HL incident on 2011-11-02 — TX

Operator
Sunoco Pipeline L.p.
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2011-11-02 19:00
Report number
Location
TX
Narrative
A 3/8" stainless steel thermal relief fitting was improperly torqued resulting in the tubing not being properly locked into the compression fitting. The tubing slid out of the fitting and sprayed crude oil on the meter skid containment area. Re-submitted on 3/26/2013 to include part e5f per PHMSA request.
Detailed record list
Report Received Date
2011-11-17 00:00:00
Iyear
2011
Report Number
20110429
Supplemental Number
17685
Report Type
Supplemental Final
Operator Id
Name
Sunoco Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2011-11-02 19:00:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.48
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Incident Identified Datetime
2011-11-02 19:00:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
On Site Datetime
2011-11-02 19:00:00
Ignite Ind
No
Explode Ind
No
Pipe Fac Name
Big Spring Station
Segment Name
Amdel 10"
Onshore State Abbreviation
Tx
Onshore Postal Code
79720
Onshore City Name
Big Spring
Onshore County Name
Howard
Designated Location
Milepost/valve Station
Designated Name
Big Spring
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Pipe Facility Type
Intrastate
Item Involved
Tubing
Release Type
Leak
Leak Type
Connection Failure
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
45
Est Cost Prop Damage
0
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
45
Pipeline Function
> 20% Smys Regulated Transmission
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Defective Or Loose Tubing Or Fitting
Eq Failure Type
Defective Or Loose Tubing Or Fitting
Preparer Name
K****** D**** B***
Preparer Title
Area Dot Compliance Supervisor
Preparer Email
K*****@s**************.com
Preparer Telephone
281-637-6497
Preparer Fax
281-637-6425
Prepared Date
2013-03-26 00:00:00
Authorizer Name
K****** D**** B***
Authorizer Telephone
281-637-6497
Authorizer Title
Area Dot Compliance Supervisor
Authorizer Email
K*****@s**************.com
Narrative
A 3/8" stainless steel thermal relief fitting was improperly torqued resulting in the tubing not being properly locked into the compression fitting. The tubing slid out of the fitting and sprayed crude oil on the meter skid containment area. Re-submitted on 3/26/2013 to include part e5f per PHMSA request.
Report Received Date 2011-11-17 00:00:00
Iyear 2011
Report Number 20110429
Supplemental Number 17685
Report Type Supplemental Final
Operator Id 18718 PHMSA Enforcement
Name Sunoco Pipeline L.p.
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2011-11-02 19:00:00
Location Latitude 32.26812 Google Maps OpenStreetMap
Location Longitude -101.40486 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.48
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Incident Identified Datetime 2011-11-02 19:00:00
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
On Site Datetime 2011-11-02 19:00:00
Ignite Ind No
Explode Ind No
Pipe Fac Name Big Spring Station
Segment Name Amdel 10"
Onshore State Abbreviation Tx
Onshore Postal Code 79720
Onshore City Name Big Spring
Onshore County Name Howard
Designated Location Milepost/valve Station
Designated Name Big Spring
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Pipe Facility Type Intrastate
Item Involved Tubing
Release Type Leak
Leak Type Connection Failure
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 45
Est Cost Prop Damage 0
Est Cost Emergency 0
Est Cost Environmental 0
Est Cost Other 0
Prpty 45
Pipeline Function > 20% Smys Regulated Transmission
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Defective Or Loose Tubing Or Fitting
Eq Failure Type Defective Or Loose Tubing Or Fitting
Preparer Name K****** D**** B***
Preparer Title Area Dot Compliance Supervisor
Preparer Email K*****@s**************.com
Preparer Telephone 281-637-6497
Preparer Fax 281-637-6425
Prepared Date 2013-03-26 00:00:00
Authorizer Name K****** D**** B***
Authorizer Telephone 281-637-6497
Authorizer Title Area Dot Compliance Supervisor
Authorizer Email K*****@s**************.com
Narrative A 3/8" stainless steel thermal relief fitting was improperly torqued resulting in the tubing not being properly locked into the compression fitting. The tubing slid out of the fitting and sprayed crude oil on the meter skid containment area. Re-submitted on 3/26/2013 to include part e5f per PHMSA request.

All rights reserved. Copyright © by ClearPHMSA