Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2012-07-02 — TX
Operator
Centurion Pipeline L.p.
Cause
Miscellaneous Root Causes
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$90,000
Incident datetime
2012-07-02 18:05
Report number
Location
TX
Narrative
The landowner was deep breaking his field and struck centurion's #1 16" mainline. The strike occurred in an area where it appears there has been possible rain water runoff causing some soil erosion. This may have lessened the pipeline cover in that particular spot. The damaged pipeline section was cut out and replaced with new pipe. The affected area was remediated, reseeded, irrigated and a pipeline depth profile was also completed. The entire line on his property was flagged enabling the tractor driver to stop short of the flagged lines, lift and then continue. Centurion commissioned a line lowering project that was completed in november, 2013, thereby increasing the "cover" for the pipeline in the accident area and other portions of the pipeline in that part of oklahoma.
Detailed record list
Report Received Date
2012-07-17 00:00:00
Iyear
2012
Report Number
20120217
Supplemental Number
21513
Report Type
Supplemental Final
Operator Id
31888
Name
Centurion Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2012-07-02 18:05:00
Location Latitude
34.84251
Location Longitude
-99.13711
Commodity Released Type
Crude Oil
Unintentional Release Bbls
211
Recovered Bbls
10
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Notification From Third Pary That Caused The Accident
Incident Identified Datetime
2012-07-02 18:05:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Pipeline Idle At Time Of Accident Maintained Idle
On Site Datetime
2012-07-02 19:10:00
Nrc Rpt Datetime
2012-07-02 19:37:00
Nrc Rpt Num
1016538
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Wcs Sour Crude Pipeline
Segment Name
#1 Twin 16" Mainline
Onshore State Abbreviation
Ok
Onshore Postal Code
73564
Onshore City Name
Roosevelt
Onshore County Name
Kiowa
Designated Location
Milepost/valve Station
Designated Name
168
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
10
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
16
Pipe Wall Thickness
0.25
Pipe Smys
35000
Pipe Specification
Not Determined
Pipe Seam Type
Seamless
Pipe Manufacturer
Youngstown
Pipe Coating Type
Coal Tar
Installation Year
1960
Manufactured Year
1948
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
1
Puncture Circum
1
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Vegetation Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
8000
Est Cost Gas Released
19000
Est Cost Prop Damage
90000
Est Cost Emergency
50000
Est Cost Environmental
136000
Est Cost Other
0
Prpty
303000
Accident Psig
301
Mop Psig
794
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
16262
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Control operation did not contribute to failure or magnitude, as notification was promply recieved from landowner
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
No
Notify Cga Dirt
Yes
Pipeline Easement Row Ind
Yes
Excavator Type
Farmer
Excavator Equipment
Farm Equipment
Work Performed
Agriculture
One Call Notified Ind
No
Locator Type
Unknown/other
Visible Marks
Unknown/other
Root Cause Category
Miscellaneous Root Causes
Root Cause Type
Root Cause Not Listed (Comment Required)
Root Cause Type Other
Agricultural Excavator Exempt From One-Call Rule.
Preparer Name
A***** O****
Preparer Title
Hes Specialist
Preparer Email
A***********@o**.com
Preparer Telephone
325-573-3589
Preparer Fax
325-573-0244
Prepared Date
2016-07-11 00:00:00
Authorizer Name
O* H* C*********
Authorizer Telephone
713-497-2016
Authorizer Title
Director Pipeline Compliance
Authorizer Email
C***************@o**.com
Narrative
The landowner was deep breaking his field and struck centurion's #1 16" mainline. The strike occurred in an area where it appears there has been possible rain water runoff causing some soil erosion. This may have lessened the pipeline cover in that particular spot. The damaged pipeline section was cut out and replaced with new pipe. The affected area was remediated, reseeded, irrigated and a pipeline depth profile was also completed. The entire line on his property was flagged enabling the tractor driver to stop short of the flagged lines, lift and then continue. Centurion commissioned a line lowering project that was completed in november, 2013, thereby increasing the "cover" for the pipeline in the accident area and other portions of the pipeline in that part of oklahoma.
| Report Received Date | 2012-07-17 00:00:00 |
|---|---|
| Iyear | 2012 |
| Report Number | 20120217 |
| Supplemental Number | 21513 |
| Report Type | Supplemental Final |
| Operator Id | 31888 PHMSA Enforcement |
| Name | Centurion Pipeline L.p. |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2012-07-02 18:05:00 |
| Location Latitude | 34.84251 Google Maps OpenStreetMap |
| Location Longitude | -99.13711 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 211 |
| Recovered Bbls | 10 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Other |
| Accident Details | Notification From Third Pary That Caused The Accident |
| Incident Identified Datetime | 2012-07-02 18:05:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Pipeline Idle At Time Of Accident Maintained Idle |
| On Site Datetime | 2012-07-02 19:10:00 |
| Nrc Rpt Datetime | 2012-07-02 19:37:00 |
| Nrc Rpt Num | 1016538 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Valve Type Ind | Remotely Controlled |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Wcs Sour Crude Pipeline |
| Segment Name | #1 Twin 16" Mainline |
| Onshore State Abbreviation | Ok |
| Onshore Postal Code | 73564 |
| Onshore City Name | Roosevelt |
| Onshore County Name | Kiowa |
| Designated Location | Milepost/valve Station |
| Designated Name | 168 |
| Federal | No |
| Location Type | Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 10 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 16 |
| Pipe Wall Thickness | 0.25 |
| Pipe Smys | 35000 |
| Pipe Specification | Not Determined |
| Pipe Seam Type | Seamless |
| Pipe Manufacturer | Youngstown |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1960 |
| Manufactured Year | 1948 |
| Material Involved | Carbon Steel |
| Release Type | Mechanical Puncture |
| Puncture Axial | 1 |
| Puncture Circum | 1 |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Vegetation Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 8000 |
| Est Cost Gas Released | 19000 |
| Est Cost Prop Damage | 90000 |
| Est Cost Emergency | 50000 |
| Est Cost Environmental | 136000 |
| Est Cost Other | 0 |
| Prpty | 303000 |
| Accident Psig | 301 |
| Mop Psig | 794 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 16262 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | Yes |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Control operation did not contribute to failure or magnitude, as notification was promply recieved from landowner |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | No |
| Notify Cga Dirt | Yes |
| Pipeline Easement Row Ind | Yes |
| Excavator Type | Farmer |
| Excavator Equipment | Farm Equipment |
| Work Performed | Agriculture |
| One Call Notified Ind | No |
| Locator Type | Unknown/other |
| Visible Marks | Unknown/other |
| Root Cause Category | Miscellaneous Root Causes |
| Root Cause Type | Root Cause Not Listed (Comment Required) |
| Root Cause Type Other | Agricultural Excavator Exempt From One-Call Rule. |
| Preparer Name | A***** O**** |
| Preparer Title | Hes Specialist |
| Preparer Email | A***********@o**.com |
| Preparer Telephone | 325-573-3589 |
| Preparer Fax | 325-573-0244 |
| Prepared Date | 2016-07-11 00:00:00 |
| Authorizer Name | O* H* C********* |
| Authorizer Telephone | 713-497-2016 |
| Authorizer Title | Director Pipeline Compliance |
| Authorizer Email | C***************@o**.com |
| Narrative | The landowner was deep breaking his field and struck centurion's #1 16" mainline. The strike occurred in an area where it appears there has been possible rain water runoff causing some soil erosion. This may have lessened the pipeline cover in that particular spot. The damaged pipeline section was cut out and replaced with new pipe. The affected area was remediated, reseeded, irrigated and a pipeline depth profile was also completed. The entire line on his property was flagged enabling the tractor driver to stop short of the flagged lines, lift and then continue. Centurion commissioned a line lowering project that was completed in november, 2013, thereby increasing the "cover" for the pipeline in the accident area and other portions of the pipeline in that part of oklahoma. |
External Resources