HL incident on 2010-08-17 — PA

Operator
Buckeye Partners, Lp
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2010-08-17 08:30
Report number
Location
PA
Narrative
At 8:30 am on august 17, 2010 buckeye was notified by a contractor working in the area of a gasoline odor and a sheen on newtown creek. Buckeye immediately instituted emergency response procedures and shut down and isolated the pipelines it operates in the area. Buckeye personnel determined that there was a release in the area of a valve vault next to newtown creek and all released product has been recovered. The pipeline has been excavated and a temporary repair has been made. A metallurgical analysis to determine the cause will be performed when the pipe is cut out and a permanent repair is made. Update 6/6/12 the damaged pipe was cut out and a permanent repair made. The metallurgical analysis determined that the cause of the release was external atmospheric corrosion.
Detailed record list
Report Received Date
2010-09-14 00:00:00
Iyear
2010
Report Number
20100199
Supplemental Number
16670
Report Type
Supplemental Final
Operator Id
Name
Buckeye Partners, Lp
Operator Street Address
The Buckeye Building 6161 Hamilton Boulevar
Operator City Name
Allentown
Operator State Abbreviation
PA
Operator Postal Code
18106
Local Datetime
2010-08-17 08:30:00
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
0.23
Recovered Bbls
0.23
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2010-08-17 08:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2010-08-17 08:30:00
Restart Datetime
2010-08-19 18:56:00
On Site Datetime
2010-08-17 09:15:00
Nrc Rpt Datetime
2010-08-17 11:20:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Automatic
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Long Island City To Motiva Gas
Segment Name
Ly999a1
Onshore State Abbreviation
Ny
Onshore Postal Code
11222
Onshore City Name
Brooklyn
Onshore County Name
Kings
Designated Location
Survey Station No.
Designated Name
523
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
In Underground Enclosed Space (E.g. Vault)
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
12.75
Pipe Wall Thickness
0.25
Pipe Smys
2353
Pipe Specification
X-60
Pipe Seam Type
Erw � Unknown Frequency
Pipe Coating Type
Asphalt
Installation Year
1965
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
0.02
Rel Water Name
Newtown Creek
Could Be Hca
Yes
Commodity Reached Hca
Yes
Commercially Nav Ind
Yes
Commercially Nav Yes No
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
0
Est Cost Emergency
135935
Est Cost Environmental
363400
Est Cost Other
0
Prpty
499335
Accident Psig
0
Mop Psig
275
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
554
Internal Inspection Ind
No
Tight Mitered Ind
Yes
Operation Complications Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Atmosphere Corrosion Ind
Yes
Metallurgical Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1965
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2010
Prior Damage
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2009
Hydrtst Most Rcnt Pressure
440
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
B*** Y**********
Preparer Title
Compliance Specialist
Preparer Email
B***********@b******.com
Preparer Telephone
610-904-4958
Preparer Fax
610-904-4545
Prepared Date
2012-06-06 00:00:00
Authorizer Name
J*** R*******
Authorizer Telephone
610-904-4185
Authorizer Title
Group Leader Regulatory Compliance
Authorizer Email
J********@b******.com
Narrative
At 8:30 am on august 17, 2010 buckeye was notified by a contractor working in the area of a gasoline odor and a sheen on newtown creek. Buckeye immediately instituted emergency response procedures and shut down and isolated the pipelines it operates in the area. Buckeye personnel determined that there was a release in the area of a valve vault next to newtown creek and all released product has been recovered. The pipeline has been excavated and a temporary repair has been made. A metallurgical analysis to determine the cause will be performed when the pipe is cut out and a permanent repair is made. Update 6/6/12 the damaged pipe was cut out and a permanent repair made. The metallurgical analysis determined that the cause of the release was external atmospheric corrosion.
Report Received Date 2010-09-14 00:00:00
Iyear 2010
Report Number 20100199
Supplemental Number 16670
Report Type Supplemental Final
Operator Id 1845 PHMSA Enforcement
Name Buckeye Partners, Lp
Operator Street Address The Buckeye Building 6161 Hamilton Boulevar
Operator City Name Allentown
Operator State Abbreviation PA
Operator Postal Code 18106
Local Datetime 2010-08-17 08:30:00
Location Latitude 40.73625 Google Maps OpenStreetMap
Location Longitude -73.94435 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Gasoline (Non-Ethanol)
Unintentional Release Bbls 0.23
Recovered Bbls 0.23
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2010-08-17 08:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2010-08-17 08:30:00
Restart Datetime 2010-08-19 18:56:00
On Site Datetime 2010-08-17 09:15:00
Nrc Rpt Datetime 2010-08-17 11:20:00
Nrc Rpt Num 951221 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Automatic
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Long Island City To Motiva Gas
Segment Name Ly999a1
Onshore State Abbreviation Ny
Onshore Postal Code 11222
Onshore City Name Brooklyn
Onshore County Name Kings
Designated Location Survey Station No.
Designated Name 523
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype In Underground Enclosed Space (E.g. Vault)
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 12.75
Pipe Wall Thickness 0.25
Pipe Smys 2353
Pipe Specification X-60
Pipe Seam Type Erw � Unknown Frequency
Pipe Coating Type Asphalt
Installation Year 1965
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind Yes
Surface Contam Ind Yes
Amount Released 0.02
Rel Water Name Newtown Creek
Could Be Hca Yes
Commodity Reached Hca Yes
Commercially Nav Ind Yes
Commercially Nav Yes No Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 0
Est Cost Emergency 135935
Est Cost Environmental 363400
Est Cost Other 0
Prpty 499335
Accident Psig 0
Mop Psig 275
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 554
Internal Inspection Ind No
Tight Mitered Ind Yes
Operation Complications Ind No
Pipeline Function < 20% Smys Regulated Transmission
Scada In Place Ind No
Cpm In Place Ind No
Investigation Status No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Atmosphere Corrosion Ind Yes
Metallurgical Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1965
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Cp Annual Survey Year 2010
Prior Damage Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2009
Hydrtst Most Rcnt Pressure 440
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name B*** Y**********
Preparer Title Compliance Specialist
Preparer Email B***********@b******.com
Preparer Telephone 610-904-4958
Preparer Fax 610-904-4545
Prepared Date 2012-06-06 00:00:00
Authorizer Name J*** R*******
Authorizer Telephone 610-904-4185
Authorizer Title Group Leader Regulatory Compliance
Authorizer Email J********@b******.com
Narrative At 8:30 am on august 17, 2010 buckeye was notified by a contractor working in the area of a gasoline odor and a sheen on newtown creek. Buckeye immediately instituted emergency response procedures and shut down and isolated the pipelines it operates in the area. Buckeye personnel determined that there was a release in the area of a valve vault next to newtown creek and all released product has been recovered. The pipeline has been excavated and a temporary repair has been made. A metallurgical analysis to determine the cause will be performed when the pipe is cut out and a permanent repair is made. Update 6/6/12 the damaged pipe was cut out and a permanent repair made. The metallurgical analysis determined that the cause of the release was external atmospheric corrosion.

All rights reserved. Copyright © by ClearPHMSA