Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2011-11-16 — TX
Operator
Enterprise Crude Pipeline Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$37,731
Incident datetime
2011-11-16 11:20
Report number
Location
TX
Narrative
An enbridge employee notified enterprise of a leak on the 8-inch crude line located on enbridge property. The line was immediately shutdown and cleanup actions implemented. Sunoco was in the process of delivering 43,700 barrels of crude oil to the cushing east facility when the release was discovered. A hydroexcavator was used to expose the pipeline and locate the source of the leak. A temporary clamp was installed to ensure no additional product was leaked and until a plidco clamp could be located and installed. The delivery resumed after the plidco clamp was installed with pumping restricted to daylight operations only. The recommendation is that the existing delivery line from the sunoco meter bank to the leak site be pigged, purged, filled with nitrogen and abandoned in place; isolating the line to the west facility fabricate and install a new, above ground 8-inch line from the sunoco meter bank to the sunoco delivery manifold that supplies the enterprise east facility. All future sunoco deliveries will be received into the cushing east facility.
Detailed record list
Report Received Date
2011-12-09 00:00:00
Iyear
2011
Report Number
20110443
Supplemental Number
16738
Report Type
Supplemental Final
Operator Id
30829
Name
Enterprise Crude Pipeline Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2011-11-16 11:20:00
Location Latitude
35.94085
Location Longitude
-96.7502
Commodity Released Type
Crude Oil
Unintentional Release Bbls
140
Recovered Bbls
85
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Third Party That Caused The Accident
Incident Identified Datetime
2011-11-16 11:20:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-11-16 11:45:00
Still Shutdown Ind
Yes
On Site Datetime
2011-11-16 11:45:00
Nrc Rpt Datetime
2011-11-16 13:34:00
Nrc Rpt Num
995709
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Pipe Fac Name
C78
Segment Name
Cushing West (Koch) To Cushing East
Onshore State Abbreviation
Ok
Onshore Postal Code
74023
Onshore City Name
Cushing
Onshore County Name
Lincoln
Designated Location
Milepost/valve Station
Designated Name
Mp 08+80
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8.625
Pipe Wall Thickness
0.28
Pipe Smys
24000
Pipe Specification
Unk
Pipe Seam Type
Erw � Unknown Frequency
Pipe Manufacturer
Unk/ Yr - Unk
Pipe Coating Type
Fusion Bonded Epoxy(Fbe)
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
5225
Est Cost Prop Damage
37731
Est Cost Emergency
10000
Est Cost Environmental
58695
Est Cost Other
0
Prpty
111651
Accident Psig
75
Mop Psig
150
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
2500
Internal Inspection Ind
No
Other Inspection Ind
Yes
Internal Inspection Details
Dead Leg On The Piping Where Corrosion Occured.
Operation Complications Ind
Yes
Low Flow Ind
Yes
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Not Cut Open
Int Microbiological Ind
Yes
Int Field Exam Basis Ind
Yes
Int Other Basis Ind
Yes
Int Corrosion Basis Details
Based On Past Experience With This Commodity And Dead Legs In Crude Service.
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
No
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1996
Hydrtst Most Rcnt Pressure
356
Preparer Name
C********** H****
Prepared Date
2012-07-02 00:00:00
Authorizer Name
C********** H****
Authorizer Telephone
713-381-6304
Authorizer Title
Pipeline Compliance Specialist
Authorizer Email
C******@e****.com
Narrative
An enbridge employee notified enterprise of a leak on the 8-inch crude line located on enbridge property. The line was immediately shutdown and cleanup actions implemented. Sunoco was in the process of delivering 43,700 barrels of crude oil to the cushing east facility when the release was discovered. A hydroexcavator was used to expose the pipeline and locate the source of the leak. A temporary clamp was installed to ensure no additional product was leaked and until a plidco clamp could be located and installed. The delivery resumed after the plidco clamp was installed with pumping restricted to daylight operations only. The recommendation is that the existing delivery line from the sunoco meter bank to the leak site be pigged, purged, filled with nitrogen and abandoned in place; isolating the line to the west facility fabricate and install a new, above ground 8-inch line from the sunoco meter bank to the sunoco delivery manifold that supplies the enterprise east facility. All future sunoco deliveries will be received into the cushing east facility.
| Report Received Date | 2011-12-09 00:00:00 |
|---|---|
| Iyear | 2011 |
| Report Number | 20110443 |
| Supplemental Number | 16738 |
| Report Type | Supplemental Final |
| Operator Id | 30829 PHMSA Enforcement |
| Name | Enterprise Crude Pipeline Llc |
| Operator Street Address | 1100 Louisiana Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2011-11-16 11:20:00 |
| Location Latitude | 35.94085 Google Maps OpenStreetMap |
| Location Longitude | -96.7502 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 140 |
| Recovered Bbls | 85 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Third Party That Caused The Accident |
| Incident Identified Datetime | 2011-11-16 11:20:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2011-11-16 11:45:00 |
| Still Shutdown Ind | Yes |
| On Site Datetime | 2011-11-16 11:45:00 |
| Nrc Rpt Datetime | 2011-11-16 13:34:00 |
| Nrc Rpt Num | 995709 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Manual |
| Downstream Valve Type Ind | Manual |
| Pipe Fac Name | C78 |
| Segment Name | Cushing West (Koch) To Cushing East |
| Onshore State Abbreviation | Ok |
| Onshore Postal Code | 74023 |
| Onshore City Name | Cushing |
| Onshore County Name | Lincoln |
| Designated Location | Milepost/valve Station |
| Designated Name | Mp 08+80 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 8.625 |
| Pipe Wall Thickness | 0.28 |
| Pipe Smys | 24000 |
| Pipe Specification | Unk |
| Pipe Seam Type | Erw � Unknown Frequency |
| Pipe Manufacturer | Unk/ Yr - Unk |
| Pipe Coating Type | Fusion Bonded Epoxy(Fbe) |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 5225 |
| Est Cost Prop Damage | 37731 |
| Est Cost Emergency | 10000 |
| Est Cost Environmental | 58695 |
| Est Cost Other | 0 |
| Prpty | 111651 |
| Accident Psig | 75 |
| Mop Psig | 150 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 2500 |
| Internal Inspection Ind | No |
| Other Inspection Ind | Yes |
| Internal Inspection Details | Dead Leg On The Piping Where Corrosion Occured. |
| Operation Complications Ind | Yes |
| Low Flow Ind | Yes |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the accident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Not Cut Open |
| Int Microbiological Ind | Yes |
| Int Field Exam Basis Ind | Yes |
| Int Other Basis Ind | Yes |
| Int Corrosion Basis Details | Based On Past Experience With This Commodity And Dead Legs In Crude Service. |
| Int Low Point Pipe Loc Ind | Yes |
| Corrosion Inhibitors | No |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 1996 |
| Hydrtst Most Rcnt Pressure | 356 |
| Preparer Name | C********** H**** |
| Prepared Date | 2012-07-02 00:00:00 |
| Authorizer Name | C********** H**** |
| Authorizer Telephone | 713-381-6304 |
| Authorizer Title | Pipeline Compliance Specialist |
| Authorizer Email | C******@e****.com |
| Narrative | An enbridge employee notified enterprise of a leak on the 8-inch crude line located on enbridge property. The line was immediately shutdown and cleanup actions implemented. Sunoco was in the process of delivering 43,700 barrels of crude oil to the cushing east facility when the release was discovered. A hydroexcavator was used to expose the pipeline and locate the source of the leak. A temporary clamp was installed to ensure no additional product was leaked and until a plidco clamp could be located and installed. The delivery resumed after the plidco clamp was installed with pumping restricted to daylight operations only. The recommendation is that the existing delivery line from the sunoco meter bank to the leak site be pigged, purged, filled with nitrogen and abandoned in place; isolating the line to the west facility fabricate and install a new, above ground 8-inch line from the sunoco meter bank to the sunoco delivery manifold that supplies the enterprise east facility. All future sunoco deliveries will be received into the cushing east facility. |