Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2011-11-07 — TX
Operator
Conocophillips
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$85,000
Incident datetime
2011-11-07 18:30
Report number
Location
TX
Narrative
On monday, 11/8, cppl personnel were notified of a crude oil leak on line 200 in concord, ca. Personnel were dispatched and the line was immediately shut down. There are 2 other 3rd party lines in the same row. Following excavation of the area, it was determined line 200 had a small external corrosion hole. Required notifications were made and the line was repaired and returned to service. External corrosion was the cause of this release.
Detailed record list
Report Received Date
2011-12-06 00:00:00
Iyear
2011
Report Number
20110436
Supplemental Number
16353
Report Type
Supplemental Final
Operator Id
31684
Name
Conocophillips
Operator Street Address
2331 Citywest Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Local Datetime
2011-11-07 18:30:00
Location Latitude
37.963297
Location Longitude
-121.948261
Commodity Released Type
Crude Oil
Unintentional Release Bbls
45
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2011-11-07 18:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-11-07 18:30:00
Restart Datetime
2011-11-10 17:00:00
On Site Datetime
2011-11-07 18:30:00
Nrc Rpt Datetime
2011-11-07 20:20:00
Nrc Rpt Num
994853
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Line 200
Segment Name
Nc-21
Onshore State Abbreviation
Ca
Onshore Postal Code
93455
Onshore City Name
Concord
Onshore County Name
Contra Costa
Designated Location
Survey Station No.
Designated Name
10993+00
Federal
Yes
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
42
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
16
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
X-52
Pipe Seam Type
Erw � Unknown Frequency
Pipe Coating Type
Coal Tar
Installation Year
1957
Manufactured Year
1957
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
4410
Est Cost Prop Damage
85000
Est Cost Emergency
1000000
Est Cost Environmental
750000
Est Cost Other
0
Prpty
1839410
Accident Psig
325
Mop Psig
990
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
Yes
Exceed Restriction Ind
No
Phmsa Restriction Ind
Not Mandated
Length Segment Isolated
36960
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Small external corrosion release found by third party.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Atmosphere Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1957
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2011
Prior Damage
No
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Ultrasonic Ind
Yes
Emat Ind
Yes
Axial Recent Year
2009
Geometry Recent Year
2009
Emat Recent Year
2009
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1991
Hydrtst Most Rcnt Pressure
1554
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
B**** G****
Preparer Title
Dot Coordinator
Preparer Email
B**********@c*************.com
Preparer Telephone
909-241-3358
Preparer Fax
562-290-1580
Prepared Date
2012-01-20 00:00:00
Authorizer Name
T*** T*****
Authorizer Telephone
832-379-6255
Authorizer Title
Manager Of Regulatory Compliance
Authorizer Email
T************@c*************.com
Narrative
On monday, 11/8, cppl personnel were notified of a crude oil leak on line 200 in concord, ca. Personnel were dispatched and the line was immediately shut down. There are 2 other 3rd party lines in the same row. Following excavation of the area, it was determined line 200 had a small external corrosion hole. Required notifications were made and the line was repaired and returned to service. External corrosion was the cause of this release.
| Report Received Date | 2011-12-06 00:00:00 |
|---|---|
| Iyear | 2011 |
| Report Number | 20110436 |
| Supplemental Number | 16353 |
| Report Type | Supplemental Final |
| Operator Id | 31684 PHMSA Enforcement |
| Name | Conocophillips |
| Operator Street Address | 2331 Citywest Blvd |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77042 |
| Local Datetime | 2011-11-07 18:30:00 |
| Location Latitude | 37.963297 Google Maps OpenStreetMap |
| Location Longitude | -121.948261 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 45 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Public |
| Incident Identified Datetime | 2011-11-07 18:30:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2011-11-07 18:30:00 |
| Restart Datetime | 2011-11-10 17:00:00 |
| On Site Datetime | 2011-11-07 18:30:00 |
| Nrc Rpt Datetime | 2011-11-07 20:20:00 |
| Nrc Rpt Num | 994853 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Valve Type Ind | Remotely Controlled |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Line 200 |
| Segment Name | Nc-21 |
| Onshore State Abbreviation | Ca |
| Onshore Postal Code | 93455 |
| Onshore City Name | Concord |
| Onshore County Name | Contra Costa |
| Designated Location | Survey Station No. |
| Designated Name | 10993+00 |
| Federal | Yes |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 42 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 16 |
| Pipe Wall Thickness | 0.25 |
| Pipe Smys | 52000 |
| Pipe Specification | X-52 |
| Pipe Seam Type | Erw � Unknown Frequency |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1957 |
| Manufactured Year | 1957 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Other Pop Ind | Yes |
| Other Pop Yes No | Yes |
| Usa Drinking Ind | Yes |
| Usa Drinking Yes No | Yes |
| Usa Ecological Ind | Yes |
| Usa Ecological Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 4410 |
| Est Cost Prop Damage | 85000 |
| Est Cost Emergency | 1000000 |
| Est Cost Environmental | 750000 |
| Est Cost Other | 0 |
| Prpty | 1839410 |
| Accident Psig | 325 |
| Mop Psig | 990 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | Yes |
| Exceed Restriction Ind | No |
| Phmsa Restriction Ind | Not Mandated |
| Length Segment Isolated | 36960 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Small external corrosion release found by third party. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Atmosphere Corrosion Ind | Yes |
| Field Exam Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | Yes |
| Cathodic Pro Start Year | 1957 |
| Shielding Evident | Yes |
| Cathodic Survey Type | Yes |
| Cp Annual Survey Ind | Yes |
| Cp Annual Survey Year | 2011 |
| Prior Damage | No |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Ultrasonic Ind | Yes |
| Emat Ind | Yes |
| Axial Recent Year | 2009 |
| Geometry Recent Year | 2009 |
| Emat Recent Year | 2009 |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 1991 |
| Hydrtst Most Rcnt Pressure | 1554 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | B**** G**** |
| Preparer Title | Dot Coordinator |
| Preparer Email | B**********@c*************.com |
| Preparer Telephone | 909-241-3358 |
| Preparer Fax | 562-290-1580 |
| Prepared Date | 2012-01-20 00:00:00 |
| Authorizer Name | T*** T***** |
| Authorizer Telephone | 832-379-6255 |
| Authorizer Title | Manager Of Regulatory Compliance |
| Authorizer Email | T************@c*************.com |
| Narrative | On monday, 11/8, cppl personnel were notified of a crude oil leak on line 200 in concord, ca. Personnel were dispatched and the line was immediately shut down. There are 2 other 3rd party lines in the same row. Following excavation of the area, it was determined line 200 had a small external corrosion hole. Required notifications were made and the line was repaired and returned to service. External corrosion was the cause of this release. |