GD incident on 2013-02-19 — MO

Operator
Missouri Gas Energy
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
1 fatality 4 injuries
Property damage (nominal)
$85,454
Incident datetime
2013-02-19 16:55
Report number
Location
MO, JACKSON
Narrative
On february 19, 2013, heartland midwest, llc, was installing cable near 910 w 48th street, kansas city, mo for time warner cable via a vermeer d9x13 series ii horizontal directional drill when it tore a hole in mge's two-inch gas main that was approximately 38 inches deep. Usic locating, inc. Performed one-call locating for the city of kansas city, mge and other underground facility owners. Usic marked the presence of one underground electrical line for the streetlights and one underground gas line about a foot to the south of the electrical line. However, there actually were two electrical lines at that location, not one, along with the gas line about a foot to the south of the two electrical lines. Heartland personnel dug one pothole between the single red broken paint line for one electrical line and the single broken yellow paint line for the gas line marked on the surface and found two conduits. Heartland concluded they had exposed the electrical line and the gas line that usic had marked. In reality, heartland had exposed two electrical conduits and had not exposed the gas main. Heartland then directed the drill to a depth about a foot below the conduits and struck the gas main. Heartland failed to extend the pothole to the depth of the planned bore where the drill could be observed passing below the conduits. The gas line was struck between 16:00 and 16:30, but heartland personnel did not notify emergency personnel until they called 911 at 16:54. Mge dispatch was notified at 16:55. In reference to part a, question 16, mge gave evacuation orders to two structures (906 and 910 w 48th street) prior to the explosion. The explosion at jj's restaurant, 910 w. 48th street, kansas city, mo, occurred at 18:02. The two-inch valve at the nw corner of 48th and roanoke was closed at 19:20. The two-inch gas main was pinched off at the se corner of 48th and belleview at 20:00. After the gas flow was stopped, the gas main on 48th street was cut and capped at the ne corner of 48th and belleview and just west of the two-inch valve at the nw corner of 48th and roanoke. Then, the gas main on belleview was re-energized to allow gas flow to customers on belleview between 48th and 47th streets. The gas main on 48th street between belleview and roanoke is still inactive. One fatality and multiple injuries resulted, including mge's first responder, and employees of heartland and jj's restaurant. There was significant property damage, but the total estimated property damage is unknown at this time, in part because litigation continues involving three buildings in the vicinity and one issue in each case is the extent of the damages resulting from the explosion. Mge had six employees on site at the time of the explosion. As mge was unable to complete a full investigation on the night of the incident to determine whether any of its on-site employees contributed to the incident, five of the six employees were sent to the hospital later that evening for DOT post-accident drug and alcohol testing. The hospital was instructed to administer DOT post-accident drug and alcohol testing for all five employees. Drug and alcohol tests were administered to four of the employees, with no positive results. A drug test was administered to the fifth employee with no positive results. The hospital was instructed to administer an alcohol test to the fifth employee, but did not. The sixth employee, mge's first responder, was tested for alcohol and drugs after the incident in the course of the treatment for his injuries at st. Luke's hospital, and that the results were negative. Mge does not believe its employees' performance contributed to the incident.
Detailed record list
Occurred At
2013-02-19 16:55:00
Year
2013
Report Received Date
2013-03-21 00:00:00
Iyear
2013.0
Report Number
20130031.0
Supplemental Number
30415.0
Report Type
Supplemental
Operator Id
Name
Missouri Gas Energy
Operator Street Address
700 Market Street
Operator City Name
Saint Louis
Operator State Abbreviation
MO
Operator Postal Code
63101
Local Datetime
2013-02-19 18:02:00
Location Street Address
Near 910 W 48th St
Location City Name
Kansas City
Location County Name
Jackson
Location State Abbreviation
MO
Location Postal Code
64112
Location Latitude
Location Longitude
Nrc Rpt Datetime
2013-02-19 18:57:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
180.0
Fatality Ind
Yes
Num Emp Fatalities
0
Num Contr Fatalities
0
Num Er Fatalities
0
Num Worker Fatalities
0
Num Gp Fatalities
1
Fatal
1
Injury Ind
Yes
Num Emp Injuries
1
Num Contr Injuries
0
Num Er Injuries
0
Num Worker Injuries
2
Num Gp Injuries
1
Injure
4
Ignite Ind
Yes
Explode Ind
Yes
Num Pub Evacuated
2.0
Incident Identified Datetime
2013-02-19 16:55:00
On Site Datetime
2013-02-19 17:16:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
38.0
