Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2012-09-18 — TX
Operator
Enterprise Crude Pipeline Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$3,000
Incident datetime
2012-09-18 10:18
Report number
Location
TX
Narrative
Air patrol discovered a stain on our c18 8-inch line south of olney texas. Crews responded to the site and reported an approximately 1 barrel release. Crews placed a clamp on the line and started cleanup. The pit in the line was at approximately the 7 o'clock position and thought to be external corrosion. The line was shut down and isolated and the leak is contained. No waterways were affected and no road closures reported.
Detailed record list
Report Received Date
2012-10-17 00:00:00
Iyear
2012
Report Number
20120297
Supplemental Number
16961
Report Type
Original Final
Operator Id
30829
Name
Enterprise Crude Pipeline Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2012-09-18 10:18:00
Location Latitude
33.33278
Location Longitude
-98.72257
Commodity Released Type
Crude Oil
Unintentional Release Bbls
1
Intentional Release Bbls
0
Recovered Bbls
0.25
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Ignite Ind
No
Explode Ind
No
Pipe Fac Name
C18
Onshore State Abbreviation
Tx
Onshore Postal Code
76374
Onshore City Name
Olney
Onshore County Name
Young
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Release Type
Leak
Leak Type
Pinhole
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
100
Est Cost Prop Damage
3000
Est Cost Emergency
0
Est Cost Environmental
7500
Est Cost Other
0
Prpty
10600
Pipeline Function
> 20% Smys Regulated Transmission
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Preparer Name
C********** H****
Preparer Email
C******@e****.com
Preparer Telephone
713-381-6304
Prepared Date
2012-10-17 00:00:00
Authorizer Name
C********** H****
Authorizer Telephone
713-381-6304
Authorizer Title
Pipeline Compliance Engineer
Authorizer Email
C******@e****.com
Narrative
Air patrol discovered a stain on our c18 8-inch line south of olney texas. Crews responded to the site and reported an approximately 1 barrel release. Crews placed a clamp on the line and started cleanup. The pit in the line was at approximately the 7 o'clock position and thought to be external corrosion. The line was shut down and isolated and the leak is contained. No waterways were affected and no road closures reported.
| Report Received Date | 2012-10-17 00:00:00 |
|---|---|
| Iyear | 2012 |
| Report Number | 20120297 |
| Supplemental Number | 16961 |
| Report Type | Original Final |
| Operator Id | 30829 PHMSA Enforcement |
| Name | Enterprise Crude Pipeline Llc |
| Operator Street Address | 1100 Louisiana Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2012-09-18 10:18:00 |
| Location Latitude | 33.33278 Google Maps OpenStreetMap |
| Location Longitude | -98.72257 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 1 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0.25 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Ignite Ind | No |
| Explode Ind | No |
| Pipe Fac Name | C18 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 76374 |
| Onshore City Name | Olney |
| Onshore County Name | Young |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Release Type | Leak |
| Leak Type | Pinhole |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 100 |
| Est Cost Prop Damage | 3000 |
| Est Cost Emergency | 0 |
| Est Cost Environmental | 7500 |
| Est Cost Other | 0 |
| Prpty | 10600 |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Preparer Name | C********** H**** |
| Preparer Email | C******@e****.com |
| Preparer Telephone | 713-381-6304 |
| Prepared Date | 2012-10-17 00:00:00 |
| Authorizer Name | C********** H**** |
| Authorizer Telephone | 713-381-6304 |
| Authorizer Title | Pipeline Compliance Engineer |
| Authorizer Email | C******@e****.com |
| Narrative | Air patrol discovered a stain on our c18 8-inch line south of olney texas. Crews responded to the site and reported an approximately 1 barrel release. Crews placed a clamp on the line and started cleanup. The pit in the line was at approximately the 7 o'clock position and thought to be external corrosion. The line was shut down and isolated and the leak is contained. No waterways were affected and no road closures reported. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA