GTG incident on 2010-09-25 — TX

Operator
East Tennessee Natural Gas Co
Cause
Material Failure Of Pipe Or Weld
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$50,000
Incident datetime
2010-09-25 20:00
Report number
Location
TX
Narrative
A small leak was detected on east tennessee natural gas line 3200-1 during a routine instrumented leak survey. The leak originated at the pipe weld seam. The leaking pipe was removed and a metallurgical analysis was performed. The metallurgical analysis determined the leak was the result of lack of fusion in the pipe weld seam.
Detailed record list
Report Received Date
2010-10-20 00:00:00
Iyear
2010
Report Number
20100078
Supplemental Number
15157
Report Type
Supplemental Final
Operator Id
Name
East Tennessee Natural Gas Co
Operator Street Address
915 North Eldridge Parkway
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Local Datetime
2010-09-25 20:00:00
Location Latitude
Location Longitude
Nrc Rpt Num
Nrc Rpt Datetime
2010-09-25 21:15:00
Commodity Released Type
Natural Gas
Unintentional Release
50
Intentional Release
1383
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2010-09-25 20:00:00
Restart Datetime
2010-09-26 19:58:00
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Incident Identified Datetime
2010-09-25 20:00:00
On Site Datetime
2010-09-25 20:00:00
On Off Shore
Onshore
Onshore State Abbreviation
Tn
Onshore Postal Code
37416
Onshore City Name
Chattanooga
Onshore County Name
Hamilton
Designated Location
Survey Station No.
Designated Name
304+27
Pipe Fac Name
3200-1
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
30
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
12.75
Pipe Wall Thickness
0.25
Pipe Smys
42000
Pipe Specification
Api-5l X-42
Pipe Seam Type
Longitudinal Erw - Low Frequency
Pipe Manufacturer
Republic
Pipe Coating Type
Composite
Installation Year
1950
Manufactured Year
1950
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Class Location Type
Class 3 Location
Could Be Hca
No
Pir Radius
253
Heat Damage Ind
No
Non Heat Damage Ind
No
Hca Fatalities Ind
No
Est Cost Oper Paid
2500
Est Cost Unintentional Release
200
Est Cost Intentional Release
5532
Est Cost Prop Damage
50000
Est Cost Emergency
0
Est Cost Other
0
Prpty
58232
Accident Psig
744
Mop Psig
823
Mop Cfr Section
Not On Omb-Approved Form When Submitted
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
28224
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Contractor Working For The Operator
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The gas loss was so insignificant that scada would not be able to detect it.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Pwjf Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Field Exam Ind
Yes
Metallurgical Ind
Yes
Other Factor
Yes
Other Factor Details
Undetermined
Additional Lack Fusion Ind
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Axial Recent Year
2004
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1994
Hydrtst Most Rcnt Pressure
1260
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
D***** T**********
Preparer Title
Principal Engineer
Preparer Email
D************@s************.com
Preparer Telephone
713-627-5573
Preparer Fax
713-386-4468
Authorizer Name
R*** K*****
Authorizer Title
Director Of Operational Compliance
Authorizer Telephone
713-627-6388
Authorizer Email
R*******@s************.com
Narrative
A small leak was detected on east tennessee natural gas line 3200-1 during a routine instrumented leak survey. The leak originated at the pipe weld seam. The leaking pipe was removed and a metallurgical analysis was performed. The metallurgical analysis determined the leak was the result of lack of fusion in the pipe weld seam.
Report Received Date 2010-10-20 00:00:00
Iyear 2010
Report Number 20100078
Supplemental Number 15157
Report Type Supplemental Final
Operator Id 4070 PHMSA Enforcement
Name East Tennessee Natural Gas Co
Operator Street Address 915 North Eldridge Parkway
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77079
Local Datetime 2010-09-25 20:00:00
Location Latitude 35.0882 Google Maps OpenStreetMap
Location Longitude -85.2114 Google Maps OpenStreetMap
Nrc Rpt Num 955164 NRC Report How to search
Nrc Rpt Datetime 2010-09-25 21:15:00
Commodity Released Type Natural Gas
Unintentional Release 50
Intentional Release 1383
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Shutdown Due Accident Ind Yes
Shutdown Datetime 2010-09-25 20:00:00
Restart Datetime 2010-09-26 19:58:00
Ignite Ind No
Explode Ind No
Num Pub Evacuated 0
Incident Identified Datetime 2010-09-25 20:00:00
On Site Datetime 2010-09-25 20:00:00
On Off Shore Onshore
Onshore State Abbreviation Tn
Onshore Postal Code 37416
Onshore City Name Chattanooga
Onshore County Name Hamilton
Designated Location Survey Station No.
Designated Name 304+27
Pipe Fac Name 3200-1
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 30
Crossing No
Pipe Facility Type Interstate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 12.75
Pipe Wall Thickness 0.25
Pipe Smys 42000
Pipe Specification Api-5l X-42
Pipe Seam Type Longitudinal Erw - Low Frequency
Pipe Manufacturer Republic
Pipe Coating Type Composite
Installation Year 1950
Manufactured Year 1950
Material Involved Carbon Steel
Release Type Leak
Leak Type Crack
Class Location Type Class 3 Location
Could Be Hca No
Pir Radius 253
Heat Damage Ind No
Non Heat Damage Ind No
Hca Fatalities Ind No
Est Cost Oper Paid 2500
Est Cost Unintentional Release 200
Est Cost Intentional Release 5532
Est Cost Prop Damage 50000
Est Cost Emergency 0
Est Cost Other 0
Prpty 58232
Accident Psig 744
Mop Psig 823
Mop Cfr Section Not On Omb-Approved Form When Submitted View CFR 49 §192
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 28224
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Ground Patrol By Operator Or Its Contractor
Operator Type Contractor Working For The Operator
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The gas loss was so insignificant that scada would not be able to detect it.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Pwjf Failure Type Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Field Exam Ind Yes
Metallurgical Ind Yes
Other Factor Yes
Other Factor Details Undetermined
Additional Lack Fusion Ind Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Axial Recent Year 2004
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1994
Hydrtst Most Rcnt Pressure 1260
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name D***** T**********
Preparer Title Principal Engineer
Preparer Email D************@s************.com
Preparer Telephone 713-627-5573
Preparer Fax 713-386-4468
Authorizer Name R*** K*****
Authorizer Title Director Of Operational Compliance
Authorizer Telephone 713-627-6388
Authorizer Email R*******@s************.com
Narrative A small leak was detected on east tennessee natural gas line 3200-1 during a routine instrumented leak survey. The leak originated at the pipe weld seam. The leaking pipe was removed and a metallurgical analysis was performed. The metallurgical analysis determined the leak was the result of lack of fusion in the pipe weld seam.