Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2013-07-22 — TX
Operator
The Dow Chemical Company
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$30,000
Incident datetime
2013-07-22 15:30
Report number
Location
TX
Narrative
On july 22, 2013, the dow chemical company officially reported a leak on a pygas pipeline, dpl-191. The national response center report number for this incident is 1054720 and the railroad commission of texas incident number is 825. Low pressure hydrotesting the line confirmed that the pipeline had a pinhole leak in a girth weld. Metallurgical analysis from cut-outs taken of the line indicated that brine water constituents from the pygas storage well were a probable cause of the internal corrosion in the locally affected zone closest to the storage well (area where pinhole leak was found). Once the leak was discovered, the line was shut down, cleaned and cleared. Currently, dow is assessing the pipeline for any further corrosion or issues. The surrounding area has been properly remediated and all product has been recovered. On 1/19/2015 - updated the smys. Was incorrectly entered as %smys.
Detailed record list
Report Received Date
2013-08-22 00:00:00
Iyear
2013
Report Number
20130284
Supplemental Number
20064
Report Type
Supplemental
Operator Id
30959
Name
The Dow Chemical Company
Operator Street Address
6723 E. Hwy 332 Bldg Bm-59
Operator City Name
Freeport
Operator State Abbreviation
TX
Operator Postal Code
77541
Local Datetime
2013-07-22 15:30:00
Location Latitude
29.04718
Location Longitude
-95.35215
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Other
Commodity Details
Pygas
Unintentional Release Bbls
0.2
Recovered Bbls
0.2
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2013-07-22 15:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2013-07-22 15:45:00
Still Shutdown Ind
Yes
On Site Datetime
2013-07-22 15:45:00
Nrc Rpt Datetime
2013-07-22 16:46:00
Nrc Rpt Num
1054720
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
The Dow Chemical Company
Segment Name
Dpl-191
Onshore State Abbreviation
Tx
Onshore Postal Code
77531
Onshore City Name
Clute
Onshore County Name
Brazoria
Designated Location
Survey Station No.
Designated Name
Ww-282
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
29
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Weld, Including Heat-Affected Zone
Pipe Diameter
10
Pipe Wall Thickness
0.218
Pipe Smys
60000
Pipe Specification
Api 5lx60
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
U.s. Steel
Pipe Coating Type
Extruded Polyehylene
Weld Subtype
Pipe Girth Weld
Installation Year
1977
Manufactured Year
1977
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
1000
Est Cost Prop Damage
30000
Est Cost Emergency
5000
Est Cost Environmental
200000
Est Cost Other
0
Prpty
236000
Accident Psig
250
Mop Psig
720
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
26244
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Leak was not deemed due to operator error or input. Line had been idle for a period of time and was being brought out of idle and into full service. No pressure spikes or surges.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Corrosive Commodity Ind
Yes
Int Microbiological Ind
Yes
Int Field Exam Basis Ind
Yes
Int Metallurgical Basis Ind
Yes
Int Other Loc Ind
Yes
Corrosion Location Details
Girth Weld
Corrosion Inhibitors
No
Corrosion Lining
No
Cleaning Dewatering
No
Corrosion Coupons
No
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Axial Recent Year
2013
Other Recent Year
2013
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2013
Hydrtst Most Rcnt Pressure
1642
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
S****** N*********
Preparer Title
Compliance Leader
Preparer Email
S***********@d**.com
Preparer Telephone
979-238-5964
Preparer Fax
979-238-0911
Prepared Date
2015-01-19 00:00:00
Authorizer Name
R*** T*****
Authorizer Telephone
979-238-4770
Authorizer Title
Process Leader
Authorizer Email
T*******@d**.com
Narrative
On july 22, 2013, the dow chemical company officially reported a leak on a pygas pipeline, dpl-191. The national response center report number for this incident is 1054720 and the railroad commission of texas incident number is 825. Low pressure hydrotesting the line confirmed that the pipeline had a pinhole leak in a girth weld. Metallurgical analysis from cut-outs taken of the line indicated that brine water constituents from the pygas storage well were a probable cause of the internal corrosion in the locally affected zone closest to the storage well (area where pinhole leak was found). Once the leak was discovered, the line was shut down, cleaned and cleared. Currently, dow is assessing the pipeline for any further corrosion or issues. The surrounding area has been properly remediated and all product has been recovered. On 1/19/2015 - updated the smys. Was incorrectly entered as %smys.
