Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2011-06-29 — OK
Operator
Magellan Pipeline Company, Lp
Cause
Material Failure Of Pipe Or Weld
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$10,000
Incident datetime
2011-06-29 08:41
Report number
Location
OK
Narrative
A magellan crew was in the process of conducting rehabilitation digs from a previous in-line-inspection when wet, petroleum-impacted soil was identified next to the line where coating was coming off. The line was shut down and repair made consisting of removing the leaking specimen and replacing it with new, pre-tested pipe in accordance with company procedures. Impacted soil was tested and disposed of in accordance with acceptable company and state guidelines. A metallurgical analysis determined the release was a result of of an internal defect formed during casting prior to being made into a pipe. From this defect a crack grew by fatigue through the pipe wall.
Detailed record list
Report Received Date
2011-07-21 00:00:00
Iyear
2011
Report Number
20110251
Supplemental Number
20360
Report Type
Supplemental Final
Operator Id
22610
Name
Magellan Pipeline Company, Lp
Operator Street Address
100 West 5th Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2011-06-29 08:41:00
Location Latitude
40.74573
Location Longitude
-95.91459
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Other
Commodity Details
Gasoline-Diesel Mix
Unintentional Release Bbls
3
Intentional Release Bbls
0
Recovered Bbls
3
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2011-06-29 08:41:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-06-29 08:51:00
Restart Datetime
2011-06-30 14:14:00
On Site Datetime
2011-06-29 08:41:00
Nrc Rpt Datetime
2011-06-29 15:51:00
Nrc Rpt Num
985074
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
#5-12" Kansas City To Irvington Pipeline
Segment Name
#5-12'" Kansas City To Irvington Line
Onshore State Abbreviation
Ne
Onshore Postal Code
68410
Onshore City Name
Nebraska City
Onshore County Name
Otoe
Designated Location
Milepost/valve Station
Designated Name
144.64
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
24
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
12
Pipe Wall Thickness
0.312
Pipe Smys
42000
Pipe Specification
Api 5lx-42
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Installation Year
1972
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
3000
Est Cost Gas Released
325
Est Cost Prop Damage
10000
Est Cost Emergency
8000
Est Cost Environmental
130680
Est Cost Other
0
Prpty
152005
Accident Psig
821
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
253670
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The release was a slow seeper in nature, with the amount of product released below the alarm threshholds of scada and the leak warning tools. Therefore, it was concluded that operations control neither caused nor contributed to the release.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind
Yes
Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor
Yes
Other Factor Details
Root Cause Was An Internal Manufacturing Defect When The Steel Was Cast
Pwf Additional Other Ind
Yes
Collected Data Ind
Yes
Cir Trn Wave Mgn Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Circ Wave Recent Year
2001
Geometry Recent Year
2001
Other Recent Year
2011
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1990
Hydrtst Most Rcnt Pressure
1860
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
K****** L* L*******
Preparer Title
Sr. Compliance Coordinator
Preparer Email
K***********@m*********.com
Preparer Telephone
918-574-7315
Preparer Fax
918-574-7246
Prepared Date
2015-04-21 00:00:00
Authorizer Name
K****** L* L*******
Authorizer Telephone
918-574-7315
Authorizer Title
Sr. Compliance Coordinator
Authorizer Email
K***********@m*********.com
Narrative
A magellan crew was in the process of conducting rehabilitation digs from a previous in-line-inspection when wet, petroleum-impacted soil was identified next to the line where coating was coming off. The line was shut down and repair made consisting of removing the leaking specimen and replacing it with new, pre-tested pipe in accordance with company procedures. Impacted soil was tested and disposed of in accordance with acceptable company and state guidelines. A metallurgical analysis determined the release was a result of of an internal defect formed during casting prior to being made into a pipe. From this defect a crack grew by fatigue through the pipe wall.
