HL incident on 2011-10-03 — TX
Operator
Mobil Corp
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$10,000
Incident datetime
2011-10-03 15:30
Report number
Location
TX
Narrative
On 10/3/11, the torrance refinery experienced a pinhole leak near the torrance meter station for the 8" truck unload relief pipeline. The leak resulted in a 41 bbl loss of primary containment of which all was contained within the confines and property of the exxonmobil refinery. This is a relief pipeline that protects exxonmobil pipeline company commodity pipelines which are upstream from the torrance meter station. This section of relief piping runs from the meter station to the 2 designated breakout tanks inside the refinery. As a result of the leak, the relief piping and exxonmobil pipeline commodity pipelines were immediately taken out of service. There was not a pressure surge incident, but rather, a pinhole leak had developed on the external relief piping that resulted in a loss of containment. Note: the ca state fire marshal's office of pipeline safety is aware of this incident and a csfm representative visited the site to review post incident, and reviewed the required hydrotesting that was conducted as part of recommissioning of the relief pipeline. Part e5f update was made 1/21/14 by thad massengale, exxonmobil pipeline co.
Detailed record list
Report Received Date
2011-11-02 00:00:00
Iyear
2011
Report Number
20110409
Supplemental Number
18946
Report Type
Supplemental Final
Operator Id
12624
Name
Mobil Corp
Operator Street Address
1795 Burt Street
Operator City Name
Beaumont
Operator State Abbreviation
TX
Operator Postal Code
77701
Local Datetime
2011-10-03 15:30:00
Location Latitude
33.84735
Location Longitude
-118.31848
Commodity Released Type
Crude Oil
Unintentional Release Bbls
41
Recovered Bbls
41
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2011-10-03 15:30:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
On Site Datetime
2011-10-03 15:35:00
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Onshore State Abbreviation
Ca
Onshore Postal Code
90504-2929
Onshore City Name
Torrance
Onshore County Name
Los Angeles
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
24
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8
Pipe Wall Thickness
0.322
Pipe Smys
35000
Pipe Specification
Grade B
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown, Year Of Manufacture Is Estimate
Pipe Coating Type
Cold Applied Tape
Manufactured Year
1960
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
4100
Est Cost Prop Damage
10000
Est Cost Emergency
5000
Est Cost Environmental
0
Est Cost Other
10000
Est Cost Other Details
Vacuum Truck Use To Clean Up Crude Leak From Ground
Prpty
29100
Accident Psig
10
Mop Psig
10
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Other Corrosion Ind
Yes
Corrosion Type Details
Differential Aeration Cells (Local Differences In Soil Packing And Moisture Content).
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
No
Shielding Evident
Yes
Cathodic Survey Type
No
Prior Damage
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
M*** D* J******
Preparer Title
Safety Advisor
Preparer Email
M****************@e*********.com
Preparer Telephone
310-212-4879
Preparer Fax
310-212-2937
Prepared Date
2014-01-21 00:00:00
Authorizer Name
M**** N*****
Authorizer Telephone
310-212-4673
Authorizer Title
Safety Group Leader
Authorizer Email
M*************@e*********.com
Narrative
On 10/3/11, the torrance refinery experienced a pinhole leak near the torrance meter station for the 8" truck unload relief pipeline. The leak resulted in a 41 bbl loss of primary containment of which all was contained within the confines and property of the exxonmobil refinery. This is a relief pipeline that protects exxonmobil pipeline company commodity pipelines which are upstream from the torrance meter station. This section of relief piping runs from the meter station to the 2 designated breakout tanks inside the refinery. As a result of the leak, the relief piping and exxonmobil pipeline commodity pipelines were immediately taken out of service. There was not a pressure surge incident, but rather, a pinhole leak had developed on the external relief piping that resulted in a loss of containment. Note: the ca state fire marshal's office of pipeline safety is aware of this incident and a csfm representative visited the site to review post incident, and reviewed the required hydrotesting that was conducted as part of recommissioning of the relief pipeline. Part e5f update was made 1/21/14 by thad massengale, exxonmobil pipeline co.
| Report Received Date | 2011-11-02 00:00:00 |
|---|---|
| Iyear | 2011 |
| Report Number | 20110409 |
| Supplemental Number | 18946 |
| Report Type | Supplemental Final |
| Operator Id | 12624 PHMSA Enforcement |
| Name | Mobil Corp |
| Operator Street Address | 1795 Burt Street |
| Operator City Name | Beaumont |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77701 |
| Local Datetime | 2011-10-03 15:30:00 |
| Location Latitude | 33.84735 Google Maps OpenStreetMap |
| Location Longitude | -118.31848 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 41 |
| Recovered Bbls | 41 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2011-10-03 15:30:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| On Site Datetime | 2011-10-03 15:35:00 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Onshore State Abbreviation | Ca |
| Onshore Postal Code | 90504-2929 |
| Onshore City Name | Torrance |
| Onshore County Name | Los Angeles |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 24 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 8 |
| Pipe Wall Thickness | 0.322 |
| Pipe Smys | 35000 |
| Pipe Specification | Grade B |
| Pipe Seam Type | Seamless |
| Pipe Manufacturer | Unknown, Year Of Manufacture Is Estimate |
| Pipe Coating Type | Cold Applied Tape |
| Manufactured Year | 1960 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 4100 |
| Est Cost Prop Damage | 10000 |
| Est Cost Emergency | 5000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 10000 |
| Est Cost Other Details | Vacuum Truck Use To Clean Up Crude Leak From Ground |
| Prpty | 29100 |
| Accident Psig | 10 |
| Mop Psig | 10 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the accident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Other Corrosion Ind | Yes |
| Corrosion Type Details | Differential Aeration Cells (Local Differences In Soil Packing And Moisture Content). |
| Field Exam Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | No |
| Shielding Evident | Yes |
| Cathodic Survey Type | No |
| Prior Damage | Yes |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | M*** D* J****** |
| Preparer Title | Safety Advisor |
| Preparer Email | M****************@e*********.com |
| Preparer Telephone | 310-212-4879 |
| Preparer Fax | 310-212-2937 |
| Prepared Date | 2014-01-21 00:00:00 |
| Authorizer Name | M**** N***** |
| Authorizer Telephone | 310-212-4673 |
| Authorizer Title | Safety Group Leader |
| Authorizer Email | M*************@e*********.com |
| Narrative | On 10/3/11, the torrance refinery experienced a pinhole leak near the torrance meter station for the 8" truck unload relief pipeline. The leak resulted in a 41 bbl loss of primary containment of which all was contained within the confines and property of the exxonmobil refinery. This is a relief pipeline that protects exxonmobil pipeline company commodity pipelines which are upstream from the torrance meter station. This section of relief piping runs from the meter station to the 2 designated breakout tanks inside the refinery. As a result of the leak, the relief piping and exxonmobil pipeline commodity pipelines were immediately taken out of service. There was not a pressure surge incident, but rather, a pinhole leak had developed on the external relief piping that resulted in a loss of containment. Note: the ca state fire marshal's office of pipeline safety is aware of this incident and a csfm representative visited the site to review post incident, and reviewed the required hydrotesting that was conducted as part of recommissioning of the relief pipeline. Part e5f update was made 1/21/14 by thad massengale, exxonmobil pipeline co. |