GD incident on 2010-06-23 — VA
Operator
Columbia Gas Of Virginia Inc
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$48,936
Incident datetime
2010-06-23 12:49
Report number
Location
VA, PITTSYLVANIA
Narrative
On june 23, 2010 at approximately 12:30 p.M. Michel's corporation struck a columbia gas of virginia (cgv) 4" weld treated high pressure (400 psig) pipeline while excavating perpendicular to the facility. As a result, service was lost downstream to four (4) residential and one (1) industrial customer for 37 1/2 hours. Crews worked continuously until repairs were made and service fully restored on 6/25/10 at 4:10 a.M. Upon investigation it is concluded that michel's corporation had a valid one call miss utility of virginia locate ticket #b016000098 for the area of excavation. This locate request was performed by consolidated utility services on 6/11/10. Ultimately locate ticket #b016000098 was cleared in the miss utility of virginia positive response system with a disposition of "10" or "marked". Further investigation revealed that although consolidated utility services cleared or coded ticket #b016000098 it did not mark the entire parameter of the ticket as requested by the excavator. As a result michel's corporation proceeded to excavate within the scope of the ticket, but beyond the bounds of the locate markings placed by consolidated utility services, which ultimately resulted in damage to cgv's pipeline.
Detailed record list
Occurred At
2010-06-23 12:49:00
Year
2010
Report Received Date
2010-07-21 00:00:00
Iyear
2010.0
Report Number
20100058.0
Supplemental Number
15074.0
Report Type
Original
Operator Id
2604
Name
Columbia Gas Of Virginia Inc
Operator Street Address
1809 Coyote Drive
Operator City Name
Chester
Operator State Abbreviation
VA
Operator Postal Code
23836
Local Datetime
2010-06-23 12:30:00
Location Street Address
Rt. 29 Bypass
Location City Name
Danville
Location County Name
Pittsylvania
Location State Abbreviation
VA
Location Postal Code
24540
Location Latitude
36.64449
Location Longitude
-79.36426
Nrc Rpt Datetime
2010-06-23 22:24:00
Nrc Rpt Num
945242
Commodity Released Type
Natural Gas
Unintentional Release
536.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2010-06-23 12:49:00
On Site Datetime
2010-06-23 13:20:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36.0
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
1992.0
Pipe Diameter
4.0
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Unknown
Wt Steel
0.237
Release Type
Other
Release Type Details
Pipe Pulled From Welded Fitting.
Class Location Type
Class 1 Location
Est Cost Prop Damage
48936.0
Est Cost Unintentional Release
2990.0
Prpty
51926.0
Commercial Affected
0.0
Industrial Affected
1.0
Residences Affected
4.0
Accident Psig
400.0
Normal Psig
400.0
Mop Psig
800.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
3rd party damage
Employee Drug Test Ind
No
Contractor Drug Test Ind
Yes
Num Contractors Tested
1
Num Contractors Failed
0
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
Notify Cga Dirt
No
Public Row Ind
Yes
Public Subtype
State Highway
Excavator Type
Contractor
Excavator Equipment
Trencher
Work Performed
Telecommunications
One Call Notified Ind
Yes
One Call Ticket Num
16000098
One Call Center Name
Virginia Utility Protection Service ( Vups )
Locator Type
Contract Locator
Visible Marks
No
Service Interruption
Yes
Service Interruption Hours
37.0
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Incomplete Marks At Damage Location
Preparer Name
T****** B*****
Preparer Title
Operations Compliance Manager
Preparer Email
T******@n*******.com
Preparer Telephone
804-768-6404
Preparer Fax
804-768-5913
Authorizer Name
T****** B*****
Authorizer Title
Operations Compliance Manager
Authorizer Telephone
804-768-6450
Authorizer Email
T******@n*******.com
Narrative
On june 23, 2010 at approximately 12:30 p.M. Michel's corporation struck a columbia gas of virginia (cgv) 4" weld treated high pressure (400 psig) pipeline while excavating perpendicular to the facility. As a result, service was lost downstream to four (4) residential and one (1) industrial customer for 37 1/2 hours. Crews worked continuously until repairs were made and service fully restored on 6/25/10 at 4:10 a.M. Upon investigation it is concluded that michel's corporation had a valid one call miss utility of virginia locate ticket #b016000098 for the area of excavation. This locate request was performed by consolidated utility services on 6/11/10. Ultimately locate ticket #b016000098 was cleared in the miss utility of virginia positive response system with a disposition of "10" or "marked". Further investigation revealed that although consolidated utility services cleared or coded ticket #b016000098 it did not mark the entire parameter of the ticket as requested by the excavator. As a result michel's corporation proceeded to excavate within the scope of the ticket, but beyond the bounds of the locate markings placed by consolidated utility services, which ultimately resulted in damage to cgv's pipeline.
| Occurred At | 2010-06-23 12:49:00 |
|---|---|
| Year | 2010 |
| Report Received Date | 2010-07-21 00:00:00 |
| Iyear | 2010.0 |
| Report Number | 20100058.0 |
| Supplemental Number | 15074.0 |
| Report Type | Original |
| Operator Id | 2604 PHMSA Enforcement |
| Name | Columbia Gas Of Virginia Inc |
| Operator Street Address | 1809 Coyote Drive |
| Operator City Name | Chester |
| Operator State Abbreviation | VA |
| Operator Postal Code | 23836 |
| Local Datetime | 2010-06-23 12:30:00 |
| Location Street Address | Rt. 29 Bypass |
| Location City Name | Danville |
| Location County Name | Pittsylvania |
| Location State Abbreviation | VA |
| Location Postal Code | 24540 |
| Location Latitude | 36.64449 Google Maps OpenStreetMap |
| Location Longitude | -79.36426 Google Maps OpenStreetMap |
| Nrc Rpt Datetime | 2010-06-23 22:24:00 |
| Nrc Rpt Num | 945242 NRC Report How to search |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 536.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2010-06-23 12:49:00 |
| On Site Datetime | 2010-06-23 13:20:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 36.0 |
| Crossing | Yes |
| Road Crossing Ind | Yes |
| Road Type | Uncased |
| Pipe Facility Type | Privately Owned |
| System Part Involved | Main |
| Installation Year | 1992.0 |
| Pipe Diameter | 4.0 |
| Pipe Specification | Unknown |
| Pipe Manufacturer | Unknown |
| Material Involved | Steel |
| Steel Seam Type | Other |
| Steel Seam Type Details | Unknown |
| Wt Steel | 0.237 |
| Release Type | Other |
| Release Type Details | Pipe Pulled From Welded Fitting. |
| Class Location Type | Class 1 Location |
| Est Cost Prop Damage | 48936.0 |
| Est Cost Unintentional Release | 2990.0 |
| Prpty | 51926.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 1.0 |
| Residences Affected | 4.0 |
| Accident Psig | 400.0 |
| Normal Psig | 400.0 |
| Mop Psig | 800.0 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | Yes |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | 3rd party damage |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | Yes |
| Num Contractors Tested | 1 |
| Num Contractors Failed | 0 |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | Yes |
| One Call System Ind | Yes |
| Notify Cga Dirt | No |
| Public Row Ind | Yes |
| Public Subtype | State Highway |
| Excavator Type | Contractor |
| Excavator Equipment | Trencher |
| Work Performed | Telecommunications |
| One Call Notified Ind | Yes |
| One Call Ticket Num | 16000098 |
| One Call Center Name | Virginia Utility Protection Service ( Vups ) |
| Locator Type | Contract Locator |
| Visible Marks | No |
| Service Interruption | Yes |
| Service Interruption Hours | 37.0 |
| Root Cause Category | Locating Issue |
| Root Cause Type | Facility Not Marked Due To Incomplete Marks At Damage Location |
| Preparer Name | T****** B***** |
| Preparer Title | Operations Compliance Manager |
| Preparer Email | T******@n*******.com |
| Preparer Telephone | 804-768-6404 |
| Preparer Fax | 804-768-5913 |
| Authorizer Name | T****** B***** |
| Authorizer Title | Operations Compliance Manager |
| Authorizer Telephone | 804-768-6450 |
| Authorizer Email | T******@n*******.com |
| Narrative | On june 23, 2010 at approximately 12:30 p.M. Michel's corporation struck a columbia gas of virginia (cgv) 4" weld treated high pressure (400 psig) pipeline while excavating perpendicular to the facility. As a result, service was lost downstream to four (4) residential and one (1) industrial customer for 37 1/2 hours. Crews worked continuously until repairs were made and service fully restored on 6/25/10 at 4:10 a.M. Upon investigation it is concluded that michel's corporation had a valid one call miss utility of virginia locate ticket #b016000098 for the area of excavation. This locate request was performed by consolidated utility services on 6/11/10. Ultimately locate ticket #b016000098 was cleared in the miss utility of virginia positive response system with a disposition of "10" or "marked". Further investigation revealed that although consolidated utility services cleared or coded ticket #b016000098 it did not mark the entire parameter of the ticket as requested by the excavator. As a result michel's corporation proceeded to excavate within the scope of the ticket, but beyond the bounds of the locate markings placed by consolidated utility services, which ultimately resulted in damage to cgv's pipeline. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA