HL incident on 2011-05-14 — OK

Operator
Oneok Ngl Pipeline Lp
Cause
Corrosion Failure
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$549,459
Incident datetime
2011-05-14 15:40
Report number
Location
OK
Narrative
Third party reported product running out of pipeline vent pipes on oneok 106w pipeline at 135th st crossing in romeoville, ill. Pipeline control center shut down pipeline and dispatched oneok personnel. Pipeline was isolated by blockvalves and product was flared at oneok lemont station. Carrier pipe at road crossing was removed and replaced with new pipe. Replacement pipe was hydrostatically tested before line was returned to operation. Failed pipe was sent out for metallurgical analysis (kiefner & assoc.) to determine cause of failure. Leak was caused by external corrosion of the pipe body within a cased road crossing. An isolated corrosion pit was found underneasth a casing spacer. The metal loss had reached a depth of 93% wall thickness, at which point the remaining ligament failed due to internal pressure and a quarter-inch tear formed. The casing spacers used for this particular crossing were comprised of bolt-on steel sleeves that were insulated and cushioned from the coated pipe surface with a rubber pad. The rubber pad was out of position on the casing spacer that was over the leak such that part of the steel spacer was in contact with the pipe surface.
Detailed record list
Report Received Date
2011-05-15 00:00:00
Iyear
2011
Report Number
20110141
Supplemental Number
16340
Report Type
Supplemental Final
Operator Id
Name
Oneok Ngl Pipeline Lp
Operator Street Address
100 West Fifth Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2011-05-14 15:40:00
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Refinery Grade Butane
Unintentional Release Bbls
100
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Emergency Responder
Incident Identified Datetime
2011-05-14 15:40:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-05-14 15:40:00
Restart Datetime
2011-05-27 18:30:00
On Site Datetime
2011-05-14 16:30:00
Nrc Rpt Datetime
2011-05-14 19:55:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
25
Pipe Fac Name
Oneok North System 106w Pipeline
Segment Name
106w Pipeline Index 11106
Onshore State Abbreviation
Il
Onshore Postal Code
60446
Onshore City Name
Romeoville
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
100
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Cased
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8.625
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
Smaw
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Cold Applied Tape
Installation Year
1967
Manufactured Year
1967
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Leak Type Other
Unknown At This Time
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
100
Rel Water Name
Unnamed Wetlands
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
20000
Est Cost Gas Released
7140
Est Cost Prop Damage
549459
Est Cost Emergency
15000
Est Cost Environmental
129589
Est Cost Other
0
Prpty
721188
Accident Psig
1141
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
77774
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Operator determined controllers actions did not contribute to the release
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Metallurgical Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1968
Shielding Evident
No
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2011
Prior Damage
No
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Axial Recent Year
2007
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
N*** J****
Preparer Title
Dot Compliance Coordinator
Preparer Email
N*********@o****.com
Preparer Telephone
580-395-6304
Preparer Fax
580-395-2933
Prepared Date
2012-01-17 00:00:00
Authorizer Name
N*** J****
Authorizer Telephone
580-395-6304
Authorizer Title
Dot Compliance Coordinator
Authorizer Email
N*********@o****.com
Narrative
Third party reported product running out of pipeline vent pipes on oneok 106w pipeline at 135th st crossing in romeoville, ill. Pipeline control center shut down pipeline and dispatched oneok personnel. Pipeline was isolated by blockvalves and product was flared at oneok lemont station. Carrier pipe at road crossing was removed and replaced with new pipe. Replacement pipe was hydrostatically tested before line was returned to operation. Failed pipe was sent out for metallurgical analysis (kiefner & assoc.) to determine cause of failure. Leak was caused by external corrosion of the pipe body within a cased road crossing. An isolated corrosion pit was found underneasth a casing spacer. The metal loss had reached a depth of 93% wall thickness, at which point the remaining ligament failed due to internal pressure and a quarter-inch tear formed. The casing spacers used for this particular crossing were comprised of bolt-on steel sleeves that were insulated and cushioned from the coated pipe surface with a rubber pad. The rubber pad was out of position on the casing spacer that was over the leak such that part of the steel spacer was in contact with the pipe surface.
Report Received Date 2011-05-15 00:00:00
Iyear 2011
Report Number 20110141
Supplemental Number 16340
Report Type Supplemental Final
Operator Id 32109 PHMSA Enforcement
Name Oneok Ngl Pipeline Lp
Operator Street Address 100 West Fifth Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Local Datetime 2011-05-14 15:40:00
Location Latitude 41.639016 Google Maps OpenStreetMap
Location Longitude -88.124155 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Other Hvl
Commodity Details Refinery Grade Butane
Unintentional Release Bbls 100
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Emergency Responder
Incident Identified Datetime 2011-05-14 15:40:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2011-05-14 15:40:00
Restart Datetime 2011-05-27 18:30:00
On Site Datetime 2011-05-14 16:30:00
Nrc Rpt Datetime 2011-05-14 19:55:00
Nrc Rpt Num 976327 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 25
Pipe Fac Name Oneok North System 106w Pipeline
Segment Name 106w Pipeline Index 11106
Onshore State Abbreviation Il
Onshore Postal Code 60446
Onshore City Name Romeoville
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Pavement
Depth Of Cover 100
Crossing Yes
Road Crossing Ind Yes
Road Type Cased
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 8.625
Pipe Wall Thickness 0.25
Pipe Smys 52000
Pipe Specification Smaw
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Cold Applied Tape
Installation Year 1967
Manufactured Year 1967
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Leak Type Other Unknown At This Time
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind Yes
Surface Contam Ind Yes
Amount Released 100
Rel Water Name Unnamed Wetlands
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 20000
Est Cost Gas Released 7140
Est Cost Prop Damage 549459
Est Cost Emergency 15000
Est Cost Environmental 129589
Est Cost Other 0
Prpty 721188
Accident Psig 1141
Mop Psig 1440
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 77774
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Operator determined controllers actions did not contribute to the release
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Metallurgical Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1968
Shielding Evident No
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Cp Annual Survey Year 2011
Prior Damage No
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Axial Recent Year 2007
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name N*** J****
Preparer Title Dot Compliance Coordinator
Preparer Email N*********@o****.com
Preparer Telephone 580-395-6304
Preparer Fax 580-395-2933
Prepared Date 2012-01-17 00:00:00
Authorizer Name N*** J****
Authorizer Telephone 580-395-6304
Authorizer Title Dot Compliance Coordinator
Authorizer Email N*********@o****.com
Narrative Third party reported product running out of pipeline vent pipes on oneok 106w pipeline at 135th st crossing in romeoville, ill. Pipeline control center shut down pipeline and dispatched oneok personnel. Pipeline was isolated by blockvalves and product was flared at oneok lemont station. Carrier pipe at road crossing was removed and replaced with new pipe. Replacement pipe was hydrostatically tested before line was returned to operation. Failed pipe was sent out for metallurgical analysis (kiefner & assoc.) to determine cause of failure. Leak was caused by external corrosion of the pipe body within a cased road crossing. An isolated corrosion pit was found underneasth a casing spacer. The metal loss had reached a depth of 93% wall thickness, at which point the remaining ligament failed due to internal pressure and a quarter-inch tear formed. The casing spacers used for this particular crossing were comprised of bolt-on steel sleeves that were insulated and cushioned from the coated pipe surface with a rubber pad. The rubber pad was out of position on the casing spacer that was over the leak such that part of the steel spacer was in contact with the pipe surface.

All rights reserved. Copyright © by ClearPHMSA