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2000.0
Pipe Diameter
2.0
Pipe Specification
Astm. D2513
Pipe Manufacturer
Performance Pipe
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
1.0
Puncture Circum
1.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
19566000.0
Est Cost Prop Damage
85454.0
Est Cost Emergency
75587.0
Est Cost Other
0.0
Est Cost Unintentional Release
1000.0
Prpty
19728041.0
Commercial Affected
2.0
Industrial Affected
0.0
Residences Affected
0.0
Accident Psig
25.0
Normal Psig
25.0
Mop Psig
58.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
Yes
Num Employees Tested
5
Num Employees Failed
0
Contractor Drug Test Ind
Yes
Num Contractors Tested
1
Num Contractors Failed
0
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
Notify Cga Dirt
No
Public Row Ind
Yes
Public Subtype
City Street
Excavator Type
Contractor
Excavator Equipment
Directional Drilling
Work Performed
Cable Tv
One Call Notified Ind
Yes
One Call Ticket Num
130370903
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
Yes
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Locator Error
Preparer Name
R**** W*****
Preparer Title
Manager Pipeline Safety And Compliance
Preparer Email
R***********@s**********.com
Preparer Telephone
205-326-2987
Authorizer Name
C**** R* H********
Authorizer Title
Vice President Operations Services
Authorizer Telephone
314-349-2972
Authorizer Email
C**************@t**************.com
Narrative
On february 19, 2013, heartland midwest, llc, was installing cable near 910 w 48th street, kansas city, mo for time warner cable via a vermeer d9x13 series ii horizontal directional drill when it tore a hole in mge's two-inch gas main that was approximately 38 inches deep. Usic locating, inc. Performed one-call locating for the city of kansas city, mge and other underground facility owners. Usic marked the presence of one underground electrical line for the streetlights and one underground gas line about a foot to the south of the electrical line. However, there actually were two electrical lines at that location, not one, along with the gas line about a foot to the south of the two electrical lines. Heartland personnel dug one pothole between the single red broken paint line for one electrical line and the single broken yellow paint line for the gas line marked on the surface and found two conduits. Heartland concluded they had exposed the electrical line and the gas line that usic had marked. In reality, heartland had exposed two electrical conduits and had not exposed the gas main. Heartland then directed the drill to a depth about a foot below the conduits and struck the gas main. Heartland failed to extend the pothole to the depth of the planned bore where the drill could be observed passing below the conduits. The gas line was struck between 16:00 and 16:30, but heartland personnel did not notify emergency personnel until they called 911 at 16:54. Mge dispatch was notified at 16:55. In reference to part a, question 16, mge gave evacuation orders to two structures (906 and 910 w 48th street) prior to the explosion. The explosion at jj's restaurant, 910 w. 48th street, kansas city, mo, occurred at 18:02. The two-inch valve at the nw corner of 48th and roanoke was closed at 19:20. The two-inch gas main was pinched off at the se corner of 48th and belleview at 20:00. After the gas flow was stopped, the gas main on 48th street was cut and capped at the ne corner of 48th and belleview and just west of the two-inch valve at the nw corner of 48th and roanoke. Then, the gas main on belleview was re-energized to allow gas flow to customers on belleview between 48th and 47th streets. The gas main on 48th street between belleview and roanoke is still inactive. One fatality and multiple injuries resulted, including mge's first responder, and employees of heartland and jj's restaurant. There was significant property damage, but the total estimated property damage is unknown at this time, in part because litigation continues involving three buildings in the vicinity and one issue in each case is the extent of the damages resulting from the explosion. Mge had six employees on site at the time of the explosion. As mge was unable to complete a full investigation on the night of the incident to determine whether any of its on-site employees contributed to the incident, five of the six employees were sent to the hospital later that evening for DOT post-accident drug and alcohol testing. The hospital was instructed to administer DOT post-accident drug and alcohol testing for all five employees. Drug and alcohol tests were administered to four of the employees, with no positive results. A drug test was administered to the fifth employee with no positive results. The hospital was instructed to administer an alcohol test to the fifth employee, but did not. The sixth employee, mge's first responder, was tested for alcohol and drugs after the incident in the course of the treatment for his injuries at st. Luke's hospital, and that the results were negative. Mge does not believe its employees' performance contributed to the incident.