| Report Received Date | 2013-08-22 00:00:00 |
|---|---|
| Iyear | 2013 |
| Report Number | 20130284 |
| Supplemental Number | 20064 |
| Report Type | Supplemental |
| Operator Id | 30959 PHMSA Enforcement |
| Name | The Dow Chemical Company |
| Operator Street Address | 6723 E. Hwy 332 Bldg Bm-59 |
| Operator City Name | Freeport |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77541 |
| Local Datetime | 2013-07-22 15:30:00 |
| Location Latitude | 29.04718 Google Maps OpenStreetMap |
| Location Longitude | -95.35215 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Other |
| Commodity Details | Pygas |
| Unintentional Release Bbls | 0.2 |
| Recovered Bbls | 0.2 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Ground Patrol By Operator Or Its Contractor |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2013-07-22 15:30:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2013-07-22 15:45:00 |
| Still Shutdown Ind | Yes |
| On Site Datetime | 2013-07-22 15:45:00 |
| Nrc Rpt Datetime | 2013-07-22 16:46:00 |
| Nrc Rpt Num | 1054720 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | The Dow Chemical Company |
| Segment Name | Dpl-191 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 77531 |
| Onshore City Name | Clute |
| Onshore County Name | Brazoria |
| Designated Location | Survey Station No. |
| Designated Name | Ww-282 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 29 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Weld, Including Heat-Affected Zone |
| Pipe Diameter | 10 |
| Pipe Wall Thickness | 0.218 |
| Pipe Smys | 60000 |
| Pipe Specification | Api 5lx60 |
| Pipe Seam Type | Erw - High Frequency |
| Pipe Manufacturer | U.s. Steel |
| Pipe Coating Type | Extruded Polyehylene |
| Weld Subtype | Pipe Girth Weld |
| Installation Year | 1977 |
| Manufactured Year | 1977 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | Yes |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 1000 |
| Est Cost Prop Damage | 30000 |
| Est Cost Emergency | 5000 |
| Est Cost Environmental | 200000 |
| Est Cost Other | 0 |
| Prpty | 236000 |
| Accident Psig | 250 |
| Mop Psig | 720 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 26244 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | Yes |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Leak was not deemed due to operator error or input. Line had been idle for a period of time and was being brought out of idle and into full service. No pressure spikes or surges. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Localized Pitting |
| Int Corrosive Commodity Ind | Yes |
| Int Microbiological Ind | Yes |
| Int Field Exam Basis Ind | Yes |
| Int Metallurgical Basis Ind | Yes |
| Int Other Loc Ind | Yes |
| Corrosion Location Details | Girth Weld |
| Corrosion Inhibitors | No |
| Corrosion Lining | No |
| Cleaning Dewatering | No |
| Corrosion Coupons | No |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Axial Recent Year | 2013 |
| Other Recent Year | 2013 |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 2013 |
| Hydrtst Most Rcnt Pressure | 1642 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | S****** N********* |
| Preparer Title | Compliance Leader |
| Preparer Email | S***********@d**.com |
| Preparer Telephone | 979-238-5964 |
| Preparer Fax | 979-238-0911 |
| Prepared Date | 2015-01-19 00:00:00 |
| Authorizer Name | R*** T***** |
| Authorizer Telephone | 979-238-4770 |
| Authorizer Title | Process Leader |
| Authorizer Email | T*******@d**.com |
| Narrative | On july 22, 2013, the dow chemical company officially reported a leak on a pygas pipeline, dpl-191. The national response center report number for this incident is 1054720 and the railroad commission of texas incident number is 825. Low pressure hydrotesting the line confirmed that the pipeline had a pinhole leak in a girth weld. Metallurgical analysis from cut-outs taken of the line indicated that brine water constituents from the pygas storage well were a probable cause of the internal corrosion in the locally affected zone closest to the storage well (area where pinhole leak was found). Once the leak was discovered, the line was shut down, cleaned and cleared. Currently, dow is assessing the pipeline for any further corrosion or issues. The surrounding area has been properly remediated and all product has been recovered. On 1/19/2015 - updated the smys. Was incorrectly entered as %smys. |