Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2011-03-07 — OH
Operator
Marathon Pipe Line Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2011-03-07 07:50
Report number
Location
OH
Narrative
Catastrophic failure of unit 5 packing. Cause of packing failure was determined to be component fatigue.
Detailed record list
Report Received Date
2011-03-31 00:00:00
Iyear
2011
Report Number
20110110
Supplemental Number
17965
Report Type
Supplemental Final
Operator Id
32147
Name
Marathon Pipe Line Llc
Operator Street Address
539 South Main Street
Operator City Name
Findlay
Operator State Abbreviation
OH
Operator Postal Code
45840
Local Datetime
2011-03-07 07:50:00
Location Latitude
44.815639
Location Longitude
-108.498916
Commodity Released Type
Crude Oil
Unintentional Release Bbls
80
Intentional Release Bbls
0
Recovered Bbls
80
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Notification From A Production Company.
Incident Identified Datetime
2011-03-07 07:50:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2011-03-07 07:50:00
Restart Datetime
2011-03-07 17:45:00
On Site Datetime
2011-03-07 08:10:00
Nrc Rpt Datetime
2011-03-07 10:10:00
Nrc Rpt Num
969377
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Byron - Silvertip 12"-10" Crude
Segment Name
Byron - Silvertip 12"-10" Crude
Onshore State Abbreviation
Wy
Onshore Postal Code
82412
Onshore City Name
Byron
Onshore County Name
Big Horn
Designated Location
Milepost/valve Station
Designated Name
Byron Stn
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pump
Installation Year
1999
Material Involved
Material Other Than Carbon Steel
Material Details
Unit Packing
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
8000
Est Cost Prop Damage
0
Est Cost Emergency
22572
Est Cost Environmental
0
Est Cost Other
0
Prpty
30572
Accident Psig
860
Mop Psig
1000
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Seal/packing Failure
Eq Additional Other Ind
Yes
Eq Additional Other Details
Component Fatigue
Preparer Name
R**** S********
Preparer Title
Hes Professional
Preparer Email
R**********@m****************.com
Preparer Telephone
4194212121
Prepared Date
2013-04-29 00:00:00
Authorizer Name
R****** B*****
Authorizer Telephone
4194212121
Authorizer Title
Regulatory Compliance Supervisor
Authorizer Email
R*******@m****************.com
Narrative
Catastrophic failure of unit 5 packing. Cause of packing failure was determined to be component fatigue.
| Report Received Date | 2011-03-31 00:00:00 |
|---|---|
| Iyear | 2011 |
| Report Number | 20110110 |
| Supplemental Number | 17965 |
| Report Type | Supplemental Final |
| Operator Id | 32147 PHMSA Enforcement |
| Name | Marathon Pipe Line Llc |
| Operator Street Address | 539 South Main Street |
| Operator City Name | Findlay |
| Operator State Abbreviation | OH |
| Operator Postal Code | 45840 |
| Local Datetime | 2011-03-07 07:50:00 |
| Location Latitude | 44.815639 Google Maps OpenStreetMap |
| Location Longitude | -108.498916 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 80 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 80 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Other |
| Accident Details | Notification From A Production Company. |
| Incident Identified Datetime | 2011-03-07 07:50:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2011-03-07 07:50:00 |
| Restart Datetime | 2011-03-07 17:45:00 |
| On Site Datetime | 2011-03-07 08:10:00 |
| Nrc Rpt Datetime | 2011-03-07 10:10:00 |
| Nrc Rpt Num | 969377 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Byron - Silvertip 12"-10" Crude |
| Segment Name | Byron - Silvertip 12"-10" Crude |
| Onshore State Abbreviation | Wy |
| Onshore Postal Code | 82412 |
| Onshore City Name | Byron |
| Onshore County Name | Big Horn |
| Designated Location | Milepost/valve Station |
| Designated Name | Byron Stn |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pump |
| Installation Year | 1999 |
| Material Involved | Material Other Than Carbon Steel |
| Material Details | Unit Packing |
| Release Type | Leak |
| Leak Type | Seal Or Packing |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 8000 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 22572 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 30572 |
| Accident Psig | 860 |
| Mop Psig | 1000 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Pump Or Pump-Related Equipment |
| Eq Failure Type | Pump Or Pump-Related Equipment |
| Other Pump Ind | Seal/packing Failure |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | Component Fatigue |
| Preparer Name | R**** S******** |
| Preparer Title | Hes Professional |
| Preparer Email | R**********@m****************.com |
| Preparer Telephone | 4194212121 |
| Prepared Date | 2013-04-29 00:00:00 |
| Authorizer Name | R****** B***** |
| Authorizer Telephone | 4194212121 |
| Authorizer Title | Regulatory Compliance Supervisor |
| Authorizer Email | R*******@m****************.com |
| Narrative | Catastrophic failure of unit 5 packing. Cause of packing failure was determined to be component fatigue. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA