Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2012-06-15 — TX
Operator
Rose Rock Midstream L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$6,020
Incident datetime
2012-06-15 15:50
Report number
Location
TX
Narrative
Landowner notified el dorado fire department of release. El dorado fire department notified rose rock midstream, lp. Line was immediately shut down and company personnel dispatched to site along with vaccuum trucks and backhoe. Flume dam was installed to contain oil in wash where it had collected. All oil substantially collected within 10 hours. 185 feet of pipe was replaced with 6 5/8" od x 0.280" wt erw API x42/x52 steel pipe coated with 14 to 16 mils fbe. The pipe was hydrostatically tested for 4 hours to a minimum pressure of 1865 psi. Work was completed on monday, june 18, and line re-started at 08:10 on tuesday, june 19. Pipe was sent to det norske veritas (u.S.A) inc. In dublin, ohio for metallurgical analysis and failure cause determination. The analysis determined the most likely cause of the corrosion was microbiologically influenced corrosion (mic).
Detailed record list
Report Received Date
2012-07-02 00:00:00
Iyear
2012
Report Number
20120202
Supplemental Number
17135
Report Type
Supplemental Final
Operator Id
31476
Name
Rose Rock Midstream L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2012-06-15 15:50:00
Location Latitude
37.7958
Location Longitude
-96.72309
Commodity Released Type
Crude Oil
Unintentional Release Bbls
60
Intentional Release Bbls
0
Recovered Bbls
58
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2012-06-15 15:50:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2012-06-15 16:00:00
Restart Datetime
2012-06-19 08:10:00
On Site Datetime
2012-06-15 16:20:00
Nrc Rpt Datetime
2012-06-15 17:40:00
Nrc Rpt Num
1014727
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Burkett Discharge
Segment Name
Burkett Discharge
Onshore State Abbreviation
Ks
Onshore Postal Code
67042
Onshore City Name
El Dorado
Onshore County Name
Butler
Designated Location
Milepost/valve Station
Designated Name
10.7
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
38
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
6.625
Pipe Wall Thickness
0.28
Pipe Smys
24000
Pipe Specification
Unknown
Pipe Seam Type
Erw � Unknown Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Installation Year
1954
Manufactured Year
1954
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
58
Rel Water Name
Unnamed Wash
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
2500
Est Cost Gas Released
200
Est Cost Prop Damage
6020
Est Cost Emergency
10500
Est Cost Environmental
8500
Est Cost Other
16000
Est Cost Other Details
Cost Of Metallurgical Analysis.
Prpty
43720
Accident Psig
201
Mop Psig
280
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
61047
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Microbiological Ind
Yes
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
Yes
Corrosion Coupons
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
E**** C***
Preparer Title
Director Corporate Ehs
Preparer Email
E****@s***********.com
Preparer Telephone
9186403394
Preparer Fax
9185247243
Prepared Date
2012-12-21 00:00:00
Authorizer Name
E**** C***
Authorizer Telephone
9186403384
Authorizer Title
Director Corporate Ehs
Authorizer Email
E****@s***********.com
Narrative
Landowner notified el dorado fire department of release. El dorado fire department notified rose rock midstream, lp. Line was immediately shut down and company personnel dispatched to site along with vaccuum trucks and backhoe. Flume dam was installed to contain oil in wash where it had collected. All oil substantially collected within 10 hours. 185 feet of pipe was replaced with 6 5/8" od x 0.280" wt erw API x42/x52 steel pipe coated with 14 to 16 mils fbe. The pipe was hydrostatically tested for 4 hours to a minimum pressure of 1865 psi. Work was completed on monday, june 18, and line re-started at 08:10 on tuesday, june 19. Pipe was sent to det norske veritas (u.S.A) inc. In dublin, ohio for metallurgical analysis and failure cause determination. The analysis determined the most likely cause of the corrosion was microbiologically influenced corrosion (mic).
| Report Received Date | 2012-07-02 00:00:00 |
|---|---|
| Iyear | 2012 |
| Report Number | 20120202 |
| Supplemental Number | 17135 |
| Report Type | Supplemental Final |
| Operator Id | 31476 PHMSA Enforcement |
| Name | Rose Rock Midstream L.p. |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2012-06-15 15:50:00 |
| Location Latitude | 37.7958 Google Maps OpenStreetMap |
| Location Longitude | -96.72309 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 60 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 58 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Public |
| Incident Identified Datetime | 2012-06-15 15:50:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2012-06-15 16:00:00 |
| Restart Datetime | 2012-06-19 08:10:00 |
| On Site Datetime | 2012-06-15 16:20:00 |
| Nrc Rpt Datetime | 2012-06-15 17:40:00 |
| Nrc Rpt Num | 1014727 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Burkett Discharge |
| Segment Name | Burkett Discharge |
| Onshore State Abbreviation | Ks |
| Onshore Postal Code | 67042 |
| Onshore City Name | El Dorado |
| Onshore County Name | Butler |
| Designated Location | Milepost/valve Station |
| Designated Name | 10.7 |
| Federal | No |
| Location Type | Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 38 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 6.625 |
| Pipe Wall Thickness | 0.28 |
| Pipe Smys | 24000 |
| Pipe Specification | Unknown |
| Pipe Seam Type | Erw � Unknown Frequency |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1954 |
| Manufactured Year | 1954 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | Yes |
| Surface Contam Ind | Yes |
| Amount Released | 58 |
| Rel Water Name | Unnamed Wash |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 2500 |
| Est Cost Gas Released | 200 |
| Est Cost Prop Damage | 6020 |
| Est Cost Emergency | 10500 |
| Est Cost Environmental | 8500 |
| Est Cost Other | 16000 |
| Est Cost Other Details | Cost Of Metallurgical Analysis. |
| Prpty | 43720 |
| Accident Psig | 201 |
| Mop Psig | 280 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 61047 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Localized Pitting |
| Int Microbiological Ind | Yes |
| Int Field Exam Basis Ind | Yes |
| Int Low Point Pipe Loc Ind | Yes |
| Corrosion Inhibitors | Yes |
| Corrosion Lining | No |
| Cleaning Dewatering | Yes |
| Corrosion Coupons | Yes |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | E**** C*** |
| Preparer Title | Director Corporate Ehs |
| Preparer Email | E****@s***********.com |
| Preparer Telephone | 9186403394 |
| Preparer Fax | 9185247243 |
| Prepared Date | 2012-12-21 00:00:00 |
| Authorizer Name | E**** C*** |
| Authorizer Telephone | 9186403384 |
| Authorizer Title | Director Corporate Ehs |
| Authorizer Email | E****@s***********.com |
| Narrative | Landowner notified el dorado fire department of release. El dorado fire department notified rose rock midstream, lp. Line was immediately shut down and company personnel dispatched to site along with vaccuum trucks and backhoe. Flume dam was installed to contain oil in wash where it had collected. All oil substantially collected within 10 hours. 185 feet of pipe was replaced with 6 5/8" od x 0.280" wt erw API x42/x52 steel pipe coated with 14 to 16 mils fbe. The pipe was hydrostatically tested for 4 hours to a minimum pressure of 1865 psi. Work was completed on monday, june 18, and line re-started at 08:10 on tuesday, june 19. Pipe was sent to det norske veritas (u.S.A) inc. In dublin, ohio for metallurgical analysis and failure cause determination. The analysis determined the most likely cause of the corrosion was microbiologically influenced corrosion (mic). |
External Resources
PHMSA pipeline safety insights.
Product