recovered Bbls | 817 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Cpm Leak Detection System Or Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Calculations) |
| Incident Identified Datetime | 2013-09-04 07:40:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2013-09-03 21:34:00 |
| Restart Datetime | 2013-09-05 21:09:00 |
| On Site Datetime | 2013-09-04 07:40:00 |
| Nrc Rpt Datetime | 2013-09-04 07:57:00 |
| Nrc Rpt Num | 1059132 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Automatic |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | 53p-Three Rivers To San Antonio (South) Pl |
| Segment Name | Three Rivers To San Antonio South Terminal |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 78071 |
| Onshore City Name | Three Rivers |
| Onshore County Name | Live Oak |
| Designated Location | Survey Station No. |
| Designated Name | 222+34 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 54 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 8.625 |
| Pipe Wall Thickness | 0.219 |
| Pipe Smys | 52000 |
| Pipe Specification | Api 5l |
| Pipe Seam Type | Erw - High Frequency |
| Pipe Manufacturer | Dalmine |
| Pipe Coating Type | Cold Applied Tape |
| Installation Year | 1979 |
| Manufactured Year | 1978 |
| Material Involved | Carbon Steel |
| Release Type | Rupture |
| Rupture Orient | Longitudinal |
| Rupture Width | 3.1 |
| Rupture Length | 14.3 |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | Yes |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 1045900 |
| Est Cost Gas Released | 217560 |
| Est Cost Prop Damage | 109184 |
| Est Cost Emergency | 151051 |
| Est Cost Environmental | 200000 |
| Est Cost Other | 0 |
| Prpty | 1723695 |
| Accident Psig | 1742 |
| Mop Psig | 1865 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 48854 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | Yes |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | Yes |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The scada system responded automatically to the low-suction alarm. Nustar control room personnel recognized the event and responded appropriately. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Galvanic Corrosion Ind | Yes |
| Field Exam Basis Ind | Yes |
| Metallurgical Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | Yes |
| Cathodic Pro Start Year | 1979 |
| Shielding Evident | Yes |
| Cathodic Survey Type | Yes |
| Cp Annual Survey Ind | Yes |
| Close Interval Survey Ind | Yes |
| Cp Annual Survey Year | 2013 |
| Close Interval Survey Year | 2009 |
| Prior Damage | Yes |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Geometry Deformation Ind | Yes |
| Axial Recent Year | 2009 |
| Geometry Recent Year | 2009 |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | R****** P**** |
| Preparer Title | Lead Pipeline Safety Specialist |
| Preparer Email | R************@n***********.com |
| Preparer Telephone | 361-249-9417 |
| Preparer Fax | 210-918-7117 |
| Prepared Date | 2014-01-27 00:00:00 |
| Authorizer Name | W** G*** |
| Authorizer Telephone | 361-249-9402 |
| Authorizer Title | Vice President And General Manager Operations |
| Authorizer Email | W*******@n***********.com |
| Narrative | On tuesday, september 3, 2013, nustar's control room in san antonio, tx received a low-suction alarm on nustar's 8-inch 53p three rivers to san antonio (south) pipeline system. The three rivers pump station was automatically shut down on the alarm, and the pump station discharge valve was closed. Throughout the evening of september 3rd and early morning of september 4th, nustar personnel drove the entire pipeline segment from three rivers, tx to nustar's san antonio south terminal checking immediate response areas. On wednesday, september 4, 2013, nustar personnel discovered a release on the row of the pipeline approximately 0.5 miles north of hwy 72 near three rivers, tx. The accident occurred in a rural, non-hca location in live oak county, tx. Approximately 2,752 barrels of gasoline was released, and approximately 817 barrels have been recovered to-date. The affected pipe segment was removed and replaced on thursday, september 5, 2013. The affected pipe segment was sent to a third party metallurgical laboratory for analysis. The rupture was caused by external corrosion underneath tape coating applied over the girth weld region. The corrosion was isolated to the pipe beneath the tape coating. The corrosion progressed to a depth where the remaining wall thickness was unable to contain the internal pressure. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA