GD incident on 2010-04-12 — KY

Operator
Louisville Gas & Electric Co
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2010-04-12 17:07
Report number
Location
KY, JEFFERSON
Narrative

No narrative available.

Detailed record list
Occurred At
2010-04-12 17:07:00
Year
2010
Report Received Date
2010-05-12 00:00:00
Iyear
2010.0
Report Number
20100026.0
Supplemental Number
15199.0
Report Type
Supplemental Final
Operator Id
Name
Louisville Gas & Electric Co
Operator Street Address
820 West Broadway, Po Box 32030
Operator City Name
Louisville
Operator State Abbreviation
KY
Operator Postal Code
40202
Local Datetime
2010-04-12 16:20:00
Location Street Address
10220 Saddle Pointe Drive
Location City Name
Louisville
Location County Name
Jefferson
Location State Abbreviation
KY
Location Postal Code
40291
Location Latitude
Location Longitude
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
16.95
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Explode Ind
No
Incident Identified Datetime
2010-04-12 17:07:00
On Site Datetime
2010-04-12 17:33:00
Federal
No
Location Type
Private Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Outside Meter/regulator Set
Installation Year
1998.0
Material Involved
Other
Material Details
Aluminum Meter
Release Type
Other
Release Type Details
Falling Debris From Ongoing Residential Structure Fire Struck The Meter And Regulator, Damaging The Facilities And Igniting Natural Gas.
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
0.0
Est Cost Emergency
200.0
Est Cost Other
0.0
Est Cost Unintentional Release
95.0
Prpty
295.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Accident Psig
60.0
Normal Psig
52.47
Mop Psig
60.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Nearby Industrial, Man-Made, Or Other Fire/explosion As Primary Cause Of Incident
Outside Force Type
Nearby Industrial, Man-Made, Or Other Fire/explosion As Primary Cause Of Incident
Preparer Name
J** D****
Preparer Title
Sr. Corporate Attorney
Preparer Email
J********@l*****.com
Preparer Telephone
5026273712
Preparer Fax
5026273367
Authorizer Name
J** D****
Authorizer Title
Sr. Corporate Attorney
Authorizer Telephone
5026273712
Authorizer Email
J********@l*****.com
Occurred At 2010-04-12 17:07:00
Year 2010
Report Received Date 2010-05-12 00:00:00
Iyear 2010.0
Report Number 20100026.0
Supplemental Number 15199.0
Report Type Supplemental Final
Operator Id 11824 PHMSA Enforcement
Name Louisville Gas & Electric Co
Operator Street Address 820 West Broadway, Po Box 32030
Operator City Name Louisville
Operator State Abbreviation KY
Operator Postal Code 40202
Local Datetime 2010-04-12 16:20:00
Location Street Address 10220 Saddle Pointe Drive
Location City Name Louisville
Location County Name Jefferson
Location State Abbreviation KY
Location Postal Code 40291
Location Latitude 38.0964 Google Maps OpenStreetMap
Location Longitude -85.58459 Google Maps OpenStreetMap
Nrc Rpt Num 936857 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 16.95
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
Explode Ind No
Incident Identified Datetime 2010-04-12 17:07:00
On Site Datetime 2010-04-12 17:33:00
Federal No
Location Type Private Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing No
Pipe Facility Type Privately Owned
System Part Involved Outside Meter/regulator Set
Installation Year 1998.0
Material Involved Other
Material Details Aluminum Meter
Release Type Other
Release Type Details Falling Debris From Ongoing Residential Structure Fire Struck The Meter And Regulator, Damaging The Facilities And Igniting Natural Gas.
Class Location Type Class 3 Location
Est Cost Oper Paid 0.0
Est Cost Prop Damage 0.0
Est Cost Emergency 200.0
Est Cost Other 0.0
Est Cost Unintentional Release 95.0
Prpty 295.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 1.0
Accident Psig 60.0
Normal Psig 52.47
Mop Psig 60.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Other Outside Force Damage
Cause Details Nearby Industrial, Man-Made, Or Other Fire/explosion As Primary Cause Of Incident
Outside Force Type Nearby Industrial, Man-Made, Or Other Fire/explosion As Primary Cause Of Incident
Preparer Name J** D****
Preparer Title Sr. Corporate Attorney
Preparer Email J********@l*****.com
Preparer Telephone 5026273712
Preparer Fax 5026273367
Authorizer Name J** D****
Authorizer Title Sr. Corporate Attorney
Authorizer Telephone 5026273712
Authorizer Email J********@l*****.com

All rights reserved. Copyright © by ClearPHMSA