HL incident on 2011-11-07 — TX

Operator
Conocophillips
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$85,000
Incident datetime
2011-11-07 18:30
Report number
Location
TX
Narrative
On monday, 11/8, cppl personnel were notified of a crude oil leak on line 200 in concord, ca. Personnel were dispatched and the line was immediately shut down. There are 2 other 3rd party lines in the same row. Following excavation of the area, it was determined line 200 had a small external corrosion hole. Required notifications were made and the line was repaired and returned to service. External corrosion was the cause of this release.
Detailed record list
Report Received Date
2011-12-06 00:00:00
Iyear
2011
Report Number
20110436
Supplemental Number
16353
Report Type
Supplemental Final
Operator Id
Name
Conocophillips
Operator Street Address
2331 Citywest Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Local Datetime
2011-11-07 18:30:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
45
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2011-11-07 18:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-11-07 18:30:00
Restart Datetime
2011-11-10 17:00:00
On Site Datetime
2011-11-07 18:30:00
Nrc Rpt Datetime
2011-11-07 20:20:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Line 200
Segment Name
Nc-21
Onshore State Abbreviation
Ca
Onshore Postal Code
93455
Onshore City Name
Concord
Onshore County Name
Contra Costa
Designated Location
Survey Station No.
Designated Name
10993+00
Federal
Yes
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
42
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
16
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
X-52
Pipe Seam Type
Erw � Unknown Frequency
Pipe Coating Type
Coal Tar
Installation Year
1957
Manufactured Year
1957
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
4410
Est Cost Prop Damage
85000
Est Cost Emergency
1000000
Est Cost Environmental
750000
Est Cost Other
0
Prpty
1839410
Accident Psig
325
Mop Psig
990
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
Yes
Exceed Restriction Ind
No
Phmsa Restriction Ind
Not Mandated
Length Segment Isolated
36960
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Small external corrosion release found by third party.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Atmosphere Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1957
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2011
Prior Damage
No
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Ultrasonic Ind
Yes
Emat Ind
Yes
Axial Recent Year
2009
Geometry Recent Year
2009
Emat Recent Year
2009
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1991
Hydrtst Most Rcnt Pressure
1554
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
B**** G****
Preparer Title
Dot Coordinator
Preparer Email
B**********@c*************.com
Preparer Telephone
909-241-3358
Preparer Fax
562-290-1580
Prepared Date
2012-01-20 00:00:00
Authorizer Name
T*** T*****
Authorizer Telephone
832-379-6255
Authorizer Title
Manager Of Regulatory Compliance
Authorizer Email
T************@c*************.com
Narrative
On monday, 11/8, cppl personnel were notified of a crude oil leak on line 200 in concord, ca. Personnel were dispatched and the line was immediately shut down. There are 2 other 3rd party lines in the same row. Following excavation of the area, it was determined line 200 had a small external corrosion hole. Required notifications were made and the line was repaired and returned to service. External corrosion was the cause of this release.
Report Received Date 2011-12-06 00:00:00
Iyear 2011
Report Number 20110436
Supplemental Number 16353
Report Type Supplemental Final
Operator Id 31684 PHMSA Enforcement
Name Conocophillips
Operator Street Address 2331 Citywest Blvd
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77042
Local Datetime 2011-11-07 18:30:00
Location Latitude 37.963297 Google Maps OpenStreetMap
Location Longitude -121.948261 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 45
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2011-11-07 18:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2011-11-07 18:30:00
Restart Datetime 2011-11-10 17:00:00
On Site Datetime 2011-11-07 18:30:00
Nrc Rpt Datetime 2011-11-07 20:20:00
Nrc Rpt Num 994853 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Remotely Controlled
Downstream Valve Type Ind Remotely Controlled
Num Pub Evacuated 0
Pipe Fac Name Line 200
Segment Name Nc-21
Onshore State Abbreviation Ca
Onshore Postal Code 93455
Onshore City Name Concord
Onshore County Name Contra Costa
Designated Location Survey Station No.
Designated Name 10993+00
Federal Yes
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 42
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 16
Pipe Wall Thickness 0.25
Pipe Smys 52000
Pipe Specification X-52
Pipe Seam Type Erw � Unknown Frequency
Pipe Coating Type Coal Tar
Installation Year 1957
Manufactured Year 1957
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Other Pop Ind Yes
Other Pop Yes No Yes
Usa Drinking Ind Yes
Usa Drinking Yes No Yes
Usa Ecological Ind Yes
Usa Ecological Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 4410
Est Cost Prop Damage 85000
Est Cost Emergency 1000000
Est Cost Environmental 750000
Est Cost Other 0
Prpty 1839410
Accident Psig 325
Mop Psig 990
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind Yes
Exceed Restriction Ind No
Phmsa Restriction Ind Not Mandated
Length Segment Isolated 36960
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Small external corrosion release found by third party.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Atmosphere Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1957
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Cp Annual Survey Year 2011
Prior Damage No
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Ultrasonic Ind Yes
Emat Ind Yes
Axial Recent Year 2009
Geometry Recent Year 2009
Emat Recent Year 2009
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1991
Hydrtst Most Rcnt Pressure 1554
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name B**** G****
Preparer Title Dot Coordinator
Preparer Email B**********@c*************.com
Preparer Telephone 909-241-3358
Preparer Fax 562-290-1580
Prepared Date 2012-01-20 00:00:00
Authorizer Name T*** T*****
Authorizer Telephone 832-379-6255
Authorizer Title Manager Of Regulatory Compliance
Authorizer Email T************@c*************.com
Narrative On monday, 11/8, cppl personnel were notified of a crude oil leak on line 200 in concord, ca. Personnel were dispatched and the line was immediately shut down. There are 2 other 3rd party lines in the same row. Following excavation of the area, it was determined line 200 had a small external corrosion hole. Required notifications were made and the line was repaired and returned to service. External corrosion was the cause of this release.

All rights reserved. Copyright © by ClearPHMSA