| Report Received Date | 2011-07-21 00:00:00 |
|---|---|
| Iyear | 2011 |
| Report Number | 20110251 |
| Supplemental Number | 20360 |
| Report Type | Supplemental Final |
| Operator Id | 22610 PHMSA Enforcement |
| Name | Magellan Pipeline Company, Lp |
| Operator Street Address | 100 West 5th Street |
| Operator City Name | Tulsa |
| Operator State Abbreviation | OK |
| Operator Postal Code | 74103 |
| Local Datetime | 2011-06-29 08:41:00 |
| Location Latitude | 40.74573 Google Maps OpenStreetMap |
| Location Longitude | -95.91459 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Other |
| Commodity Details | Gasoline-Diesel Mix |
| Unintentional Release Bbls | 3 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 3 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2011-06-29 08:41:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2011-06-29 08:51:00 |
| Restart Datetime | 2011-06-30 14:14:00 |
| On Site Datetime | 2011-06-29 08:41:00 |
| Nrc Rpt Datetime | 2011-06-29 15:51:00 |
| Nrc Rpt Num | 985074 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Valve Type Ind | Remotely Controlled |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | #5-12" Kansas City To Irvington Pipeline |
| Segment Name | #5-12'" Kansas City To Irvington Line |
| Onshore State Abbreviation | Ne |
| Onshore Postal Code | 68410 |
| Onshore City Name | Nebraska City |
| Onshore County Name | Otoe |
| Designated Location | Milepost/valve Station |
| Designated Name | 144.64 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 24 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 12 |
| Pipe Wall Thickness | 0.312 |
| Pipe Smys | 42000 |
| Pipe Specification | Api 5lx-42 |
| Pipe Seam Type | Seamless |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1972 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | Yes |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 3000 |
| Est Cost Gas Released | 325 |
| Est Cost Prop Damage | 10000 |
| Est Cost Emergency | 8000 |
| Est Cost Environmental | 130680 |
| Est Cost Other | 0 |
| Prpty | 152005 |
| Accident Psig | 821 |
| Mop Psig | 1440 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 253670 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The release was a slow seeper in nature, with the amount of product released below the alarm threshholds of scada and the leak warning tools. Therefore, it was concluded that operations control neither caused nor contributed to the release. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Material Failure Of Pipe Or Weld |
| Cause Details | Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field) |
| Metallurgical Ind | Yes |
| Failure Type | Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field) |
| Other Factor | Yes |
| Other Factor Details | Root Cause Was An Internal Manufacturing Defect When The Steel Was Cast |
| Pwf Additional Other Ind | Yes |
| Collected Data Ind | Yes |
| Cir Trn Wave Mgn Flx Lkg Ind | Yes |
| Geometry Deformation Ind | Yes |
| Circ Wave Recent Year | 2001 |
| Geometry Recent Year | 2001 |
| Other Recent Year | 2011 |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 1990 |
| Hydrtst Most Rcnt Pressure | 1860 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | K****** L* L******* |
| Preparer Title | Sr. Compliance Coordinator |
| Preparer Email | K***********@m*********.com |
| Preparer Telephone | 918-574-7315 |
| Preparer Fax | 918-574-7246 |
| Prepared Date | 2015-04-21 00:00:00 |
| Authorizer Name | K****** L* L******* |
| Authorizer Telephone | 918-574-7315 |
| Authorizer Title | Sr. Compliance Coordinator |
| Authorizer Email | K***********@m*********.com |
| Narrative | A magellan crew was in the process of conducting rehabilitation digs from a previous in-line-inspection when wet, petroleum-impacted soil was identified next to the line where coating was coming off. The line was shut down and repair made consisting of removing the leaking specimen and replacing it with new, pre-tested pipe in accordance with company procedures. Impacted soil was tested and disposed of in accordance with acceptable company and state guidelines. A metallurgical analysis determined the release was a result of of an internal defect formed during casting prior to being made into a pipe. From this defect a crack grew by fatigue through the pipe wall. |