HL incident on 2011-03-14 — OK

Operator
Magellan Terminals Holdings, Lp
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$35,000
Incident datetime
2011-03-14 08:50
Report number
Location
OK
Narrative
A notification from the ct dep was received regarding a sheen on the water. Immediate response action was taken and an investigation started consisting of drilling potholes in the area. It was determined that a pinhole leak had caused the release.
Detailed record list
Report Received Date
2011-04-13 00:00:00
Iyear
2011
Report Number
20110118
Supplemental Number
16659
Report Type
Supplemental Final
Operator Id
Name
Magellan Terminals Holdings, Lp
Operator Street Address
100 West 5th Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2011-03-14 08:30:00
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
600
Intentional Release Bbls
0
Recovered Bbls
296
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Notified By The Ct Dep
Incident Identified Datetime
2011-03-14 08:50:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
On Site Datetime
2011-03-14 09:30:00
Nrc Rpt Datetime
2011-03-14 00:00:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Hamden New Haven 8"
Segment Name
Station 28+50
Onshore State Abbreviation
Ct
Onshore Postal Code
06514
Onshore City Name
Hamden
Onshore County Name
New Haven
Designated Location
Survey Station No.
Designated Name
28+50
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8.625
Pipe Wall Thickness
0.277
Pipe Smys
24000
Pipe Specification
5la-25
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Installation Year
1955
Manufactured Year
1955
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Groundwater Remed Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Ocean Seawater Ind
Yes
Surface Contam Ind
Yes
Groundwater Contam Ind
Yes
Amount Released
5.7
Rel Water Name
Millriver
Could Be Hca
Yes
Commodity Reached Hca
Yes
Commercially Nav Ind
Yes
Commercially Nav Yes No
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
100000
Est Cost Gas Released
80000
Est Cost Prop Damage
35000
Est Cost Emergency
200000
Est Cost Environmental
1817739
Est Cost Other
0
Prpty
2232739
Accident Psig
50
Mop Psig
188
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
4834
Internal Inspection Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Scada did show any indications of and aoc or leak condition. This was a pinhole leak.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1970
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2010
Close Interval Survey Year
2010
Prior Damage
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2006
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
D******* C*********
Prepared Date
2012-05-31 00:00:00
Authorizer Name
D******* C*********
Authorizer Telephone
9185747386
Authorizer Title
Sr. Compliance Coordinator
Authorizer Email
D******************@m*********.com
Narrative
A notification from the ct dep was received regarding a sheen on the water. Immediate response action was taken and an investigation started consisting of drilling potholes in the area. It was determined that a pinhole leak had caused the release.
Report Received Date 2011-04-13 00:00:00
Iyear 2011
Report Number 20110118
Supplemental Number 16659
Report Type Supplemental Final
Operator Id 31580 PHMSA Enforcement
Name Magellan Terminals Holdings, Lp
Operator Street Address 100 West 5th Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Local Datetime 2011-03-14 08:30:00
Location Latitude 41.307 Google Maps OpenStreetMap
Location Longitude -72.90925 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls 600
Intentional Release Bbls 0
Recovered Bbls 296
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Other
Accident Details Notified By The Ct Dep
Incident Identified Datetime 2011-03-14 08:50:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
On Site Datetime 2011-03-14 09:30:00
Nrc Rpt Datetime 2011-03-14 00:00:00
Nrc Rpt Num 970019 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Hamden New Haven 8"
Segment Name Station 28+50
Onshore State Abbreviation Ct
Onshore Postal Code 06514
Onshore City Name Hamden
Onshore County Name New Haven
Designated Location Survey Station No.
Designated Name 28+50
Federal No
Location Type Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 36
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 8.625
Pipe Wall Thickness 0.277
Pipe Smys 24000
Pipe Specification 5la-25
Pipe Seam Type Seamless
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Installation Year 1955
Manufactured Year 1955
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment Yes
Remediation Ind Yes
Groundwater Remed Ind Yes
Soil Remed Ind Yes
Water Contam Ind Yes
Ocean Seawater Ind Yes
Surface Contam Ind Yes
Groundwater Contam Ind Yes
Amount Released 5.7
Rel Water Name Millriver
Could Be Hca Yes
Commodity Reached Hca Yes
Commercially Nav Ind Yes
Commercially Nav Yes No Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 100000
Est Cost Gas Released 80000
Est Cost Prop Damage 35000
Est Cost Emergency 200000
Est Cost Environmental 1817739
Est Cost Other 0
Prpty 2232739
Accident Psig 50
Mop Psig 188
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 4834
Internal Inspection Ind No
Pipeline Function < 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Scada did show any indications of and aoc or leak condition. This was a pinhole leak.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1970
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2010
Close Interval Survey Year 2010
Prior Damage Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2006
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name D******* C*********
Prepared Date 2012-05-31 00:00:00
Authorizer Name D******* C*********
Authorizer Telephone 9185747386
Authorizer Title Sr. Compliance Coordinator
Authorizer Email D******************@m*********.com
Narrative A notification from the ct dep was received regarding a sheen on the water. Immediate response action was taken and an investigation started consisting of drilling potholes in the area. It was determined that a pinhole leak had caused the release.

All rights reserved. Copyright © by ClearPHMSA