HL incident on 2011-08-11 — TX

Operator
Mustang Pipe Line Partners
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2011-08-11 15:18
Report number
Location
TX
Narrative
Outboard seal on the pump failed. The crude release from the seal was contained inside the pump room. All of the released crude was recovered using absorbent pads. Absorbent pads were placed into a 55 gallon drum for proper disposal at an exxonmobil approved facility. Supplemental report created on 8-22-12 to close open 7001 report as a final. 7-31-13 supplemental report PHMSA requested supplemental be created to added part e 5 f data ie, ( function of pipeline system) be added to form.
Detailed record list
Report Received Date
2011-09-08 00:00:00
Iyear
2011
Report Number
20110328
Supplemental Number
18373
Report Type
Supplemental Final
Operator Id
Name
Mustang Pipe Line Partners
Operator Street Address
22777 Springwoods Village Parkway E2.2b-Emp
Operator City Name
Spring
Operator State Abbreviation
TX
Operator Postal Code
77389
Local Datetime
2011-08-11 15:18:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.14
Intentional Release Bbls
0
Recovered Bbls
0.14
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Incident Identified Datetime
2011-08-11 15:18:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-08-11 15:22:00
Restart Datetime
2011-08-11 22:50:00
On Site Datetime
2011-08-11 15:29:00
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Wilmington Pump Station, Wilmington, Ill
Segment Name
18" Lockport To North Patoka
Onshore State Abbreviation
Il
Onshore Postal Code
60481
Onshore City Name
Wilmington
Onshore County Name
Will
Designated Location
Milepost/valve Station
Designated Name
118
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Pipe Facility Type
Interstate
Item Involved
Pump
Release Type
Leak
Leak Type
Seal Or Packing
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
12
Est Cost Prop Damage
0
Est Cost Emergency
0
Est Cost Environmental
185
Est Cost Other
0
Est Cost Other Details
Release Was Contained On The Pump Floor And Immediately Cleaned Up.
Prpty
197
Pipeline Function
> 20% Smys Regulated Transmission
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Preparer Name
L**** H********
Preparer Title
Pipeline Safety Advisor
Preparer Email
L****************@e*********.com
Preparer Telephone
903-654-5345
Preparer Fax
903-654-5374
Prepared Date
2013-07-31 00:00:00
Authorizer Name
M*** D W******
Authorizer Telephone
713-656-0227
Authorizer Title
Manager-Safety Health And Environmental Dept.
Authorizer Email
M*************@e*********.com
Narrative
Outboard seal on the pump failed. The crude release from the seal was contained inside the pump room. All of the released crude was recovered using absorbent pads. Absorbent pads were placed into a 55 gallon drum for proper disposal at an exxonmobil approved facility. Supplemental report created on 8-22-12 to close open 7001 report as a final. 7-31-13 supplemental report PHMSA requested supplemental be created to added part e 5 f data ie, ( function of pipeline system) be added to form.
Report Received Date 2011-09-08 00:00:00
Iyear 2011
Report Number 20110328
Supplemental Number 18373
Report Type Supplemental Final
Operator Id 31166 PHMSA Enforcement
Name Mustang Pipe Line Partners
Operator Street Address 22777 Springwoods Village Parkway E2.2b-Emp
Operator City Name Spring
Operator State Abbreviation TX
Operator Postal Code 77389
Local Datetime 2011-08-11 15:18:00
Location Latitude 41.27461 Google Maps OpenStreetMap
Location Longitude -88.12713 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.14
Intentional Release Bbls 0
Recovered Bbls 0.14
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Incident Identified Datetime 2011-08-11 15:18:00
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2011-08-11 15:22:00
Restart Datetime 2011-08-11 22:50:00
On Site Datetime 2011-08-11 15:29:00
Ignite Ind No
Explode Ind No
Num Pub Evacuated 0
Pipe Fac Name Wilmington Pump Station, Wilmington, Ill
Segment Name 18" Lockport To North Patoka
Onshore State Abbreviation Il
Onshore Postal Code 60481
Onshore City Name Wilmington
Onshore County Name Will
Designated Location Milepost/valve Station
Designated Name 118
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Pipe Facility Type Interstate
Item Involved Pump
Release Type Leak
Leak Type Seal Or Packing
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 12
Est Cost Prop Damage 0
Est Cost Emergency 0
Est Cost Environmental 185
Est Cost Other 0
Est Cost Other Details Release Was Contained On The Pump Floor And Immediately Cleaned Up.
Prpty 197
Pipeline Function > 20% Smys Regulated Transmission
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Pump Or Pump-Related Equipment
Eq Failure Type Pump Or Pump-Related Equipment
Preparer Name L**** H********
Preparer Title Pipeline Safety Advisor
Preparer Email L****************@e*********.com
Preparer Telephone 903-654-5345
Preparer Fax 903-654-5374
Prepared Date 2013-07-31 00:00:00
Authorizer Name M*** D W******
Authorizer Telephone 713-656-0227
Authorizer Title Manager-Safety Health And Environmental Dept.
Authorizer Email M*************@e*********.com
Narrative Outboard seal on the pump failed. The crude release from the seal was contained inside the pump room. All of the released crude was recovered using absorbent pads. Absorbent pads were placed into a 55 gallon drum for proper disposal at an exxonmobil approved facility. Supplemental report created on 8-22-12 to close open 7001 report as a final. 7-31-13 supplemental report PHMSA requested supplemental be created to added part e 5 f data ie, ( function of pipeline system) be added to form.

All rights reserved. Copyright © by ClearPHMSA