Occurred At 2013-02-19 16:55:00
Year 2013
Report Received Date 2013-03-21 00:00:00
Iyear 2013.0
Report Number 20130031.0
Supplemental Number 30415.0
Report Type Supplemental
Operator Id 30769 PHMSA Enforcement
Name Missouri Gas Energy
Operator Street Address 700 Market Street
Operator City Name Saint Louis
Operator State Abbreviation MO
Operator Postal Code 63101
Local Datetime 2013-02-19 18:02:00
Location Street Address Near 910 W 48th St
Location City Name Kansas City
Location County Name Jackson
Location State Abbreviation MO
Location Postal Code 64112
Location Latitude 39.040734 Google Maps OpenStreetMap
Location Longitude -94.598063 Google Maps OpenStreetMap
Nrc Rpt Datetime 2013-02-19 18:57:00
Nrc Rpt Num 1038907 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 180.0
Fatality Ind Yes
Num Emp Fatalities 0
Num Contr Fatalities 0
Num Er Fatalities 0
Num Worker Fatalities 0
Num Gp Fatalities 1
Fatal 1
Injury Ind Yes
Num Emp Injuries 1
Num Contr Injuries 0
Num Er Injuries 0
Num Worker Injuries 2
Num Gp Injuries 1
Injure 4
Ignite Ind Yes
Explode Ind Yes
Num Pub Evacuated 2.0
Incident Identified Datetime 2013-02-19 16:55:00
On Site Datetime 2013-02-19 17:16:00
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Under Pavement
Depth Of Cover 38.0
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Main
Installation Year 2000.0
Pipe Diameter 2.0
Pipe Specification Astm. D2513
Pipe Manufacturer Performance Pipe
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11
Material Pe Pipe Code 2406
Release Type Mechanical Puncture
Puncture Axial 1.0
Puncture Circum 1.5
Class Location Type Class 3 Location
Est Cost Oper Paid 19566000.0
Est Cost Prop Damage 85454.0
Est Cost Emergency 75587.0
Est Cost Other 0.0
Est Cost Unintentional Release 1000.0
Prpty 19728041.0
Commercial Affected 2.0
Industrial Affected 0.0
Residences Affected 0.0
Accident Psig 25.0
Normal Psig 25.0
Mop Psig 58.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind Yes
Num Employees Tested 5
Num Employees Failed 0
Contractor Drug Test Ind Yes
Num Contractors Tested 1
Num Contractors Failed 0
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
Notify Cga Dirt No
Public Row Ind Yes
Public Subtype City Street
Excavator Type Contractor
Excavator Equipment Directional Drilling
Work Performed Cable Tv
One Call Notified Ind Yes
One Call Ticket Num 130370903
Locator Type Contract Locator
Visible Marks Yes
Service Interruption Yes
Root Cause Category Locating Issue
Root Cause Type Facility Not Marked Due To Locator Error
Preparer Name R**** W*****
Preparer Title Manager Pipeline Safety And Compliance
Preparer Email R***********@s**********.com
Preparer Telephone 205-326-2987
Authorizer Name C**** R* H********
Authorizer Title Vice President Operations Services
Authorizer Telephone 314-349-2972
Authorizer Email C**************@t**************.com
Narrative On february 19, 2013, heartland midwest, llc, was installing cable near 910 w 48th street, kansas city, mo for time warner cable via a vermeer d9x13 series ii horizontal directional drill when it tore a hole in mge's two-inch gas main that was approximately 38 inches deep. Usic locating, inc. Performed one-call locating for the city of kansas city, mge and other underground facility owners. Usic marked the presence of one underground electrical line for the streetlights and one underground gas line about a foot to the south of the electrical line. However, there actually were two electrical lines at that location, not one, along with the gas line about a foot to the south of the two electrical lines. Heartland personnel dug one pothole between the single red broken paint line for one electrical line and the single broken yellow paint line for the gas line marked on the surface and found two conduits. Heartland concluded they had exposed the electrical line and the gas line that usic had marked. In reality, heartland had exposed two electrical conduits and had not exposed the gas main. Heartland then directed the drill to a depth about a foot below the conduits and struck the gas main. Heartland failed to extend the pothole to the depth of the planned bore where the drill could be observed passing below the conduits. The gas line was struck between 16:00 and 16:30, but heartland personnel did not notify emergency personnel until they called 911 at 16:54. Mge dispatch was notified at 16:55. In reference to part a, question 16, mge gave evacuation orders to two structures (906 and 910 w 48th street) prior to the explosion. The explosion at jj's restaurant, 910 w. 48th street, kansas city, mo, occurred at 18:02. The two-inch valve at the nw corner of 48th and roanoke was closed at 19:20. The two-inch gas main was pinched off at the se corner of 48th and belleview at 20:00. After the gas flow was stopped, the gas main on 48th street was cut and capped at the ne corner of 48th and belleview and just west of the two-inch valve at the nw corner of 48th and roanoke. Then, the gas main on belleview was re-energized to allow gas flow to customers on belleview between 48th and 47th streets. The gas main on 48th street between belleview and roanoke is still inactive. One fatality and multiple injuries resulted, including mge's first responder, and employees of heartland and jj's restaurant. There was significant property damage, but the total estimated property damage is unknown at this time, in part because litigation continues involving three buildings in the vicinity and one issue in each case is the extent of the damages resulting from the explosion. Mge had six employees on site at the time of the explosion. As mge was unable to complete a full investigation on the night of the incident to determine whether any of its on-site employees contributed to the incident, five of the six employees were sent to the hospital later that evening for DOT post-accident drug and alcohol testing. The hospital was instructed to administer DOT post-accident drug and alcohol testing for all five employees. Drug and alcohol tests were administered to four of the employees, with no positive results. A drug test was administered to the fifth employee with no positive results. The hospital was instructed to administer an alcohol test to the fifth employee, but did not. The sixth employee, mge's first responder, was tested for alcohol and drugs after the incident in the course of the treatment for his injuries at st. Luke's hospital, and that the results were negative. Mge does not believe its employees' performance contributed to the incident.

All rights reserved. Copyright © by ClearPHMSA